These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

152 related articles for article (PubMed ID: 1993791)

  • 1. The automatic implantable cardioverter-defibrillator: effect of patch polarity on defibrillation threshold.
    O'Neill PG; Boahene KA; Lawrie GM; Harvill LF; Pacifico A
    J Am Coll Cardiol; 1991 Mar; 17(3):707-11. PubMed ID: 1993791
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Initial clinical experience with endocardial defibrillation using an implantable cardioverter/defibrillator with a triple-electrode system.
    Saksena S; Tullo NG; Krol RB; Mauro AM
    Arch Intern Med; 1989 Oct; 149(10):2333-9. PubMed ID: 2802898
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Successful implantation of cardioverter-defibrillator systems in patients with elevated defibrillation thresholds.
    Brooks R; Torchiana D; Vlahakes GJ; Ruskin JN; McGovern BA; Garan H
    J Am Coll Cardiol; 1993 Aug; 22(2):569-74. PubMed ID: 8335831
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [The implantable automatic cardioverter-defibrillator].
    Klein H; Tröster J; Trappe HJ; Becht I; Siclari F
    Herz; 1990 Apr; 15(2):111-25. PubMed ID: 2188891
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effect of shock polarity on ventricular defibrillation threshold using a transvenous lead system.
    Strickberger SA; Hummel JD; Horwood LE; Jentzer J; Daoud E; Niebauer M; Bakr O; Man KC; Williamson BD; Kou W
    J Am Coll Cardiol; 1994 Oct; 24(4):1069-72. PubMed ID: 7930199
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Ventricular pacing threshold and time to capture postdefibrillation in patients undergoing implantable cardioverter-defibrillator implantation.
    Khastgir T; Lattuca J; Aarons D; Murphy J; O'Mara V; Juanteguy J; Veltri EP
    Pacing Clin Electrophysiol; 1991 May; 14(5 Pt 1):768-72. PubMed ID: 1712951
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Success of chronic defibrillation and the role of antiarrhythmic drugs with the automatic implantable cardioverter/defibrillator.
    Guarnieri T; Levine JH; Veltri EP; Griffith LS; Watkins L; Juanteguy J; Mower MM; Mirowski M
    Am J Cardiol; 1987 Nov; 60(13):1061-4. PubMed ID: 3673907
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Electrode system influence on biphasic waveform defibrillation efficacy in humans.
    Bardy GH; Troutman C; Johnson G; Mehra R; Poole JE; Dolack GL; Kudenchuk PJ; Gartman DM
    Circulation; 1991 Aug; 84(2):665-71. PubMed ID: 1860210
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Management of complications associated with a first-generation endocardial defibrillation lead system for implantable cardioverter-defibrillators.
    Tullo NG; Saksena S; Krol RB; Mauro AM; Kunecz D
    Am J Cardiol; 1990 Aug; 66(4):411-5. PubMed ID: 2386116
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of defibrillation efficacy in humans using a new catheter and superior vena cava spring-left ventricular patch electrodes.
    Winkle RA; Bach SM; Mead RH; Gaudiani VA; Stinson EB; Fain ES; Schmidt P
    J Am Coll Cardiol; 1988 Feb; 11(2):365-70. PubMed ID: 3339175
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Late results of the left subcostal approach for automatic implantable cardioverter defibrillator implantation.
    O'Neill PG; Lawrie GM; Kaushik RR; Harvill LF; Pacifico A
    Am J Cardiol; 1991 Feb; 67(5):387-90. PubMed ID: 1994663
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The implanted defibrillator: relation of defibrillating lead configuration and clinical variables to defibrillation threshold.
    Troup PJ; Chapman PD; Olinger GN; Kleinman LH
    J Am Coll Cardiol; 1985 Dec; 6(6):1315-21. PubMed ID: 4067110
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Automatic implantable cardioverter-defibrillator implantation without thoracotomy using an endocardial and submuscular patch system.
    McCowan R; Maloney J; Wilkoff B; Simmons T; Khoury D; McAlister H; Morant V; Castle L
    J Am Coll Cardiol; 1991 Feb; 17(2):415-21. PubMed ID: 1991899
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Relation of the intraoperative defibrillation threshold to successful postoperative defibrillation with an automatic implantable cardioverter defibrillator.
    Marchlinski FE; Flores B; Miller JM; Gottlieb CD; Hargrove WC
    Am J Cardiol; 1988 Sep; 62(7):393-8. PubMed ID: 3414516
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A prospective, randomized evaluation of effect of ventricular fibrillation duration on defibrillation thresholds in humans.
    Bardy GH; Ivey TD; Allen M; Johnson G
    J Am Coll Cardiol; 1989 May; 13(6):1362-6. PubMed ID: 2703617
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Clinical efficacy of dual electrode systems for endocardial cardioversion of ventricular tachycardia: a prospective randomized crossover trial.
    Saksena S; An H
    Am Heart J; 1990 Jan; 119(1):15-22. PubMed ID: 2404386
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Efficacy of automatic multimodal device therapy for ventricular tachyarrhythmias as delivered by a new implantable pacing cardioverter-defibrillator. Results of a European multicenter study of 102 implants.
    Fromer M; Brachmann J; Block M; Siebels J; Hoffmann E; Almendral J; Ohm OJ; den Dulk K; Coumel P; Camm AJ
    Circulation; 1992 Aug; 86(2):363-74. PubMed ID: 1638705
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Influence of epicardial patches on defibrillation threshold with nonthoracotomy lead configurations.
    Fotuhi PC; Ideker RE; Idriss SF; Callihan RL; Walker RG; Alt EU
    Circulation; 1995 Nov; 92(10):3082-8. PubMed ID: 7586279
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A second defibrillator chest patch electrode will increase implantation rates for nonthoracotomy defibrillators.
    Solomon AJ; Swartz JF; Rodak DJ; Moore HJ; Hannan RL; Tracy CM; Fletcher RD
    Pacing Clin Electrophysiol; 1996 Sep; 19(9):1304-10. PubMed ID: 9005417
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Low-energy endocardial defibrillation using an axillary or a pectoral thoracic electrode location.
    Saksena S; DeGroot P; Krol RB; Raju R; Mathew P; Mehra R
    Circulation; 1993 Dec; 88(6):2655-60. PubMed ID: 8252676
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.