These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

189 related articles for article (PubMed ID: 19936528)

  • 21. Effect of surface area ratios and bacteria on electrochemical behavior of galvanically coupled titanium.
    Koh I; Oshida Y; Andres CJ; Gregory RL
    Int J Prosthodont; 2008; 21(5):433-6. PubMed ID: 18950067
    [TBL] [Abstract][Full Text] [Related]  

  • 22. The effect of Electro Discharge Machining (EDM) on the corrosion resistance of dental alloys.
    Ntasi A; Mueller WD; Eliades G; Zinelis S
    Dent Mater; 2010 Dec; 26(12):e237-45. PubMed ID: 20832106
    [TBL] [Abstract][Full Text] [Related]  

  • 23. [Effect of pH value and fluoride ions on corrosion resistance of pure Ti and Ni-Cr-Ti alloy in artificial saliva].
    Liang BG; Shen XT; Liu L; Lü YX; Yu ZD; Yang CX; Zhang YZ
    Zhejiang Da Xue Xue Bao Yi Xue Ban; 2010 Jul; 39(4):399-403. PubMed ID: 20731040
    [TBL] [Abstract][Full Text] [Related]  

  • 24. [Corrosion property and oxide film of dental casting alloys before and after porcelain firing].
    Ma Q; Wu FM
    Zhonghua Kou Qiang Yi Xue Za Zhi; 2011 Mar; 46(3):172-6. PubMed ID: 21575441
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Electrochemical behavior of titanium in artificial saliva: influence of pH.
    Abey S; Mathew MT; Lee DJ; Knoernschild KL; Wimmer MA; Sukotjo C
    J Oral Implantol; 2014 Feb; 40(1):3-10. PubMed ID: 22103963
    [TBL] [Abstract][Full Text] [Related]  

  • 26. The electrochemical behavior and surface analysis of Ti50Ni47.2Co2.8 alloy for orthodontic use.
    Wang QY; Zheng YF
    Dent Mater; 2008 Sep; 24(9):1207-11. PubMed ID: 18336899
    [TBL] [Abstract][Full Text] [Related]  

  • 27. The castability of pure titanium compared with Ni-Cr and Ni-Cr-Be alloys.
    Paulino SM; Leal MB; Pagnano VO; Bezzon OL
    J Prosthet Dent; 2007 Dec; 98(6):445-54. PubMed ID: 18061738
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Surface and elemental alterations of dental alloys induced by electro discharge machining (EDM).
    Zinelis S
    Dent Mater; 2007 May; 23(5):601-7. PubMed ID: 16846638
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Potentiodynamic polarization study of the corrosion behavior of palladium-silver dental alloys.
    Sun D; Brantley WA; Frankel GS; Heshmati RH; Johnston WM
    J Prosthet Dent; 2018 Apr; 119(4):650-656. PubMed ID: 28965676
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Adhesion testing of a denture base resin with 5 casting alloys.
    Clelland NL; van Putten MC; Brantley WA; Knobloch LA
    J Prosthodont; 2000 Mar; 9(1):30-6. PubMed ID: 11074026
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Study of corrosion of combinations of titanium/Ti-6Al-4V implants and dental alloys.
    Yamazoe M
    Dent Mater J; 2010 Oct; 29(5):542-53. PubMed ID: 20823622
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Titanium alloy cylinders in implant framework fabrication: a study of the cylinder-alloy interface.
    Carr AB; Brantley WA
    J Prosthet Dent; 1993 Apr; 69(4):391-7. PubMed ID: 8463969
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Evaluation of restorative and implant alloys galvanically coupled to titanium.
    Venugopalan R; Lucas LC
    Dent Mater; 1998 Jun; 14(3):165-72. PubMed ID: 10196792
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Assessment of corrosion resistance of cast cobalt- and nickel-chromium dental alloys in acidic environments.
    Mercieca S; Caligari Conti M; Buhagiar J; Camilleri J
    J Appl Biomater Funct Mater; 2018 Jan; 16(1):47-54. PubMed ID: 29076515
    [TBL] [Abstract][Full Text] [Related]  

  • 35. In vitro corrosion resistance of high-palladium dental casting alloys.
    Cai Z; Vermilyea SG; Brantley WA
    Dent Mater; 1999 May; 15(3):202-10. PubMed ID: 10551085
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Stability of cp-Ti and Ti-6Al-4V alloy for dental implants as a function of saliva pH - an electrochemical study.
    Barão VA; Mathew MT; Assunção WG; Yuan JC; Wimmer MA; Sukotjo C
    Clin Oral Implants Res; 2012 Sep; 23(9):1055-62. PubMed ID: 22092540
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Effect of surface reaction layer on grindability of cast titanium alloys.
    Ohkubo C; Hosoi T; Ford JP; Watanabe I
    Dent Mater; 2006 Mar; 22(3):268-74. PubMed ID: 16083955
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Evaluation of titanium in oral conditions and its electrochemical corrosion behaviour.
    Canay S; Hersek N; Culha A; Bilgiç S
    J Oral Rehabil; 1998 Oct; 25(10):759-64. PubMed ID: 9802583
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Long-term assessment of the implant titanium material--artificial saliva interface.
    Popa MV; Vasilescu E; Drob P; Vasilescu C; Demetrescu I; Ionita D
    J Mater Sci Mater Med; 2008 Jan; 19(1):1-9. PubMed ID: 17990081
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Are new TiNbZr alloys potential substitutes of the Ti6Al4V alloy for dental applications? An electrochemical corrosion study.
    Ribeiro AL; Hammer P; Vaz LG; Rocha LA
    Biomed Mater; 2013 Dec; 8(6):065005. PubMed ID: 24280708
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 10.