187 related articles for article (PubMed ID: 19963721)
1. Electrode design for high frequency block: effect of bipolar separation on block thresholds and the onset response.
Ackermann D; Foldes EL; Bhadra N; Kilgore KL
Annu Int Conf IEEE Eng Med Biol Soc; 2009; 2009():654-7. PubMed ID: 19963721
[TBL] [Abstract][Full Text] [Related]
2. Effect of bipolar cuff electrode design on block thresholds in high-frequency electrical neural conduction block.
Ackermann DM; Foldes EL; Bhadra N; Kilgore KL
IEEE Trans Neural Syst Rehabil Eng; 2009 Oct; 17(5):469-77. PubMed ID: 19840914
[TBL] [Abstract][Full Text] [Related]
3. Reduction of the onset response in high frequency nerve block with amplitude ramps from non-zero amplitudes.
Bhadra N; Foldes EL; Ackermann D; Kilgore KL
Annu Int Conf IEEE Eng Med Biol Soc; 2009; 2009():650-3. PubMed ID: 19963720
[TBL] [Abstract][Full Text] [Related]
4. Effect of nerve cuff electrode geometry on onset response firing in high-frequency nerve conduction block.
Ackermann DM; Bhadra N; Foldes EL; Wang XF; Kilgore KL
IEEE Trans Neural Syst Rehabil Eng; 2010 Dec; 18(6):658-65. PubMed ID: 20813650
[TBL] [Abstract][Full Text] [Related]
5. Continuous Direct Current Nerve Block Using Multi Contact High Capacitance Electrodes.
Vrabec T; Bhadra N; Van Acker G; Bhadra N; Kilgore K
IEEE Trans Neural Syst Rehabil Eng; 2017 Jun; 25(6):517-529. PubMed ID: 27411224
[TBL] [Abstract][Full Text] [Related]
6. Muscle-selective block using intrafascicular high-frequency alternating current.
Dowden BR; Wark HA; Normann RA
Muscle Nerve; 2010 Sep; 42(3):339-47. PubMed ID: 20806397
[TBL] [Abstract][Full Text] [Related]
7. Conduction block of peripheral nerve using high-frequency alternating currents delivered through an intrafascicular electrode.
Ackermann DM; Foldes EL; Bhadra N; Kilgore KL
Muscle Nerve; 2010 Jan; 41(1):117-9. PubMed ID: 19813186
[TBL] [Abstract][Full Text] [Related]
8. Conduction block of whole nerve without onset firing using combined high frequency and direct current.
Ackermann DM; Bhadra N; Foldes EL; Kilgore KL
Med Biol Eng Comput; 2011 Feb; 49(2):241-51. PubMed ID: 20890673
[TBL] [Abstract][Full Text] [Related]
9. High-frequency electrical conduction block of mammalian peripheral motor nerve.
Bhadra N; Kilgore KL
Muscle Nerve; 2005 Dec; 32(6):782-90. PubMed ID: 16124008
[TBL] [Abstract][Full Text] [Related]
10. High frequency mammalian nerve conduction block: simulations and experiments.
Kilgore KL; Bhadra N
Conf Proc IEEE Eng Med Biol Soc; 2006; 2006():4971-4. PubMed ID: 17946274
[TBL] [Abstract][Full Text] [Related]
11. Differential fiber-specific block of nerve conduction in mammalian peripheral nerves using kilohertz electrical stimulation.
Patel YA; Butera RJ
J Neurophysiol; 2015 Jun; 113(10):3923-9. PubMed ID: 25878155
[TBL] [Abstract][Full Text] [Related]
12. Counted cycles method to quantify the onset response in high-frequency peripheral nerve block.
Foldes EL; Ackermann D; Bhadra N; Kilgore KL
Annu Int Conf IEEE Eng Med Biol Soc; 2009; 2009():614-7. PubMed ID: 19963719
[TBL] [Abstract][Full Text] [Related]
13. Effects of ramped amplitude waveforms on the onset response of high-frequency mammalian nerve block.
Miles JD; Kilgore KL; Bhadra N; Lahowetz EA
J Neural Eng; 2007 Dec; 4(4):390-8. PubMed ID: 18057506
[TBL] [Abstract][Full Text] [Related]
14. Fascicle-selectivity of an intraneural stimulation electrode in the rabbit sciatic nerve.
Nielsen TN; Sevcencu C; Struijk JJ
IEEE Trans Biomed Eng; 2012 Jan; 59(1):192-7. PubMed ID: 21954195
[TBL] [Abstract][Full Text] [Related]
15. Combined direct current and high frequency nerve block for elimination of the onset response.
Kilgore KL; Foldes EA; Ackermann DM; Bhadra N
Annu Int Conf IEEE Eng Med Biol Soc; 2009; 2009():197-9. PubMed ID: 19964208
[TBL] [Abstract][Full Text] [Related]
16. Nerve conduction block using combined thermoelectric cooling and high frequency electrical stimulation.
Ackermann DM; Foldes EL; Bhadra N; Kilgore KL
J Neurosci Methods; 2010 Oct; 193(1):72-6. PubMed ID: 20705099
[TBL] [Abstract][Full Text] [Related]
17. Simulation of high-frequency sinusoidal electrical block of mammalian myelinated axons.
Bhadra N; Lahowetz EA; Foldes ST; Kilgore KL
J Comput Neurosci; 2007 Jun; 22(3):313-26. PubMed ID: 17200886
[TBL] [Abstract][Full Text] [Related]
18. Frequency- and amplitude-transitioned waveforms mitigate the onset response in high-frequency nerve block.
Gerges M; Foldes EL; Ackermann DM; Bhadra N; Bhadra N; Kilgore KL
J Neural Eng; 2010 Dec; 7(6):066003. PubMed ID: 20966536
[TBL] [Abstract][Full Text] [Related]
19. Kilohertz Electrical Stimulation Nerve Conduction Block: Effects of Electrode Surface Area.
Patel YA; Kim BS; Rountree WS; Butera RJ
IEEE Trans Neural Syst Rehabil Eng; 2017 Oct; 25(10):1906-1916. PubMed ID: 28328507
[TBL] [Abstract][Full Text] [Related]
20. Optimizing the design of bipolar nerve cuff electrodes for improved recording of peripheral nerve activity.
Sabetian P; Popovic MR; Yoo PB
J Neural Eng; 2017 Jun; 14(3):036015. PubMed ID: 28251960
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]