These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

158 related articles for article (PubMed ID: 19942516)

  • 1. Very high frequency (beyond 100 MHz) PZT kerfless linear arrays.
    Wu DW; Zhou Q; Geng X; Liu CG; Djuth F; Shung KK
    IEEE Trans Ultrason Ferroelectr Freq Control; 2009 Oct; 56(10):2304-10. PubMed ID: 19942516
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Micro-machined high-frequency (80 MHz) PZT thick film linear arrays.
    Zhou Q; Wu D; Liu C; Zhu B; Djuth F; Shung K
    IEEE Trans Ultrason Ferroelectr Freq Control; 2010 Oct; 57(10):2213-20. PubMed ID: 20889407
    [TBL] [Abstract][Full Text] [Related]  

  • 3. High-frequency (>50 MHz) medical ultrasound linear arrays fabricated from micromachined bulk PZT materials.
    Liu C; Zhou Q; Djuth FT; Shung KK
    IEEE Trans Ultrason Ferroelectr Freq Control; 2012 Feb; 59(2):315-8. PubMed ID: 24626041
    [TBL] [Abstract][Full Text] [Related]  

  • 4. PMN-PT single-crystal high-frequency kerfless phased array.
    Chen R; Cabrera-Munoz NE; Lam KH; Hsu HS; Zheng F; Zhou Q; Shung KK
    IEEE Trans Ultrason Ferroelectr Freq Control; 2014 Jun; 61(6):1033-41. PubMed ID: 24859667
    [TBL] [Abstract][Full Text] [Related]  

  • 5. 25 MHz ultrasonic transducers with lead-free piezoceramic, 1-3 PZT fiber-epoxy composite, and PVDF polymer active elements.
    Jadidian B; Hagh NM; Winder AA; Safari A
    IEEE Trans Ultrason Ferroelectr Freq Control; 2009 Feb; 56(2):368-78. PubMed ID: 19251524
    [TBL] [Abstract][Full Text] [Related]  

  • 6. New fabrication of high-frequency (100-MHz) ultrasound PZT film kerfless linear array.
    Zhu B; Chan NY; Dai J; Shung KK; Takeuchi S; Zhou Q
    IEEE Trans Ultrason Ferroelectr Freq Control; 2013 Apr; 60(4):854-7. PubMed ID: 23549547
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Fabrication and characterization of piezoelectric micromachined ultrasonic transducers with thick composite PZT films.
    Wang Z; Zhu W; Zhu H; Miao J; Chao C; Zhao C; Tan OK
    IEEE Trans Ultrason Ferroelectr Freq Control; 2005 Dec; 52(12):2289-97. PubMed ID: 16463494
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A spherically-shaped PZT thin film ultrasonic transducer with an acoustic impedance gradient matching layer based on a micromachined periodically structured flexible substrate.
    Feng GH; Liu WF
    Sensors (Basel); 2013 Oct; 13(10):13543-59. PubMed ID: 24113683
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Ultrasonic array of thick film transducers for biological tissue characterization.
    Gwirc SN; Negreira CA; Marino NR
    Annu Int Conf IEEE Eng Med Biol Soc; 2010; 2010():186-9. PubMed ID: 21097177
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Multi-layered PZT/polymer composites to increase signal-to-noise ratio and resolution for medical ultrasound transducers part II: thick film technology.
    Mills DM; Smith SW
    IEEE Trans Ultrason Ferroelectr Freq Control; 2002 Jul; 49(7):1005-14. PubMed ID: 12152936
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Lead zirconate titanate-based thick films for high-frequency focused ultrasound transducers prepared by electrophoretic deposition.
    Abellard AP; Kuscer D; Grégoire JM; Lethiecq M; Malic B; Levassort F
    IEEE Trans Ultrason Ferroelectr Freq Control; 2014 Mar; 61(3):547-56. PubMed ID: 24569258
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A high-frequency annular-array transducer using an interdigital bonded 1-3 composite.
    Chabok HR; Cannata JM; Kim HH; Williams JA; Park J; Shung KK
    IEEE Trans Ultrason Ferroelectr Freq Control; 2011 Jan; 58(1):206-14. PubMed ID: 21244988
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Screen-printed ultrasonic 2-D matrix array transducers for microparticle manipulation.
    Qiu Y; Wang H; Gebhardt S; Bolhovitins A; Démoré CE; Schönecker A; Cochran S
    Ultrasonics; 2015 Sep; 62():136-46. PubMed ID: 26026870
    [TBL] [Abstract][Full Text] [Related]  

  • 14. High frequency broadband PZT thick film ultrasonic transducers for medical imaging applications.
    Zhang QQ; Djuth FT; Zhou QF; Hu CH; Cha JH; Shung KK
    Ultrasonics; 2006 Dec; 44 Suppl 1():e711-5. PubMed ID: 16793087
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Characterization of Kerfless Linear Arrays Based on PZT Thick Film.
    Zawada T; Bierregaard LM; Ringgaard E; Xu R; Guizzetti M; Levassort F; Certon D
    IEEE Trans Ultrason Ferroelectr Freq Control; 2017 Sep; 64(9):1409-1416. PubMed ID: 28574350
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Samarium and manganese-doped lead titanate ceramic fiber/epoxy 1-3 composite for high-frequency transducer application.
    Li K; Chan HL; Choy CL
    IEEE Trans Ultrason Ferroelectr Freq Control; 2003 Oct; 50(10):1371-6. PubMed ID: 14609077
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Fabrication and characterization of annular thickness mode piezoelectric micro ultrasonic transducers.
    Dorey RA; Dauchy F; Wang D; Berriet R
    IEEE Trans Ultrason Ferroelectr Freq Control; 2007 Dec; 54(12):2462-8. PubMed ID: 18276538
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A highly sensitive Pb(Zr,Ti)O3 thin film ultrasonic micro-sensor with a grooved diaphragm.
    Matsushima T; Xiong S; Kawada H; Yamanaka H; Muralt P
    IEEE Trans Ultrason Ferroelectr Freq Control; 2007 Dec; 54(12):2439-45. PubMed ID: 18276535
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Imaging arrays with improved transmit power capability.
    Zipparo MJ; Bing KF; Nightingale KR
    IEEE Trans Ultrason Ferroelectr Freq Control; 2010 Sep; 57(9):2076-90. PubMed ID: 20875996
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Lead zirconate titanate aerogel piezoelectric composite designed with a biomimetic shell structure for underwater acoustic transducers.
    Long X; Wei X; Qiu Y; Jiang M; Chen Z; Song Y; Bi L; Wang J; Wang S; Liao J
    Chem Commun (Camb); 2021 Sep; 57(76):9764-9767. PubMed ID: 34486001
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.