These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
523 related articles for article (PubMed ID: 19928514)
1. [One case of the basilar invagination that prevented tracheal intubation by Airway Scope]. Kitai Y; Shizukuishi M; Fukuda I; Kazama T Masui; 2009 Nov; 58(11):1437-40. PubMed ID: 19928514 [TBL] [Abstract][Full Text] [Related]
2. Tracheal intubation by non-anesthesia residents using the Pentax-AWS airway scope and Macintosh laryngoscope. Hirabayashi Y; Seo N J Clin Anesth; 2009 Jun; 21(4):268-71. PubMed ID: 19502032 [TBL] [Abstract][Full Text] [Related]
3. [Use of a gum elastic bougie for tracheal intubation with Pentax-AWS airway scope]. Ueshima H; Asai T; Shingu K; Inoue H; Hashimoto Y; Enomoto Y; Okuda Y Masui; 2008 Jan; 57(1):82-4. PubMed ID: 18214009 [TBL] [Abstract][Full Text] [Related]
4. The Pentax-AWS((R)) rigid indirect video laryngoscope: clinical assessment of performance in 320 cases. Suzuki A; Toyama Y; Katsumi N; Kunisawa T; Sasaki R; Hirota K; Henderson JJ; Iwasaki H Anaesthesia; 2008 Jun; 63(6):641-7. PubMed ID: 18477277 [TBL] [Abstract][Full Text] [Related]
5. Evaluation of the Airway Scope, a new video laryngoscope, in tracheal intubation by naive operators: a manikin study. Miki T; Inagawa G; Kikuchi T; Koyama Y; Goto T Acta Anaesthesiol Scand; 2007 Nov; 51(10):1378-81. PubMed ID: 17944642 [TBL] [Abstract][Full Text] [Related]
6. [Successful nasal intubation using airway scope with gum elastic bougie in a case of difficult airway]. Inoue H; Saito T; Kamishima K; Okano T; Kuno Y; Arai T; Okuda Y Masui; 2008 Apr; 57(4):457-9. PubMed ID: 18416204 [TBL] [Abstract][Full Text] [Related]
8. Utility of the Pentax-AWS without interruption of chest compression: comparison of the Macintosh laryngoscope with the Pentax-AWS in manikin model. Han SK; Shin DH; Choi PC Resuscitation; 2010 Jan; 81(1):69-73. PubMed ID: 19919888 [TBL] [Abstract][Full Text] [Related]
9. [Usability of AirWay Scope for awake tracheal intubation in a burn patient with difficult airway]. Kato T; Kusunoki S; Kawamoto M; Yuge O Masui; 2007 Oct; 56(10):1179-81. PubMed ID: 17966622 [TBL] [Abstract][Full Text] [Related]
10. Tracheal intubation of a difficult airway using Airway Scope, Airtraq, and Macintosh laryngoscope: a comparative manikin study of inexperienced personnel. Liu L; Tanigawa K; Kusunoki S; Tamura T; Ota K; Yamaga S; Kida Y; Otani T; Sadamori T; Takeda T; Iwasaki Y; Hirohashi N Anesth Analg; 2010 Apr; 110(4):1049-55. PubMed ID: 20357149 [TBL] [Abstract][Full Text] [Related]
11. Tracheal intubation with the PENTAX-AWS (airway scope) reduces changes of hemodynamic responses and bispectral index scores compared with the Macintosh laryngoscope. Nishikawa K; Matsuoka H; Saito S J Neurosurg Anesthesiol; 2009 Oct; 21(4):292-6. PubMed ID: 19955890 [TBL] [Abstract][Full Text] [Related]
12. [Difficult tracheal intubation using airway scope in a pediatric patient with Hunter syndrome]. Taguchi S; Kusunoki S; Fukuda H; Hamada H; Kawamoto M Masui; 2009 Oct; 58(10):1278-81. PubMed ID: 19860233 [TBL] [Abstract][Full Text] [Related]
13. [Tracheal intubation with Pentax AWS Airway Scope after failed fiberoptic intubation and failed insertion of the intubating laryngeal mask airway]. Asai T; Ito I; Kuremoto Y; Kawashima A Masui; 2010 Apr; 59(4):470-2. PubMed ID: 20420136 [TBL] [Abstract][Full Text] [Related]
14. [Combined use of the airway scope and fiberoptic bronchoscopy for tracheal intubation in a patient with a large epiglottic cyst]. Satoi A; Murao K; Inoue S; Kambara T; Jomura S; Nakao M; Shingu K Masui; 2009 Aug; 58(8):1028-31. PubMed ID: 19702226 [TBL] [Abstract][Full Text] [Related]
15. [Use of the Pentax-AWS videolaryngoscope for bougie-assisted exchange of tracheal tubes]. Kishii M; Asai T; Nagata A; Shingu K Masui; 2009 Jun; 58(6):765-7. PubMed ID: 19522274 [TBL] [Abstract][Full Text] [Related]
16. [Endotracheal intubation for a neonatal patient complicated with Arnold-Chiari malformation using a Pentax airway scope with a neonatal-type INTLOCK blade (ITL-N)]. Hoshijima H; Takeuchi R; Imamura T; Iwase Y; Nagasaka H; Matsumoto N Masui; 2013 Apr; 62(4):435-8. PubMed ID: 23697196 [TBL] [Abstract][Full Text] [Related]
17. The Pentax-AWS video-laryngoscope: the first experience in one hundred patients. Asai T; Enomoto Y; Shimizu K; Shingu K; Okuda Y Anesth Analg; 2008 Jan; 106(1):257-9, table of contents. PubMed ID: 18165587 [TBL] [Abstract][Full Text] [Related]
18. [Esophageal intubation: Can it be avoided with the airway scope (Pentax-AWS)?]. Suzuki A; Yamagishi A; Sasakawa T; Kunisawa T; Takahata O; Iwasaki H Masui; 2008 Sep; 57(9):1160-3. PubMed ID: 18807908 [TBL] [Abstract][Full Text] [Related]
19. [Case report of endotracheal intubation using AirWay Scope (Pentax-AWS) in a Forestier's disease patient]. Shinohara T; Taga N; Hirabayashi Y; Seo N Masui; 2011 Feb; 60(2):186-8. PubMed ID: 21384652 [TBL] [Abstract][Full Text] [Related]
20. [Pentax-AWS improves laryngeal view compared with Macintosh blade during laryngoscopy and facilitates easier intubation]. Suzuki A; Toyama Y; Katsumi N; Sasaki R; Hirota K; Matsumoto H; Takahata O; Iwasaki H Masui; 2007 Apr; 56(4):464-8. PubMed ID: 17441461 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]