These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
200 related articles for article (PubMed ID: 19960469)
1. A systematic study in CIEF: defining and optimizing experimental parameters critical to method reproducibility and robustness. Mack S; Cruzado-Park I; Chapman J; Ratnayake C; Vigh G Electrophoresis; 2009 Dec; 30(23):4049-58. PubMed ID: 19960469 [TBL] [Abstract][Full Text] [Related]
2. Element of a validation method for MU-B3 monoclonal antibody using an imaging capillary isoelectric focusing system. Janini G; Saptharishi N; Waselus M; Soman G Electrophoresis; 2002 Jun; 23(11):1605-11. PubMed ID: 12179978 [TBL] [Abstract][Full Text] [Related]
3. Effect of electrolyte pH on CIEF with narrow pH range ampholytes. Páger C; Vargová A; Takácsi-Nagy A; Dörnyei Á; Kilár F Electrophoresis; 2012 Nov; 33(22):3269-75. PubMed ID: 23086725 [TBL] [Abstract][Full Text] [Related]
4. Comparison of different capillary isoelectric focusing methods--use of "narrow pH cuts" of carrier ampholytes as original tools to improve resolution. Poitevin M; Morin A; Busnel JM; Descroix S; Hennion MC; Peltre G J Chromatogr A; 2007 Jul; 1155(2):230-6. PubMed ID: 17335834 [TBL] [Abstract][Full Text] [Related]
5. Profiling recombinant major birch pollen allergen Bet v 1a and carbamylated variants with CZE and CIEF. Kronsteiner B; Malissa H; Stutz H Electrophoresis; 2007 Jul; 28(13):2241-51. PubMed ID: 17538926 [TBL] [Abstract][Full Text] [Related]
6. Carrier ampholytes for IEF, on their fortieth anniversary (1967-2007), brought to trial in court: the verdict. Righetti PG; Simó C; Sebastiano R; Citterio A Electrophoresis; 2007 Nov; 28(21):3799-810. PubMed ID: 17922506 [TBL] [Abstract][Full Text] [Related]
7. Transient isotachophoresis in carrier ampholyte-based capillary electrophoresis for protein analysis. Busnel JM; Descroix S; Godfrin D; Hennion MC; Kasicka V; Peltre G Electrophoresis; 2006 Sep; 27(18):3591-8. PubMed ID: 16977683 [TBL] [Abstract][Full Text] [Related]
8. Isoelectric focusing of monoclonal antibodies by capillary electrophoresis. Kundu S; Fenters C J Capillary Electrophor; 1995; 2(6):273-7. PubMed ID: 9384786 [TBL] [Abstract][Full Text] [Related]
10. Optimization of an IgG1 CIEF separation by using narrow-range ampholytes and DMSO as protein solubilizer. Cruzado-Park ID Electrophoresis; 2020 Aug; 41(15):1308-1315. PubMed ID: 32375204 [TBL] [Abstract][Full Text] [Related]
11. Isoelectric buffers, part 3: determination of pKa and pI values of diamino sulfate carrier ampholytes by indirect UV-detection capillary electrophoresis. Lalwani S; Tutu E; Vigh G Electrophoresis; 2005 Jun; 26(13):2503-10. PubMed ID: 15937983 [TBL] [Abstract][Full Text] [Related]
12. High-resolution dynamic computer simulation analysis of the behavior of sample components with pI values outside the pH gradient established by carrier ampholyte CIEF. Thormann W; Kilár F Electrophoresis; 2013 Mar; 34(5):716-24. PubMed ID: 23229109 [TBL] [Abstract][Full Text] [Related]
13. Peak identification in capillary isoelectric focusing using the concept of relative peak position as determined by two isoelectric point markers. Wu J; Huang T Electrophoresis; 2006 Sep; 27(18):3584-90. PubMed ID: 16927345 [TBL] [Abstract][Full Text] [Related]
14. Analysis of four therapeutic monoclonal antibodies by online capillary isoelectric focusing directly coupled to quadrupole time-of-flight mass spectrometry. Wang L; Chen DDY Electrophoresis; 2019 Nov; 40(21):2899-2907. PubMed ID: 31407816 [TBL] [Abstract][Full Text] [Related]
15. Affinity mode of capillary isoelectric focusing for the characterization of the biotin-binding protein actinavidin. Okun VM Electrophoresis; 1998 Mar; 19(3):427-32. PubMed ID: 9551796 [TBL] [Abstract][Full Text] [Related]
16. Determination of the operational pH value of a buffering membrane by an isoelectric trapping separation of a carrier ampholyte mixture. North RY; Vigh G Electrophoresis; 2008 Mar; 29(5):1077-81. PubMed ID: 18271066 [TBL] [Abstract][Full Text] [Related]
17. Carrier ampholytes rehabilitated: gel isoelectric focusing on pH gradients visualized in real-time by automated fluorescence scanning in the HPGE-1000 apparatus. Gombocz E; Cortez E Electrophoresis; 1999 Jun; 20(7):1365-72. PubMed ID: 10424457 [TBL] [Abstract][Full Text] [Related]
18. Modeling of formation and prevention of a pure water zone in capillary isoelectric focusing with narrow pH range carrier ampholytes. Takácsi-Nagy A; Kilár F; Thormann W Electrophoresis; 2017 Mar; 38(5):677-688. PubMed ID: 27699824 [TBL] [Abstract][Full Text] [Related]
19. CIEF with hydrodynamic and chemical mobilization for the separation of forms of alpha-1-acid glycoprotein. Lacunza I; Diez-Masa JC; de Frutos M Electrophoresis; 2007 Apr; 28(8):1204-13. PubMed ID: 17366481 [TBL] [Abstract][Full Text] [Related]
20. Protein characterization by on-line capillary isoelectric focusing, reversed-phase liquid chromatography, and mass spectrometry. Zhou F; Johnston MV Anal Chem; 2004 May; 76(10):2734-40. PubMed ID: 15144182 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]