161 related articles for article (PubMed ID: 19956966)
1. Release of metals from osteosynthesis implants as a method for identification: post-autopsy histopathological and ultrastructural forensic study.
Palazzo E; Andreola S; Battistini A; Gentile G; Zoja R
Int J Legal Med; 2011 Jan; 125(1):21-6. PubMed ID: 19956966
[TBL] [Abstract][Full Text] [Related]
2. Difference in metallic wear distribution released from commercially pure titanium compared with stainless steel plates.
Krischak GD; Gebhard F; Mohr W; Krivan V; Ignatius A; Beck A; Wachter NJ; Reuter P; Arand M; Kinzl L; Claes LE
Arch Orthop Trauma Surg; 2004 Mar; 124(2):104-13. PubMed ID: 14727127
[TBL] [Abstract][Full Text] [Related]
3. Osseointegration of metallic implants. II. Transmission electron microscopy in the rabbit.
Linder L; Obrant K; Boivin G
Acta Orthop Scand; 1989 Apr; 60(2):135-9. PubMed ID: 2658465
[TBL] [Abstract][Full Text] [Related]
4. Interface between titanium 6,4 alloy implants and bone.
Katsikeris N; Listrom RD; Symington JM
Int J Oral Maxillofac Surg; 1987 Aug; 16(4):473-6. PubMed ID: 3117922
[TBL] [Abstract][Full Text] [Related]
5. [Tissue metallosis of the implant bed as a late complication of metal osteosynthesis].
Zaitseva KK; Gritsanov AI
Arkh Patol; 1984; 46(8):37-45. PubMed ID: 6497696
[TBL] [Abstract][Full Text] [Related]
6. In vivo metal-ion release from porous titanium-fiber material.
Ducheyne P; Willems G; Martens M; Helsen J
J Biomed Mater Res; 1984 Mar; 18(3):293-308. PubMed ID: 6715394
[TBL] [Abstract][Full Text] [Related]
7. Bone response to a titanium aluminium nitride coating on metallic implants.
Freeman CO; Brook IM
J Mater Sci Mater Med; 2006 May; 17(5):465-70. PubMed ID: 16688587
[TBL] [Abstract][Full Text] [Related]
8. Ultrastructural analysis of metallic debris and tissue reaction around spinal implants in patients with late operative site pain.
Senaran H; Atilla P; Kaymaz F; Acaroglu E; Surat A
Spine (Phila Pa 1976); 2004 Aug; 29(15):1618-23; discussion 1623. PubMed ID: 15284504
[TBL] [Abstract][Full Text] [Related]
9. An ultrastructural characterization of the interface between bone and sputtered titanium or stainless steel surfaces.
Albrektsson T; Hansson HA
Biomaterials; 1986 May; 7(3):201-5. PubMed ID: 3521751
[TBL] [Abstract][Full Text] [Related]
10. A Brief Review of Scanning Electron Microscopy With Energy-Dispersive X-ray Use in Forensic Medicine.
Gentile G; Andreola S; Bailo P; Battistini A; Boracchi M; Tambuzzi S; Zoja R
Am J Forensic Med Pathol; 2020 Dec; 41(4):280-286. PubMed ID: 32852293
[TBL] [Abstract][Full Text] [Related]
11. [Ultrasound imaging and localization of metal implants. A clinical study].
Grechenig W; Clement HG; Fellinger M; Schleifer P; Tesch PN
Unfallchirurgie; 1996 Jun; 22(3):117-23. PubMed ID: 8767382
[TBL] [Abstract][Full Text] [Related]
12. Detection of metal residues on bone using SEM-EDS. Part I: Blunt force injury.
Pechníková M; Porta D; Mazzarelli D; Rizzi A; Drozdová E; Gibelli D; Cattaneo C
Forensic Sci Int; 2012 Nov; 223(1-3):87-90. PubMed ID: 22989600
[TBL] [Abstract][Full Text] [Related]
13. Bioinspired surface functionalization of metallic biomaterials.
Su Y; Luo C; Zhang Z; Hermawan H; Zhu D; Huang J; Liang Y; Li G; Ren L
J Mech Behav Biomed Mater; 2018 Jan; 77():90-105. PubMed ID: 28898726
[TBL] [Abstract][Full Text] [Related]
14. In vitro corrosion study of porous metal fibre coatings for bone ingrowth.
Ducheyne P
Biomaterials; 1983 Jul; 4(3):185-91. PubMed ID: 6615981
[TBL] [Abstract][Full Text] [Related]
15. Is galvanic corrosion between titanium alloy and stainless steel spinal implants a clinical concern?
Serhan H; Slivka M; Albert T; Kwak SD
Spine J; 2004; 4(4):379-87. PubMed ID: 15246296
[TBL] [Abstract][Full Text] [Related]
16. Ultrastructural differences of the interface zone between bone and Ti 6Al 4V or commercially pure titanium.
Johansson C; Lausmaa J; Ask M; Hansson HA; Albrektsson T
J Biomed Eng; 1989 Jan; 11(1):3-8. PubMed ID: 2927096
[TBL] [Abstract][Full Text] [Related]
17. [Prospective study of the significance of contact sensitization caused by metal implants].
Duchna HW; Nowack U; Merget R; Muhr G; Schultze-Werninghaus G
Zentralbl Chir; 1998; 123(11):1271-6. PubMed ID: 9880846
[TBL] [Abstract][Full Text] [Related]
18. Evaluation of MR issues for the latest standard brands of orthopedic metal implants: plates and screws.
Zou YF; Chu B; Wang CB; Hu ZY
Eur J Radiol; 2015 Mar; 84(3):450-457. PubMed ID: 25544555
[TBL] [Abstract][Full Text] [Related]
19. [Osteosynthesis with metal prosthesis].
SARPYENER MA
Turk Tip Cemiy Mecm; 1956 Feb; 22(2):131-6. PubMed ID: 13352433
[No Abstract] [Full Text] [Related]
20. Osseointegrated titanium implants. Requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man.
Albrektsson T; Brånemark PI; Hansson HA; Lindström J
Acta Orthop Scand; 1981; 52(2):155-70. PubMed ID: 7246093
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]