147 related articles for article (PubMed ID: 19949117)
1. Mid-term results of the modular ANCA-Fit femoral component in total hip replacement.
Blakey CM; Eswaramoorthy VK; Hamilton LC; Biant LC; Field RE
J Bone Joint Surg Br; 2009 Dec; 91(12):1561-5. PubMed ID: 19949117
[TBL] [Abstract][Full Text] [Related]
2. The S-ROM hydroxyapatite proximally-coated modular femoral stem in revision hip replacement: results of 397 hips at a minimum ten-year follow-up.
Imbuldeniya AM; Walter WK; Zicat BA; Walter WL
Bone Joint J; 2014 Jun; 96-B(6):730-6. PubMed ID: 24891571
[TBL] [Abstract][Full Text] [Related]
3. The Freeman femoral component with hydroxyapatite coating and retention of the neck: an update with a minimum follow-up of 17 years.
Mannan K; Freeman MA; Scott G
J Bone Joint Surg Br; 2010 Apr; 92(4):480-5. PubMed ID: 20357321
[TBL] [Abstract][Full Text] [Related]
4. Modified metaphyseal-loading anterolaterally flared anatomic femoral stem: five- to nine-year prospective follow-up evaluation and results of three-dimensional finite element analysis.
Kokubo Y; Uchida K; Oki H; Negoro K; Nagamune K; Kawaguchi S; Takeno K; Yayama T; Nakajima H; Sugita D; Yoshida A; Baba H
Artif Organs; 2013 Feb; 37(2):175-82. PubMed ID: 23009086
[TBL] [Abstract][Full Text] [Related]
5. Hydroxyapatite-ceramic-coated femoral stems in revision hip surgery.
Trikha SP; Singh S; Raynham OW; Lewis JC; Mitchell PA; Edge AJ
J Bone Joint Surg Br; 2005 Aug; 87(8):1055-60. PubMed ID: 16049238
[TBL] [Abstract][Full Text] [Related]
6. Revision of cemented hip arthroplasty using a hydroxyapatite-ceramic-coated femoral component.
Raman R; Kamath RP; Parikh A; Angus PD
J Bone Joint Surg Br; 2005 Aug; 87(8):1061-7. PubMed ID: 16049239
[TBL] [Abstract][Full Text] [Related]
7. Clinical results, radiological findings and survival of a proximally hydroxyapatite-coated hip ABG II stem at a minimum of ten years' follow-up: results of a consecutive multicentre study of 1148 hips in 1053 patients.
Epinette JA; Asencio G; Essig J; Llagonne B; Nourissat C
Bone Joint J; 2013 Dec; 95-B(12):1610-6. PubMed ID: 24293589
[TBL] [Abstract][Full Text] [Related]
8. Hydroxyapatite-ceramic-coated femoral components in young patients followed-up for 16 to 19 years: an update of a previous report.
Shah NN; Edge AJ; Clark DW
J Bone Joint Surg Br; 2009 Jul; 91(7):865-9. PubMed ID: 19567848
[TBL] [Abstract][Full Text] [Related]
9. Long-term results of a hydroxyapatite-coated femoral component in total hip replacement: a 15- to 21-year follow-up study.
Rajaratnam SS; Jack C; Tavakkolizadeh A; George MD; Fletcher RJ; Hankins M; Shepperd JA
J Bone Joint Surg Br; 2008 Jan; 90(1):27-30. PubMed ID: 18160495
[TBL] [Abstract][Full Text] [Related]
10. Uncemented custom computer-assisted design and manufacture of hydroxyapatite-coated femoral components: survival at 10 to 17 years.
Muirhead-Allwood SK; Sandiford N; Skinner JA; Hua J; Kabir C; Walker PS
J Bone Joint Surg Br; 2010 Aug; 92(8):1079-84. PubMed ID: 20675750
[TBL] [Abstract][Full Text] [Related]
11. Long-term results of the ABG-1 hydroxyapatite coated total hip arthroplasty: analysis of 111 cases with a minimum follow-up of 10 years.
Bidar R; Kouyoumdjian P; Munini E; Asencio G
Orthop Traumatol Surg Res; 2009 Dec; 95(8):579-87. PubMed ID: 19926546
[TBL] [Abstract][Full Text] [Related]
12. High rate of fracture in the cementless modular Extrême™ (Mark I) femoral prosthesis in revision total hip arthroplasty: 33 cases at more than 5 years' follow-up.
Benoist J; Lambotte JC; Polard JL; Huten D
Orthop Traumatol Surg Res; 2013 Dec; 99(8):915-21. PubMed ID: 24211127
[TBL] [Abstract][Full Text] [Related]
13. [Long-term results of the CLS acetabular cup in primary total hip replacement].
Rozkydal Z; Janícek P; Tomás T; Florian Z
Acta Chir Orthop Traumatol Cech; 2009 Apr; 76(2):90-7. PubMed ID: 19439127
[TBL] [Abstract][Full Text] [Related]
14. Femoral deficiency reconstruction using a hydroxyapatite-coated locked modular stem. A series of 43 total hip revisions.
Philippot R; Delangle F; Verdot FX; Farizon F; Fessy MH
Orthop Traumatol Surg Res; 2009 Apr; 95(2):119-26. PubMed ID: 19297264
[TBL] [Abstract][Full Text] [Related]
15. Total hip arthroplasty with an uncemented tapered femoral component.
McLaughlin JR; Lee KR
J Bone Joint Surg Am; 2008 Jun; 90(6):1290-6. PubMed ID: 18519323
[TBL] [Abstract][Full Text] [Related]
16. Proximal femoral bone loss and increased rate of fracture with a proximally hydroxyapatite-coated femoral component.
Radl R; Aigner C; Hungerford M; Pascher A; Windhager R
J Bone Joint Surg Br; 2000 Nov; 82(8):1151-5. PubMed ID: 11132277
[TBL] [Abstract][Full Text] [Related]
17. Long term results of the Corin C-Fit uncemented total hip arthroplasty in young patients.
Raj D; Jaiswal PK; Sharma BL; Fergusson CM
Arch Orthop Trauma Surg; 2008 Dec; 128(12):1391-5. PubMed ID: 18176810
[TBL] [Abstract][Full Text] [Related]
18. The results of a proximally-coated cementless femoral component in total hip replacement: a five- to 12-year follow-up.
Kim YH
J Bone Joint Surg Br; 2008 Mar; 90(3):299-305. PubMed ID: 18310749
[TBL] [Abstract][Full Text] [Related]
19. Results of a hydroxyapatite-coated modular femoral stem in primary total hip arthroplasty. A minimum 5-year follow-up.
Garcia-Rey E; Muñoz T; Montejo J; Martinez J
J Arthroplasty; 2008 Dec; 23(8):1132-9. PubMed ID: 18534471
[TBL] [Abstract][Full Text] [Related]
20. [Long-term experience with the combined ARBOND hydroxyapatite coating in implant osteointegration].
Landor I; Vavrík P; Jahoda D; Pokorný D; Ballay R; Sosna A
Acta Chir Orthop Traumatol Cech; 2009 Jun; 76(3):172-8. PubMed ID: 19595277
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]