These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

143 related articles for article (PubMed ID: 19964319)

  • 21. Current patterns and electrode types for single-source electrical impedance tomography of the thorax.
    Schuessler TF; Bates JH
    Ann Biomed Eng; 1998; 26(2):253-9. PubMed ID: 9525765
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Towards a theoretical understanding of stroke volume estimation with impedance cardiography.
    Faes TJ; Raaijmakers E; Meijer JH; Goovaerts HG; Heethaar RM
    Ann N Y Acad Sci; 1999 Apr; 873():128-34. PubMed ID: 10372160
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Three dimensional electrical impedance tomography in thorax complete model.
    Wu H; Xu G; Yu H; Zhang S; Li Y; Yang S; Yan W
    Annu Int Conf IEEE Eng Med Biol Soc; 2008; 2008():466-9. PubMed ID: 19162694
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Sensitivity distributions of impedance cardiography using band and spot electrodes analyzed by a three-dimensional computer model.
    Kauppinen PK; Hyttinen JA; Malmivuo JA
    Ann Biomed Eng; 1998; 26(4):694-702. PubMed ID: 9662161
    [TBL] [Abstract][Full Text] [Related]  

  • 25. A finite-element study of the effects of electrode position on the measured impedance change in impedance cardiography.
    Wang Y; Haynor DR; Kim Y
    IEEE Trans Biomed Eng; 2001 Dec; 48(12):1390-401. PubMed ID: 11759920
    [TBL] [Abstract][Full Text] [Related]  

  • 26. A simple method to check the dynamic performance of electrical impedance tomography systems.
    Hahn G; Beer M; Frerichs I; Dudykevych T; Schröder T; Hellige G
    Physiol Meas; 2000 Feb; 21(1):53-60. PubMed ID: 10719999
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Thoracic geometry and its relation to electrical current distribution: consequences for electrode placement in electrical impedance cardiography.
    Raaijmakers E; Faes TJ; Goovaerts HG; Meijer JH; de Vries PM; Heethaar RM
    Med Biol Eng Comput; 1998 Sep; 36(5):592-7. PubMed ID: 10367443
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Automatic detection of detached and erroneous electrodes in electrical impedance tomography.
    Asfaw Y; Adler A
    Physiol Meas; 2005 Apr; 26(2):S175-83. PubMed ID: 15798230
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Realistic 2D human thorax modelling for EIT.
    Borsic A; McLeod C; Lionheart W; Kerrouche N
    Physiol Meas; 2001 Feb; 22(1):77-83. PubMed ID: 11236892
    [TBL] [Abstract][Full Text] [Related]  

  • 30. [Impedance cardiography--non-invasive measurement of central hemodynamic data].
    Petersen JR; Jensen BV; Olsen F
    Ugeskr Laeger; 1992 Jan; 154(5):255-60. PubMed ID: 1736457
    [TBL] [Abstract][Full Text] [Related]  

  • 31. The contribution of the lungs to thoracic impedance measurements: a simulation study based on a high resolution finite difference model.
    Yang F; Patterson RP
    Physiol Meas; 2007 Jul; 28(7):S153-61. PubMed ID: 17664633
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Chest Movement and Respiratory Volume both Contribute to Thoracic Bioimpedance during Loaded Breathing.
    Blanco-Almazán D; Groenendaal W; Catthoor F; Jané R
    Sci Rep; 2019 Dec; 9(1):20232. PubMed ID: 31882841
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Portable bioimpedance monitor evaluation for continuous impedance measurements. Towards wearable plethysmography applications.
    Ferreira J; Seoane F; Lindecrantz K
    Annu Int Conf IEEE Eng Med Biol Soc; 2013; 2013():559-62. PubMed ID: 24109748
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Transthoracic electrical bioimpedence cardiac output: comparison with multigated equillibrium radionuclide cardiography.
    Gujjar AR; Muralidhar K; Bhandopadhyaya A; Sathyaprabha TN; Janaki P; Mahalla BK; Gupta R; Banakal S; Jairaj PS
    J Clin Monit Comput; 2010 Apr; 24(2):155-9. PubMed ID: 20229061
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Thoracic electrical bioimpedance device.
    Barney J
    Crit Care Med; 1996 Jun; 24(6):1090-1. PubMed ID: 8681580
    [No Abstract]   [Full Text] [Related]  

  • 36. Induced-current electrical impedance tomography: a 2-D theoretical simulation.
    Zlochiver S; Rosenfeld M; Abboud S
    IEEE Trans Med Imaging; 2003 Dec; 22(12):1550-60. PubMed ID: 14649745
    [TBL] [Abstract][Full Text] [Related]  

  • 37. The view within: the emerging technology of thoracic electrical bioimpedance.
    Lasater M
    Crit Care Nurs Q; 1998 Nov; 21(3):97-101. PubMed ID: 10646425
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Thoracic impedance change equation deduced on the basis of parallel impedance model and Ohm's law.
    Qiu-Jin X; Zhen W; Ming-Xing K; Ping W; Pei L; Jian-Feng J
    Med Phys; 2012 Feb; 39(2):1042-5. PubMed ID: 22320814
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Thoracic impedance measures tissue characteristics in the vicinity of the electrodes, not intervening lung water: implications for heart failure monitoring.
    Charles CJ; Rademaker MT; Melton IC; Gutfinger D; Eigler NL; Qu F; Troughton RW
    J Clin Monit Comput; 2015 Feb; 29(1):65-76. PubMed ID: 24619657
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Bioelectrical impedance techniques in medicine. Part I: Bioimpedance measurement. Second section: impedance spectrometry.
    Rigaud B; Morucci JP; Chauveau N
    Crit Rev Biomed Eng; 1996; 24(4-6):257-351. PubMed ID: 9196884
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.