These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

145 related articles for article (PubMed ID: 19947731)

  • 1. Improvement of windowed type environmental-cell transmission electron microscope for in situ observation of gas-solid interactions.
    Kawasaki T; Ueda K; Ichihashi M; Tanji T
    Rev Sci Instrum; 2009 Nov; 80(11):113701. PubMed ID: 19947731
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Design and Applications of Environmental Cell Transmission Electron Microscope for In Situ Observations of Gas-Solid Reactions.
    Sharma R
    Microsc Microanal; 2001 Nov; 7(6):494-506. PubMed ID: 12597794
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Development of a gas injection/specimen heating holder for use with transmission electron microscope.
    Kamino T; Yaguchi T; Konno M; Watabe A; Marukawa T; Mima T; Kuroda K; Saka H; Arai S; Makino H; Suzuki Y; Kishita K
    J Electron Microsc (Tokyo); 2005 Dec; 54(6):497-503. PubMed ID: 16495345
    [TBL] [Abstract][Full Text] [Related]  

  • 4. In situ TEM study of catalytic nanoparticle reactions in atmospheric pressure gas environment.
    Xin HL; Niu K; Alsem DH; Zheng H
    Microsc Microanal; 2013 Dec; 19(6):1558-68. PubMed ID: 24011167
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The formation of carbon nanostructures by in situ TEM mechanical nanoscale fatigue and fracture of carbon thin films.
    Wang JJ; Lockwood AJ; Peng Y; Xu X; Bobji MS; Inkson BJ
    Nanotechnology; 2009 Jul; 20(30):305703. PubMed ID: 19584415
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Development of an analytical environmental TEM system and its application.
    Kishita K; Sakai H; Tanaka H; Saka H; Kuroda K; Sakamoto M; Watabe A; Kamino T
    J Electron Microsc (Tokyo); 2009 Dec; 58(6):331-9. PubMed ID: 19520735
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Kinetic measurements from in situ TEM observations.
    Sharma R
    Microsc Res Tech; 2009 Mar; 72(3):144-52. PubMed ID: 19130611
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Developing of an environmental cell TEM holder for dynamic in situ observation.
    Bataineh KM
    Rev Sci Instrum; 2016 Feb; 87(2):023705. PubMed ID: 26931858
    [TBL] [Abstract][Full Text] [Related]  

  • 9. An in situ nanoindentation specimen holder for a high voltage transmission electron microscope.
    Wall MA; Dahmen U
    Microsc Res Tech; 1998 Aug; 42(4):248-54. PubMed ID: 9779829
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A combined environmental straining specimen holder for high-voltage electron microscopy.
    Takahashi Y; Tanaka M; Higashida K; Yasuda K; Matsumura S; Noguchi H
    Ultramicroscopy; 2010 Oct; 110(11):1420-7. PubMed ID: 20696527
    [TBL] [Abstract][Full Text] [Related]  

  • 11. In situ high temperature TEM observation of interaction between multi-walled carbon nanotube and in situ deposited gold nano-particles.
    Kamino T; Yaguchi T; Konno M; Hashimoto T
    J Electron Microsc (Tokyo); 2005 Oct; 54(5):461-5. PubMed ID: 16195362
    [TBL] [Abstract][Full Text] [Related]  

  • 12. In situ HVEM study on copper oxidation using an improved environmental cell.
    Komatsu M; Mori H
    J Electron Microsc (Tokyo); 2005 Apr; 54(2):99-107. PubMed ID: 15994204
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A (S)TEM gas cell holder with localized laser heating for in situ experiments.
    Mehraeen S; McKeown JT; Deshmukh PV; Evans JE; Abellan P; Xu P; Reed BW; Taheri ML; Fischione PE; Browning ND
    Microsc Microanal; 2013 Apr; 19(2):470-8. PubMed ID: 23452391
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Method for Cross-sectional Thin Specimen Preparation from a Specific Site Using a Combination of a Focused Ion Beam System and Intermediate Voltage Electron Microscope and Its Application to the Characterization of a Precipitate in a Steel.
    Yaguchi T; Matsumoto H; Kamino T; Ishitani T; Urao R
    Microsc Microanal; 2001 May; 7(3):287-291. PubMed ID: 12597819
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Nanosecond time-resolved investigations using the in situ of dynamic transmission electron microscope (DTEM).
    LaGrange T; Campbell GH; Reed BW; Taheri M; Pesavento JB; Kim JS; Browning ND
    Ultramicroscopy; 2008 Oct; 108(11):1441-9. PubMed ID: 18783886
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Development of a high temperature-atmospheric pressure environmental cell for high-resolution TEM.
    Yaguchi T; Suzuki M; Watabe A; Nagakubo Y; Ueda K; Kamino T
    J Electron Microsc (Tokyo); 2011; 60(3):217-25. PubMed ID: 21427119
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A carbon sandwich environmental cell for wet specimens.
    Inayoshi Y; Minoda H
    Microscopy (Oxf); 2013 Dec; 62(6):623-8. PubMed ID: 23620337
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Ex situ transmission electron microscopy: a fixed-bed reactor approach.
    Kliewer CE; Kiss G; Demartin GJ
    Microsc Microanal; 2006 Apr; 12(2):135-44. PubMed ID: 17481349
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Localised corrosion in aluminium alloy 2024-T3 using in situ TEM.
    Malladi S; Shen C; Xu Q; de Kruijff T; YĆ¼celen E; Tichelaar F; Zandbergen H
    Chem Commun (Camb); 2013 Nov; 49(92):10859-61. PubMed ID: 24127075
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Development of a technique for high resolution electron microscopic observation of nano-materials at elevated temperatures.
    Kamino T; Yaguchi T; Sato T; Hashimoto T
    J Electron Microsc (Tokyo); 2005 Dec; 54(6):505-8. PubMed ID: 16495344
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.