These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

200 related articles for article (PubMed ID: 19964042)

  • 1. A heterogeneous breast phantom for microwave breast imaging.
    Ostadrahimi M; Reopelle R; Noghanian S; Pistorius S; Vahedi A; Safari F
    Annu Int Conf IEEE Eng Med Biol Soc; 2009; 2009():2727-30. PubMed ID: 19964042
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Development of non-uniform breast phantom and its microwave imaging for tumor detection by CP-MCT.
    Miyakawa M; Takata S; Inotsume K
    Annu Int Conf IEEE Eng Med Biol Soc; 2009; 2009():2723-6. PubMed ID: 19964041
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Three-dimensional quantitative microwave imaging of realistic numerical breast phantoms using Huber regularization.
    Bai F; Franchois A; De Zaeytijd J; Pižurica A
    Annu Int Conf IEEE Eng Med Biol Soc; 2013; 2013():5135-8. PubMed ID: 24110891
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Three-dimensional microwave imaging of realistic numerical breast phantoms via a multiple-frequency inverse scattering technique.
    Shea JD; Kosmas P; Hagness SC; Van Veen BD
    Med Phys; 2010 Aug; 37(8):4210-26. PubMed ID: 20879582
    [TBL] [Abstract][Full Text] [Related]  

  • 5. 3D breast microwave imaging based on wavefront reconstruction.
    Flores-Tapia D; Thomas G; Ashtari A; Pistorius S
    Conf Proc IEEE Eng Med Biol Soc; 2006; 2006():2542-5. PubMed ID: 17946520
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Dielectric characterization of PCL-based thermoplastic materials for microwave diagnostic and therapeutic applications.
    Aguilar SM; Shea JD; Al-Joumayly MA; Van Veen BD; Behdad N; Hagness SC
    IEEE Trans Biomed Eng; 2012 Mar; 59(3):627-33. PubMed ID: 21622068
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Multimodal Breast Phantoms for Microwave, Ultrasound, Mammography, Magnetic Resonance and Computed Tomography Imaging.
    Ruvio G; Solimene R; Cuccaro A; Fiaschetti G; Fagan AJ; Cournane S; Cooke J; Ammann MJ; Tobon J; Browne JE
    Sensors (Basel); 2020 Apr; 20(8):. PubMed ID: 32340281
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Realistic microwave breast models through T1-weighted 3-D MRI data.
    Tunçay AH; Akduman I
    IEEE Trans Biomed Eng; 2015 Feb; 62(2):688-98. PubMed ID: 25347868
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A comparison of data-independent microwave beamforming algorithms for the early detection of breast cancer.
    Byrne D; O'Halloran M; Jones E; Glavin M
    Annu Int Conf IEEE Eng Med Biol Soc; 2009; 2009():2731-4. PubMed ID: 19964043
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A comparison of interpolation methods for breast microwave radar imaging.
    Flores-Tapia D; Thomas G; Pistorius S
    Annu Int Conf IEEE Eng Med Biol Soc; 2009; 2009():2735-8. PubMed ID: 19964044
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Two-dimensional multi-frequency imaging of a tumor inclusion in a homogeneous breast phantom using the harmonic motion Doppler imaging method.
    Tafreshi AK; Top CB; Gençer NG
    Phys Med Biol; 2017 Jun; 62(12):4852-4869. PubMed ID: 28151726
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Breast tissue mimicking phantoms for combined ultrasound and microwave imaging.
    Li S; Fear E; Curiel L
    Phys Med Biol; 2021 Dec; 66(24):. PubMed ID: 34818636
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Time-domain microwave breast cancer detection: extensive system testing with phantoms.
    Porter E; Santorelli A; Coates M; Popovic M
    Technol Cancer Res Treat; 2013 Apr; 12(2):131-43. PubMed ID: 23098283
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Use of multi-angle ultra-wide band microwave sounding for high resolution breast imaging.
    Shipilov S; Eremeev A; Yakubov V; Fedyanin I; Satarov R; Zavyalova K; Shipilova S; Balzovsky E
    Med Phys; 2020 Oct; 47(10):5147-5157. PubMed ID: 32885421
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Breast cancer detection using interferometric MUSIC: experimental and numerical assessment.
    Ruvio G; Solimene R; Cuccaro A; Gaetano D; Browne JE; Ammann MJ
    Med Phys; 2014 Oct; 41(10):103101. PubMed ID: 25281985
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Tissue-mimicking phantom materials for narrowband and ultrawideband microwave applications.
    Lazebnik M; Madsen EL; Frank GR; Hagness SC
    Phys Med Biol; 2005 Sep; 50(18):4245-58. PubMed ID: 16148391
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Development of anatomically realistic numerical breast phantoms with accurate dielectric properties for modeling microwave interactions with the human breast.
    Zastrow E; Davis SK; Lazebnik M; Kelcz F; Van Veen BD; Hagness SC
    IEEE Trans Biomed Eng; 2008 Dec; 55(12):2792-800. PubMed ID: 19126460
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Data acquisition system for harmonic motion microwave Doppler imaging.
    Tafreshi AK; Karadaş M; Top CB; Gençer NG
    Annu Int Conf IEEE Eng Med Biol Soc; 2014; 2014():2873-6. PubMed ID: 25570591
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Non-invasive thermal assessment of tissue phantoms using an active near field microwave imaging technique.
    Chang JT; Paulsen K; Meaney P; Fanning M
    Int J Hyperthermia; 1998; 14(6):513-34. PubMed ID: 9886660
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Thermoacoustic imaging over large field of view for three-dimensional breast tumor localization: a phantom study.
    Fu Y; Ji Z; Ding W; Ye F; Lou C
    Med Phys; 2014 Nov; 41(11):110701. PubMed ID: 25370614
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.