  • 21. Effects of heating rate and dose on trapping parameters of TLD-100 crystals.
    Caprile PF; Sánchez-Nieto B; Pino AM; Delgado JF
    Health Phys; 2013 Feb; 104(2):218-23. PubMed ID: 23274825
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Phenomenological study of the ionisation density-dependence of TLD-100 peak 5a.
    Brandan ME; Angeles O; Mercado-Uribe H
    Radiat Prot Dosimetry; 2006; 119(1-4):29-32. PubMed ID: 16785244
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Advanced multistage deconvolution applied to composite glow peak 5 in LiF:Mg,Ti (TLD-100).
    Horowitz YS; Fuks E; Oster L; Podpalov L; Belaish Y; Shachar BB
    Radiat Prot Dosimetry; 2007; 126(1-4):322-5. PubMed ID: 17517677
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Glow curve analysis of composite peak 5 in LiF:Mg,Ti (TLD-100) using optical bleaching, thermal annealing and computerised glow curve deconvolution.
    Biderman S; Horowitz YS; Oster L; Einav Y; Dubi Y
    Radiat Prot Dosimetry; 2002; 101(1-4):69-72. PubMed ID: 12382707
    [TBL] [Abstract][Full Text] [Related]  

  • 25. THE UNIFIED INTERACTION MODEL: SIMULATIONS OF TL DOSE RESPONSE AND EXPERIMENTAL VERIFICATION OF INTENDED DOSE RESPONSE LINEARITY BY POSTIRRADIATION PHOTON EXCITATION.
    Ginzburg D; Oster L; Biderman S; Reshes G; Eliyahu I
    Radiat Prot Dosimetry; 2020 Dec; 192(2):152-164. PubMed ID: 33415338
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Study of real time temperature profiles in routine TLD read out--influences of detector thickness and heating rate on glow curve shape.
    Stadtmann H; Hranitzky C; Brasik N
    Radiat Prot Dosimetry; 2006; 119(1-4):310-3. PubMed ID: 16825249
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Localised and delocalised optically induced conversion of composite glow peak 5 in LiF:Mg,Ti (TLD-100) to glow peak 4 as a function of postirradiation annealing temperature.
    Horowitz YS; Einav Y; Biderman S; Oster L
    Radiat Prot Dosimetry; 2002; 100(1-4):135-8. PubMed ID: 12382846
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Investigation of the ionisation density dependence of the glow curve characteristics of LIF:MG,TI (TLD-100).
    Horowitz YS; Horowitz A; Oster L; Marino S; Datz H; Margaliot M
    Radiat Prot Dosimetry; 2008; 131(4):406-13. PubMed ID: 18667402
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Optical excitation of LiF:Mg,Ti following alpha and beta irradiation.
    Horowitz YS; Fuks Y; Weiss D; Oster L; Podpalov L; Belaish Y
    Radiat Prot Dosimetry; 2006; 119(1-4):386-9. PubMed ID: 16585263
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Impact of reading pre-irradiation background signal on the post-irradiation glow curves of thermoluminescence dosimeters.
    Abd El-Hafez AI; Maghraby A
    Appl Radiat Isot; 2011 Oct; 69(10):1533-9. PubMed ID: 21724407
    [TBL] [Abstract][Full Text] [Related]  

  • 31. A comparative study on the susceptibility of LiF:Mg,Ti (TLD-100) and LiF:Mg,Cu,P (TLD-100H) to spurious signals in thermoluminescence dosimetry.
    Al-Haj A; Lagarde C; Mahyoub F
    Radiat Prot Dosimetry; 2007; 125(1-4):399-402. PubMed ID: 17223633
    [TBL] [Abstract][Full Text] [Related]  

  • 32. The composite structure of peak 5 in the glow curve of LiF:Mg,Ti (TLD-100): confirmation of peak 5a arising from a locally trapped electron-hole configuration.
    Horowitz YS; Oster L; Satinger D; Biderman S; Einav Y
    Radiat Prot Dosimetry; 2002; 100(1-4):123-6. PubMed ID: 12382843
    [TBL] [Abstract][Full Text] [Related]  

  • 33. MANIPULATION OF THE DOSE-RESPONSE OF COMPOSITE GLOW PEAK 5 IN THE THERMOLUMINESCENCE OF LiF:Mg,Ti (TLD-100) VIA OPTICAL EXCITATION POST-IRRADIATION: POTENTIAL FOR IMPROVED DOSE-RESPONSE LINEARITY BEYOND 1 Gy.
    Ginzburg D; Oster L; Eliyahu I; Reshes G; Biderman S; Horowitz YS
    Radiat Prot Dosimetry; 2019 Aug; 184(2):248-255. PubMed ID: 30508125
    [TBL] [Abstract][Full Text] [Related]  

  • 34. On the use of LiF TLD-600 in neutron-gamma mixed fields.
    Delgado A; Muñiz JL; Gómez Ros JM; Romero AM; Rodríguez R
    Radiat Prot Dosimetry; 2007; 125(1-4):327-30. PubMed ID: 17578870
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Comments to the author's response to our letter on "The thermoluminescence dose-response and other characteristics of the high-temperature TL in LiF:Mg,Ti (TLD-100)" by Y.S. Horowitz, L. Oster and H. Datz.
    German U; Weinstein M; Abraham A; Alfassi ZB
    Radiat Prot Dosimetry; 2008; 129(4):495-7; author reply 497. PubMed ID: 18650206
    [No Abstract]   [Full Text] [Related]  

  • 36. Kinetic modelling of the optically stimulated conversion of peaks 5a and 5 to peak 4 in LiF:Mg,Ti (TLD-100).
    Weizman Y; Horowitz YS; Oster L
    Radiat Prot Dosimetry; 2002; 100(1-4):131-4. PubMed ID: 12382845
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Comments on 'The thermoluminescence dose-response and other characteristics of the high-temperature TL in LiF: Mg.Ti (TLD-100)' by Y.S. Horowitz, L. Oster and H. Datz.
    German U; Weinstein M; Abraham A; Alfassi ZB
    Radiat Prot Dosimetry; 2008; 128(4):509-10; author reply 510-5. PubMed ID: 18420571
    [No Abstract]   [Full Text] [Related]  

  • 38. The effects of ionisation density on the thermoluminescence response (efficiency) of LiF:Mg,Ti and LiF:Mg,Cu,P.
    Horowitz Y; Olko P
    Radiat Prot Dosimetry; 2004; 109(4):331-48. PubMed ID: 15273352
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Alpha particle and proton relative thermoluminescence efficiencies in LiF:Mg,Cu,P:is track structure theory up to the task?
    Horowitz YS; Siboni D; Oster L; Livingstone J; Guatelli S; Rosenfeld A; Emfietzoglou D; Bilski P; Obryk B
    Radiat Prot Dosimetry; 2012 Jul; 150(3):359-74. PubMed ID: 22042968
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Glow curve analysis applied to the discrimination of X ray versus proton irradiation.
    Skopec M; Price JL; Guardala N; Loew M; Moscovitch M
    Radiat Prot Dosimetry; 2002; 101(1-4):99-102. PubMed ID: 12382714
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]