These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
81 related articles for article (PubMed ID: 1992982)
1. Cold-induced granulocyte agglutination. A cause of pseudoleukopenia. Robbins SH; Conly MA; Oettinger J Arch Pathol Lab Med; 1991 Feb; 115(2):155-7. PubMed ID: 1992982 [TBL] [Abstract][Full Text] [Related]
2. Four cases of spuriously low WBC count due to in vitro leukocyte agglutination: contribution of the hematology analyzer Coulter STKS in detecting this clinically misleading artefact. Vinatier I; Capiod JC; Sassier P; Roussel B; Delobel J Pathol Biol (Paris); 1994 Oct; 42(8):775-80. PubMed ID: 7724249 [TBL] [Abstract][Full Text] [Related]
3. Spurious automated leukopenia due to in vitro granulocyte aggregation. Rohr LR; Rivers FM Am J Clin Pathol; 1990 Apr; 93(4):572-4. PubMed ID: 2321589 [TBL] [Abstract][Full Text] [Related]
4. [Temperature-dependent pseudoleukocytopenia and in vitro studies on the underlying mechanism]. Tsuda T; Fujii M; Shimizu E; Tsujimoto M; Okamoto Y; Ota K; Maeda J Rinsho Ketsueki; 1990 Jan; 31(1):23-8. PubMed ID: 2107345 [TBL] [Abstract][Full Text] [Related]
5. Instrumental reports and effect of anticoagulants in a case of neutrophil agglutination in vitro. Galifi M; Schinella M; Nicoli M; Lippi G Haematologica; 1993; 78(6):364-70. PubMed ID: 7503816 [TBL] [Abstract][Full Text] [Related]
6. Effects of a 99mTc-labeled murine immunoglobulin M antibody to CD15 antigens on human granulocyte membranes in healthy volunteers. Mozley PD; Thakur ML; Alavi A; Smith T; Barraclough ED; Wilding P; Rhodes BA; Patel M; Mathur A; Li P J Nucl Med; 1999 Dec; 40(12):2107-14. PubMed ID: 10616893 [TBL] [Abstract][Full Text] [Related]
7. Automated five-part white blood cell differential counts. Efficiency of software-generated white blood cell suspect flags of the hematology analyzers Sysmex SE-9000, Sysmex NE-8000, and Coulter STKS. Thalhammer-Scherrer R; Knöbl P; Korninger L; Schwarzinger I Arch Pathol Lab Med; 1997 Jun; 121(6):573-7. PubMed ID: 9199621 [TBL] [Abstract][Full Text] [Related]
8. EDTA-temperature-Induced pseudohematocytopenia in a patient with multiple myeloma. Zhang L; Pan S; Zhang J; Lu L; Xie E; Ye Q Clin Lab; 2012; 58(5-6):563-5. PubMed ID: 22783589 [TBL] [Abstract][Full Text] [Related]
9. Granulocyte aggregation is edetic acid and temperature dependent. Bizzaro N Arch Pathol Lab Med; 1993 May; 117(5):528-30. PubMed ID: 8489344 [TBL] [Abstract][Full Text] [Related]
10. Abnormal leukocyte histogram with a factitious automated white cell count due to Plasmodium vivax parasitemia--a case report. Kakkar N; Guliani S Indian J Pathol Microbiol; 2003 Oct; 46(4):666-7. PubMed ID: 15025375 [TBL] [Abstract][Full Text] [Related]
11. [Pseudoleucopenia due to in vitro leukocyte agglutination polynuclear neutrophils: experience of a laboratory, review of the literature and future management]. Lesesve JF; Haristoy X; Thouvenin M; Latger-Cannard V; Buisine J; Lecompte T Ann Biol Clin (Paris); 2000; 58(4):417-24. PubMed ID: 10932041 [TBL] [Abstract][Full Text] [Related]
12. In Vitro Leukoagglutination: A Rare Hematological Cause of Spurious Leukopenia. Sultan S; Irfan SM Acta Med Iran; 2017 Jun; 55(6):408-410. PubMed ID: 28843244 [TBL] [Abstract][Full Text] [Related]
14. Effects of bacteria and yeast on WBC counting in three automated hematology counters. Kim HR; Park BR; Lee MK Ann Hematol; 2008 Jul; 87(7):557-62. PubMed ID: 18301891 [TBL] [Abstract][Full Text] [Related]
15. Pseudopolycythemia, pseudothrombocytopenia, and pseudoleukopenia due to overfilling of blood collection vacuum tubes. Pewarchuk W; VanderBoom J; Blajchman MA Arch Pathol Lab Med; 1992 Jan; 116(1):90-2. PubMed ID: 1734839 [TBL] [Abstract][Full Text] [Related]
16. Transient granulocyte maturation arrest: discovery by flow cytometry of a variant form of agranulocytosis. Ross DW; Pryzwansky KB Am J Pediatr Hematol Oncol; 1985; 7(1):91-6. PubMed ID: 4037247 [TBL] [Abstract][Full Text] [Related]
17. Peripheral blood candidosis infection leading to spurious platelet and white blood cell counts. Lesesve JF; Khalifa MA; Denoyes R; Braun F Int J Lab Hematol; 2009 Oct; 31(5):572-6. PubMed ID: 18498388 [TBL] [Abstract][Full Text] [Related]
18. Evaluation of the Beckman Coulter AcT 5 diff AL hematology analyzer in a hospital setting. Bhuta UM; Ulstein H Lab Hematol; 2003; 9(3):167-74. PubMed ID: 14521325 [TBL] [Abstract][Full Text] [Related]
19. Granulocyte- and monocyte-platelet adhesion index in coronary and peripheral blood after extracorporeal circulation and reperfusion. Sbrana S; Buffa M; Bevilacqua S; Spiller D; Parri MS; Gianetti J; De Filippis R; Clerico A Cytometry B Clin Cytom; 2007 May; 72(3):215-22. PubMed ID: 17133378 [TBL] [Abstract][Full Text] [Related]
20. Immature granulocyte measurement using the Sysmex XE-2100. Relationship to infection and sepsis. Ansari-Lari MA; Kickler TS; Borowitz MJ Am J Clin Pathol; 2003 Nov; 120(5):795-9. PubMed ID: 14608908 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]