These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

318 related articles for article (PubMed ID: 19969482)

  • 61. Correlation between experimental cyclic fatigue resistance and numerical stress analysis for nickel-titanium rotary files.
    Lee MH; Versluis A; Kim BM; Lee CJ; Hur B; Kim HC
    J Endod; 2011 Aug; 37(8):1152-7. PubMed ID: 21763912
    [TBL] [Abstract][Full Text] [Related]  

  • 62. [Shaping ability of multi-taper nickel-titanium files in simulated resin curved root canal].
    Luo HX; Huang DM; Jia LH; Luo SG; Gao XJ; Tan H; Zhou XD
    Hua Xi Kou Qiang Yi Xue Za Zhi; 2006 Aug; 24(4):339-42. PubMed ID: 16999355
    [TBL] [Abstract][Full Text] [Related]  

  • 63. Efficiency of rotary nickel-titanium FlexMaster instruments compared with stainless steel hand K-Flexofile--Part 2. Cleaning effectiveness and instrumentation results in severely curved root canals of extracted teeth.
    Schäfer E; Lohmann D
    Int Endod J; 2002 Jun; 35(6):514-21. PubMed ID: 12190908
    [TBL] [Abstract][Full Text] [Related]  

  • 64. Shaping ability of different nickel-titanium systems in simulated S-shaped canals with and without glide path.
    Bürklein S; Poschmann T; Schäfer E
    J Endod; 2014 Aug; 40(8):1231-4. PubMed ID: 25069939
    [TBL] [Abstract][Full Text] [Related]  

  • 65. Shaping ability of three nickel-titanium endodontic file systems in simulated S-shaped root canals.
    Burroughs JR; Bergeron BE; Roberts MD; Hagan JL; Himel VT
    J Endod; 2012 Dec; 38(12):1618-21. PubMed ID: 23146648
    [TBL] [Abstract][Full Text] [Related]  

  • 66. Comparison of preparation of curved root canals with Hyflex CM and Revo-S rotary nickel-titanium instruments.
    Bürklein S; Börjes L; Schäfer E
    Int Endod J; 2014 May; 47(5):470-6. PubMed ID: 23998461
    [TBL] [Abstract][Full Text] [Related]  

  • 67. Comparison of root canal transportation induced by three rotary systems with noncutting tips using computed tomography.
    Özer SY
    Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2011 Feb; 111(2):244-50. PubMed ID: 21167759
    [TBL] [Abstract][Full Text] [Related]  

  • 68. Preparation of severely curved simulated root canals using engine-driven rotary and conventional hand instruments.
    Szep S; Gerhardt T; Leitzbach C; Lüder W; Heidemann D
    Clin Oral Investig; 2001 Mar; 5(1):17-25. PubMed ID: 11355093
    [TBL] [Abstract][Full Text] [Related]  

  • 69. Influence of curvature location along an artificial canal on cyclic fatigue of a rotary nickel-titanium endodontic instrument.
    Lopes HP; Chiesa WM; Correia NR; de Souza Navegante NC; Elias CN; Moreira EJ; Chiesa BE
    Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2011 Jun; 111(6):792-6. PubMed ID: 21444222
    [TBL] [Abstract][Full Text] [Related]  

  • 70. Comparison of hand stainless steel and nickel titanium rotary instrumentation: a clinical study.
    Schäfer E; Schulz-Bongert U; Tulus G
    J Endod; 2004 Jun; 30(6):432-5. PubMed ID: 15167474
    [TBL] [Abstract][Full Text] [Related]  

  • 71. The shaping effects of three nickel-titanium rotary instruments in simulated S-shaped canals.
    Yoshimine Y; Ono M; Akamine A
    J Endod; 2005 May; 31(5):373-5. PubMed ID: 15851932
    [TBL] [Abstract][Full Text] [Related]  

  • 72. Shaping canals with ProFiles and K3 instruments: does operator experience matter?
    Al-Omari MA; Aurich T; Wirtti S
    Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2010 Sep; 110(3):e50-5. PubMed ID: 20580277
    [TBL] [Abstract][Full Text] [Related]  

  • 73. Comparison of three techniques for preparing oval-shaped root canals.
    Taha NA; Ozawa T; Messer HH
    J Endod; 2010 Mar; 36(3):532-5. PubMed ID: 20171378
    [TBL] [Abstract][Full Text] [Related]  

  • 74. An in vitro comparison of canal preparation using two automated rotary nickel-titanium instrumentation techniques.
    Jardine SJ; Gulabivala K
    Int Endod J; 2000 Jul; 33(4):381-91. PubMed ID: 11307215
    [TBL] [Abstract][Full Text] [Related]  

  • 75. Shaping ability of ProTaper NEXT and BT-RaCe nickel-titanium instruments in severely curved root canals.
    Bürklein S; Mathey D; Schäfer E
    Int Endod J; 2015 Aug; 48(8):774-81. PubMed ID: 25156248
    [TBL] [Abstract][Full Text] [Related]  

  • 76. Preparation of oval-shaped root canals in mandibular molars using nickel-titanium rotary instruments: a micro-computed tomography study.
    Paqué F; Balmer M; Attin T; Peters OA
    J Endod; 2010 Apr; 36(4):703-7. PubMed ID: 20307747
    [TBL] [Abstract][Full Text] [Related]  

  • 77. Comparison of cyclic fatigue resistance of used and new RaCe instruments.
    Aydin C; Inan U; Tunca YM
    Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2010 Mar; 109(3):e131-4. PubMed ID: 20219578
    [TBL] [Abstract][Full Text] [Related]  

  • 78. Comparative evaluation of the shaping ability of two different nickel-titanium rotary files in curved root canals of extracted human molar teeth.
    Ferrara G; Taschieri S; Corbella S; Ceci C; Del Fabbro M; Machtou P
    J Investig Clin Dent; 2017 Feb; 8(1):. PubMed ID: 26343421
    [TBL] [Abstract][Full Text] [Related]  

  • 79. Shaping of curved root canals instrumented with stainless steel and nickel titanium files.
    Atlas DM; Leonardi L; Raiden G
    Acta Odontol Latinoam; 2005; 18(1):23-30. PubMed ID: 16302457
    [TBL] [Abstract][Full Text] [Related]  

  • 80. Shaping ability of different single-file systems in severely curved root canals of extracted teeth.
    Bürklein S; Benten S; Schäfer E
    Int Endod J; 2013 Jun; 46(6):590-7. PubMed ID: 23240965
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 16.