BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

332 related articles for article (PubMed ID: 19940342)

  • 21. Stroke volume estimation in heart failure patients using bioimpedance: a realistic simulation of the forward problem.
    Sokolovsky RE; Zlochiver S; Abboud S
    Physiol Meas; 2008 Jun; 29(6):S139-49. PubMed ID: 18544809
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Parametric EIT for monitoring cardiac stroke volume.
    Zlochiver S; Freimark D; Arad M; Adunsky A; Abboud S
    Physiol Meas; 2006 May; 27(5):S139-46. PubMed ID: 16636406
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Magnetic resonance electrical impedance tomography (MREIT) for high-resolution conductivity imaging.
    Woo EJ; Seo JK
    Physiol Meas; 2008 Oct; 29(10):R1-26. PubMed ID: 18799834
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Construction and validation of a plunge electrode array for three-dimensional determination of conductivity in the heart.
    Hooks DA; Trew ML
    IEEE Trans Biomed Eng; 2008 Feb; 55(2 Pt 1):626-35. PubMed ID: 18269998
    [TBL] [Abstract][Full Text] [Related]  

  • 25. RF tumour ablation: computer simulation and mathematical modelling of the effects of electrical and thermal conductivity.
    Lobo SM; Liu ZJ; Yu NC; Humphries S; Ahmed M; Cosman ER; Lenkinski RE; Goldberg W; Goldberg SN
    Int J Hyperthermia; 2005 May; 21(3):199-213. PubMed ID: 16019848
    [TBL] [Abstract][Full Text] [Related]  

  • 26. A direct reconstruction algorithm for electrical impedance tomography.
    Mueller JL; Siltanen S; Isaacson D
    IEEE Trans Med Imaging; 2002 Jun; 21(6):555-9. PubMed ID: 12166850
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Optimization of cardiac defibrillation by three-dimensional finite element modeling of the human thorax.
    Panescu D; Webster JG; Tompkins WJ; Stratbucker RA
    IEEE Trans Biomed Eng; 1995 Feb; 42(2):185-92. PubMed ID: 7868146
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Nonlinear conductance-volume relationship for murine conductance catheter measurement system.
    Wei CL; Valvano JW; Feldman MD; Pearce JA
    IEEE Trans Biomed Eng; 2005 Oct; 52(10):1654-61. PubMed ID: 16235651
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Impedance cardiography using band and regional electrodes in supine, sitting, and during exercise.
    Patterson RP; Wang L; Raza SB
    IEEE Trans Biomed Eng; 1991 May; 38(5):393-400. PubMed ID: 1874520
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Analytical solutions of electric potential and impedance for a multilayered spherical volume conductor excited by time-harmonic electric current source: application in brain EIT.
    Xiao C; Lei Y
    Phys Med Biol; 2005 Jun; 50(11):2663-74. PubMed ID: 15901961
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Ranking the influence of tissue conductivities on forward-calculated ECGs.
    Keller DU; Weber FM; Seemann G; Dössel O
    IEEE Trans Biomed Eng; 2010 Jul; 57(7):1568-76. PubMed ID: 20659824
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Theory and cardiac applications of electrical impedance measurements.
    Penney BC
    Crit Rev Biomed Eng; 1986; 13(3):227-81. PubMed ID: 3516573
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Electric field distribution in a finite-volume head model of deep brain stimulation.
    Grant PF; Lowery MM
    Med Eng Phys; 2009 Nov; 31(9):1095-103. PubMed ID: 19656716
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Impedance cardiography in the measurement of cardiac output: studies in rabbits.
    Pappas CG; Wang X; Connolly RJ; Schwaitzberg SD
    J Surg Res; 1995 Oct; 59(4):504-10. PubMed ID: 7564325
    [TBL] [Abstract][Full Text] [Related]  

  • 35. On the flow dependency of the electrical conductivity of blood.
    Hoetink AE; Faes TJ; Visser KR; Heethaar RM
    IEEE Trans Biomed Eng; 2004 Jul; 51(7):1251-61. PubMed ID: 15248541
    [TBL] [Abstract][Full Text] [Related]  

  • 36. A nonlinear electrical-thermal model of the skin.
    Panescu D; Webster JG; Stratbucker RA
    IEEE Trans Biomed Eng; 1994 Jul; 41(7):672-80. PubMed ID: 7927388
    [TBL] [Abstract][Full Text] [Related]  

  • 37. The effects of inhomogeneities and anisotropies on electrocardiographic fields: a 3-D finite-element study.
    Klepfer RN; Johnson CR; Macleod RS
    IEEE Trans Biomed Eng; 1997 Aug; 44(8):706-19. PubMed ID: 9254984
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Investigation of the origin of the impedance cardiogram by means of exchange transfusion with stroma free haemoglobin solution in the dog.
    Visser KR; Lamberts R; Zijlstra WG
    Cardiovasc Res; 1990 Jan; 24(1):24-32. PubMed ID: 2328511
    [TBL] [Abstract][Full Text] [Related]  

  • 39. [Noninvasive ventilatory volume monitor using the electrical impedance method--elimination of impedance changes associated with cardiac oscillations].
    Itoh A; Kikuchi N; Ishida A; Okazaki N; Kira S
    Iyodenshi To Seitai Kogaku; 1982 Sep; 20(5):314-20. PubMed ID: 7182614
    [No Abstract]   [Full Text] [Related]  

  • 40. Experimental and numerical study on optimal spot-electrodes arrays in transthoracic electrical impedance cardiography.
    Ikarashi A; Nogawa M; Tanaka S; Yamakoshi K
    Annu Int Conf IEEE Eng Med Biol Soc; 2007; 2007():4580-3. PubMed ID: 18003025
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 17.