These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

176 related articles for article (PubMed ID: 19939704)

  • 1. Radiofrequency ablation of lung tumors in swine assisted by a navigation device with preprocedural volumetric planning.
    Banovac F; Cheng P; Campos-Nanez E; Kallakury B; Popa T; Wilson E; Abeledo H; Cleary K
    J Vasc Interv Radiol; 2010 Jan; 21(1):122-9. PubMed ID: 19939704
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Precision targeting of liver lesions using a novel electromagnetic navigation device in physiologic phantom and swine.
    Banovac F; Tang J; Xu S; Lindisch D; Chung HY; Levy EB; Chang T; McCullough MF; Yaniv Z; Wood BJ; Cleary K
    Med Phys; 2005 Aug; 32(8):2698-705. PubMed ID: 16193801
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Electromagnetic tracking for thermal ablation and biopsy guidance: clinical evaluation of spatial accuracy.
    Krücker J; Xu S; Glossop N; Viswanathan A; Borgert J; Schulz H; Wood BJ
    J Vasc Interv Radiol; 2007 Sep; 18(9):1141-50. PubMed ID: 17804777
    [TBL] [Abstract][Full Text] [Related]  

  • 4. An open electromagnetic tracking framework applied to targeted liver tumour ablation.
    Hinds S; Jaeger HA; Burke R; O'Sullivan B; Keane J; Trauzettel F; Marques B; Cotin S; Bird B; Leira HO; Hofstad EF; Solberg OV; Langø T; Cantillon-Murphy P
    Int J Comput Assist Radiol Surg; 2019 Sep; 14(9):1475-1484. PubMed ID: 31030387
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Treatment planning and image guidance for radiofrequency ablation of large tumors.
    Ren H; Campos-Nanez E; Yaniv Z; Banovac F; Abeledo H; Hata N; Cleary K
    IEEE J Biomed Health Inform; 2014 May; 18(3):920-8. PubMed ID: 24235279
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Real-time tracking of liver motion and deformation using a flexible needle.
    Lei P; Moeslein F; Wood BJ; Shekhar R
    Int J Comput Assist Radiol Surg; 2011 May; 6(3):435-46. PubMed ID: 20700662
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Real-time FDG PET guidance during biopsies and radiofrequency ablation using multimodality fusion with electromagnetic navigation.
    Venkatesan AM; Kadoury S; Abi-Jaoudeh N; Levy EB; Maass-Moreno R; Krücker J; Dalal S; Xu S; Glossop N; Wood BJ
    Radiology; 2011 Sep; 260(3):848-56. PubMed ID: 21734159
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Clinical utility of real-time fusion guidance for biopsy and ablation.
    Krücker J; Xu S; Venkatesan A; Locklin JK; Amalou H; Glossop N; Wood BJ
    J Vasc Interv Radiol; 2011 Apr; 22(4):515-24. PubMed ID: 21354816
    [TBL] [Abstract][Full Text] [Related]  

  • 9. CT volumetric assessment of pulmonary neoplasms after radiofrequency ablation: when to consider a second intervention?
    Nour-Eldin NE; Naguib NN; Tawfik AM; Gruber-Rouh T; Zangos S; Vogl TJ
    J Vasc Interv Radiol; 2014 Mar; 25(3):347-54. PubMed ID: 24581459
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Percutaneous radiofrequency ablation of virtual tumours in canine kidney using Global Positioning System-like technology.
    Hung AJ; Ma Y; Zehnder P; Nakamoto M; Gill IS; Ukimura O
    BJU Int; 2012 May; 109(9):1398-403. PubMed ID: 21992738
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A minimally invasive multimodality image-guided (MIMIG) system for peripheral lung cancer intervention and diagnosis.
    He T; Xue Z; Lu K; Valdivia y Alvarado M; Wong KK; Xie W; Wong ST
    Comput Med Imaging Graph; 2012 Jul; 36(5):345-55. PubMed ID: 22483054
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Image guidance of intracardiac ultrasound with fusion of pre-operative images.
    Sun Y; Kadoury S; Li Y; John M; Resnick J; Plambeck G; Liao R; Sauer F; Xu C
    Med Image Comput Comput Assist Interv; 2007; 10(Pt 1):60-7. PubMed ID: 18051044
    [TBL] [Abstract][Full Text] [Related]  

  • 13. In vivo accuracy assessment of a needle-based navigation system for CT-guided radiofrequency ablation of the liver.
    Maier-Hein L; Tekbas A; Seitel A; Pianka F; Müller SA; Satzl S; Schawo S; Radeleff B; Tetzlaff R; Franz AM; Müller-Stich BP; Wolf I; Kauczor HU; Schmied BM; Meinzer HP
    Med Phys; 2008 Dec; 35(12):5385-96. PubMed ID: 19175098
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Respiratory motion compensation by model-based catheter tracking during EP procedures.
    Brost A; Liao R; Strobel N; Hornegger J
    Med Image Anal; 2010 Oct; 14(5):695-706. PubMed ID: 20579931
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Optimal trajectories computation within regions of interest for hepatic RFA planning.
    Villard C; Baegert C; Schreck P; Soler L; Gangi A
    Med Image Comput Comput Assist Interv; 2005; 8(Pt 2):49-56. PubMed ID: 16685942
    [TBL] [Abstract][Full Text] [Related]  

  • 16. 3-D respiratory motion compensation during EP procedures by image-based 3-D lasso catheter model generation and tracking.
    Brost A; Liao R; Hornegger J; Strobel N
    Med Image Comput Comput Assist Interv; 2009; 12(Pt 1):394-401. PubMed ID: 20426012
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The efficacy of electromagnetic navigation to assist with computed tomography-guided percutaneous thermal ablation of lung tumors.
    Narsule CK; Sales Dos Santos R; Gupta A; Ebright MI; Rivas R; Daly BD; Fernando HC
    Innovations (Phila); 2012; 7(3):187-90. PubMed ID: 22885459
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Overlapping radiofrequency ablation planning and robot-assisted needle insertion for large liver tumors.
    Liu P; Qin J; Duan B; Wang Q; Tan X; Zhao B; Jonnathan PL; Chui CK; Heng PA
    Int J Med Robot; 2019 Feb; 15(1):e1952. PubMed ID: 30117266
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Stereotaxy: breaking the limits of current radiofrequency ablation techniques.
    Bale R; Widmann G; Stoffner DI
    Eur J Radiol; 2010 Jul; 75(1):32-6. PubMed ID: 20452738
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Microwave ablation of lung tumors: A probabilistic approach for simulation-based treatment planning.
    Sebek J; Taeprasartsit P; Wibowo H; Beard WL; Bortel R; Prakash P
    Med Phys; 2021 Jul; 48(7):3991-4003. PubMed ID: 33964020
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.