These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

129 related articles for article (PubMed ID: 19994542)

  • 21. Analysis of post-exposure density growth in radiochromic film with respect to the radiation dose.
    Shima K; Tateoka K; Saitoh Y; Suzuki J; Yaegashi Y; Fujimoto K; Nakazawa T; Nakata A; Abe T; Imai S; Sakata K; Hareyama M
    J Radiat Res; 2012; 53(2):301-5. PubMed ID: 22245751
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Calibration of GafChromic EBT3 for absorbed dose measurements in 5 MeV proton beam and (60)Co γ-rays.
    Vadrucci M; Esposito G; Ronsivalle C; Cherubini R; Marracino F; Montereali RM; Picardi L; Piccinini M; Pimpinella M; Vincenti MA; De Angelis C
    Med Phys; 2015 Aug; 42(8):4678-84. PubMed ID: 26233195
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Evaluation of an Epson flatbed scanner to read Gafchromic EBT films for radiation dosimetry.
    Ferreira BC; Lopes MC; Capela M
    Phys Med Biol; 2009 Feb; 54(4):1073-85. PubMed ID: 19168937
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Investigation of energy dependence of EBT and EBT-2 gafchromic film.
    Lindsay P; Rink A; Ruschin M; Jaffray D
    Med Phys; 2010 Feb; 37(2):571-6. PubMed ID: 20229865
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Scanning orientation effects on Gafchromic EBT film dosimetry.
    Butson MJ; Cheung T; Yu PK
    Australas Phys Eng Sci Med; 2006 Sep; 29(3):281-4. PubMed ID: 17058592
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Dose and absorption spectra response of EBT2 Gafchromic film to high energy x-rays.
    Butson MJ; Cheung T; Yu PK; Alnawaf H
    Australas Phys Eng Sci Med; 2009 Dec; 32(4):196-202. PubMed ID: 20169838
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Clinical use of EBT model Gafchromic film in radiotherapy.
    Fiandra C; Ricardi U; Ragona R; Anglesio S; Giglioli FR; Calamia E; Lucio F
    Med Phys; 2006 Nov; 33(11):4314-9. PubMed ID: 17153410
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Measurement of high energy x-ray beam penumbra with Gafchromic EBT radiochromic film.
    Cheung T; Butson MJ; Yu PK
    Med Phys; 2006 Aug; 33(8):2912-4. PubMed ID: 16964868
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Quantitative investigation of the effects of the scanning parameters in the digitization of EBT and EBT2 Gafchromic film dosimetry with flatbed scanners.
    Hu Y; Ahmad S; Ali I
    J Xray Sci Technol; 2012; 20(4):385-93. PubMed ID: 23324780
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Dose and energy dependence of response of Gafchromic XR-QA film for kilovoltage x-ray beams.
    Rampado O; Garelli E; Deagostini S; Ropolo R
    Phys Med Biol; 2006 Jun; 51(11):2871-81. PubMed ID: 16723772
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Comparative dose evaluations between XVI and OBI cone beam CT systems using Gafchromic XRQA2 film and nanoDot optical stimulated luminescence dosimeters.
    Giaddui T; Cui Y; Galvin J; Yu Y; Xiao Y
    Med Phys; 2013 Jun; 40(6):062102. PubMed ID: 23718600
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Variations in dose distribution and optical properties of Gafchromic(TM) EBT2 film according to scanning mode.
    Park S; Kang SK; Cheong KH; Hwang T; Kim H; Han T; Lee MY; Kim K; Bae H; Su Kim H; Han Kim J; Jae Oh S; Suh JS
    Med Phys; 2012 May; 39(5):2524-35. PubMed ID: 22559623
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Analysis of uncertainties in Gafchromic EBT film dosimetry of photon beams.
    Martisíková M; Ackermann B; Jäkel O
    Phys Med Biol; 2008 Dec; 53(24):7013-27. PubMed ID: 19015581
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Intra-irradiation changes in the signal of polymer-based dosimeter (GAFCHROMIC EBT) due to dose rate variations.
    Rink A; Vitkin IA; Jaffray DA
    Phys Med Biol; 2007 Nov; 52(22):N523-9. PubMed ID: 17975282
    [TBL] [Abstract][Full Text] [Related]  

  • 35. LET dependence of GafChromic films and an ion chamber in low-energy proton dosimetry.
    Kirby D; Green S; Palmans H; Hugtenburg R; Wojnecki C; Parker D
    Phys Med Biol; 2010 Jan; 55(2):417-33. PubMed ID: 20019399
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Comparison of the epson expression 1680 flatbed and the vidar VXR-16 dosimetry PRO film scanners for use in IMRT dosimetry using gafchromic and radiographic film.
    Wilcox E; Daskalov G; Nedialkova L
    Med Phys; 2007 Jan; 34(1):41-8. PubMed ID: 17278488
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Evaluation of GafChromic EBT prototype B for external beam dose verification.
    Todorovic M; Fischer M; Cremers F; Thom E; Schmidt R
    Med Phys; 2006 May; 33(5):1321-8. PubMed ID: 16752567
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Role of water in the crystal structure of LiPCDA monomer and the radiotherapy dose response of EBT-3 film.
    Kaiyum R; Schruder CW; Mermut O; Rink A
    Med Phys; 2022 May; 49(5):3470-3480. PubMed ID: 35286716
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Absorption spectra of irradiated XRCT radiochromic film.
    Butson MJ; Cheung T; Yu PK
    Phys Med Biol; 2006 Jun; 51(12):3099-103. PubMed ID: 16757865
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Dosimetric properties of Gafchromic EBT films in monoenergetic medical ion beams.
    Martisíková M; Jäkel O
    Phys Med Biol; 2010 Jul; 55(13):3741-51. PubMed ID: 20530848
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.