These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
367 related articles for article (PubMed ID: 1999702)
41. Accuracy of pulse oximetry during arterial oxyhemoglobin desaturation in dogs. Sendak MJ; Harris AP; Donham RT Anesthesiology; 1988 Jan; 68(1):111-4. PubMed ID: 3337361 [TBL] [Abstract][Full Text] [Related]
42. Accuracy of pulse oximetry in children. Ross PA; Newth CJ; Khemani RG Pediatrics; 2014 Jan; 133(1):22-9. PubMed ID: 24344108 [TBL] [Abstract][Full Text] [Related]
43. Study of Oxygen Saturation by Pulse Oximetry and Arterial Blood Gas in ICU Patients: A Descriptive Cross-sectional Study. Rauniyar N; Pujari S; Shrestha P JNMA J Nepal Med Assoc; 2020 Oct; 58(230):789-793. PubMed ID: 34504355 [TBL] [Abstract][Full Text] [Related]
44. Dark skin decreases the accuracy of pulse oximeters at low oxygen saturation: the effects of oximeter probe type and gender. Feiner JR; Severinghaus JW; Bickler PE Anesth Analg; 2007 Dec; 105(6 Suppl):S18-S23. PubMed ID: 18048893 [TBL] [Abstract][Full Text] [Related]
45. Performance of popular pulse oximeters compared with simultaneous arterial oxygen saturation or clinical-grade pulse oximetry: a cross-sectional validation study in intensive care patients. Harskamp RE; Bekker L; Himmelreich JCL; De Clercq L; Karregat EPM; Sleeswijk ME; Lucassen WAM BMJ Open Respir Res; 2021 Sep; 8(1):. PubMed ID: 34489238 [TBL] [Abstract][Full Text] [Related]
46. Buccal pulse oximeter is more accurate than finger pulse oximeter in measuring oxygen saturation. O'Leary RJ; Landon M; Benumof JL Anesth Analg; 1992 Oct; 75(4):495-8. PubMed ID: 1530160 [TBL] [Abstract][Full Text] [Related]
47. Evaluation of the Ohmeda 3700 pulse oximeter. Warley AR; Mitchell JH; Stradling JR Thorax; 1987 Nov; 42(11):892-6. PubMed ID: 3424271 [TBL] [Abstract][Full Text] [Related]
48. Novel transcutaneous sensor combining optical tcPO van Weteringen W; Goos TG; van Essen T; Ellenberger C; Hayoz J; de Jonge RCJ; Reiss IKM; Schumacher PM Med Biol Eng Comput; 2020 Feb; 58(2):239-247. PubMed ID: 31741291 [TBL] [Abstract][Full Text] [Related]
49. A clinical evaluation of pulse oximetry during thoracic surgery. Desiderio DP; Wong G; Shah NK; Liu J; Loughlin CJ; Bedford RF J Cardiothorac Anesth; 1990 Feb; 4(1):30-4. PubMed ID: 2131852 [TBL] [Abstract][Full Text] [Related]
50. Factors affecting the performance of 5 cerebral oximeters during hypoxia in healthy volunteers. Bickler PE; Feiner JR; Rollins MD Anesth Analg; 2013 Oct; 117(4):813-823. PubMed ID: 24023027 [TBL] [Abstract][Full Text] [Related]
51. Dynamic in vivo response characteristics of three oximeters: Hewlett-Packard 47201A, Biox III, and Nellcor N-100. West P; George CF; Kryger MH Sleep; 1987 Jun; 10(3):263-71. PubMed ID: 3629089 [TBL] [Abstract][Full Text] [Related]
52. The feasibility of transesophageal echocardiograph-guided right and left ventricular oximetry in hemodynamically stable patients undergoing coronary artery bypass grafting. Margreiter J; Keller C; Brimacombe J Anesth Analg; 2002 Apr; 94(4):794-8, table of contents. PubMed ID: 11916775 [TBL] [Abstract][Full Text] [Related]
53. A two centre observational study of simultaneous pulse oximetry and arterial oxygen saturation recordings in intensive care unit patients. Ebmeier SJ; Barker M; Bacon M; Beasley RC; Bellomo R; Knee Chong C; Eastwood GM; Gilchrist J; Kagaya H; Pilcher J; Reddy SK; Ridgeon E; Sarma N; Sprogis S; Tanaka A; Tweedie M; Weatherall M; Young PJ Anaesth Intensive Care; 2018 May; 46(3):297-303. PubMed ID: 29716488 [TBL] [Abstract][Full Text] [Related]
54. Saturation by pulse oximetry: comparison of the results obtained by instruments of different brands. Thilo EH; Andersen D; Wasserstein ML; Schmidt J; Luckey D J Pediatr; 1993 Apr; 122(4):620-6. PubMed ID: 7681875 [TBL] [Abstract][Full Text] [Related]
55. Validation of pulse oximetry during progressive normobaric hypoxia utilizing a portable chamber. Kolb JC; Farran P; Norris SR; Smith D; Mester J Can J Appl Physiol; 2004 Feb; 29(1):3-15. PubMed ID: 15001800 [TBL] [Abstract][Full Text] [Related]
56. Accuracy of pulse oximeters at low oxygen saturations in children with congenital cyanotic heart disease: An observational study. Kim EH; Lee JH; Song IK; Kim HS; Jang YE; Yoo S; Kim JT Paediatr Anaesth; 2019 Jun; 29(6):597-603. PubMed ID: 30938906 [TBL] [Abstract][Full Text] [Related]
57. Clinical Outcomes Associated With Overestimation of Oxygen Saturation by Pulse Oximetry in Patients Hospitalized With COVID-19. Fawzy A; Wu TD; Wang K; Sands KE; Fisher AM; Arnold Egloff SA; DellaVolpe JD; Iwashyna TJ; Xu Y; Garibaldi BT JAMA Netw Open; 2023 Aug; 6(8):e2330856. PubMed ID: 37615985 [TBL] [Abstract][Full Text] [Related]