BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

204 related articles for article (PubMed ID: 20000499)

  • 1. Ultrafine particles in indoor air of a school: possible role of secondary organic aerosols.
    Morawska L; He C; Johnson G; Guo H; Uhde E; Ayoko G
    Environ Sci Technol; 2009 Dec; 43(24):9103-9. PubMed ID: 20000499
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Levels of ultrafine particles in different microenvironments--implications to children exposure.
    Diapouli E; Chaloulakou A; Spyrellis N
    Sci Total Environ; 2007 Dec; 388(1-3):128-36. PubMed ID: 17888492
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Characterizing and predicting ultrafine particle counts in Canadian classrooms during the winter months: model development and evaluation.
    Weichenthal S; Dufresne A; Infante-Rivard C; Joseph L
    Environ Res; 2008 Mar; 106(3):349-60. PubMed ID: 17919560
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Field evaluation of nanofilm detectors for measuring acidic particles in indoor and outdoor air.
    Cohen BS; Heikkinen MS; Hazi Y; Gao H; Peters P; Lippmann M
    Res Rep Health Eff Inst; 2004 Sep; (121):1-35; discussion 37-46. PubMed ID: 15553489
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Relationships of Indoor, Outdoor, and Personal Air (RIOPA). Part I. Collection methods and descriptive analyses.
    Weisel CP; Zhang J; Turpin BJ; Morandi MT; Colome S; Stock TH; Spektor DM; Korn L; Winer AM; Kwon J; Meng QY; Zhang L; Harrington R; Liu W; Reff A; Lee JH; Alimokhtari S; Mohan K; Shendell D; Jones J; Farrar L; Maberti S; Fan T
    Res Rep Health Eff Inst; 2005 Nov; (130 Pt 1):1-107; discussion 109-27. PubMed ID: 16454009
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison of outdoor and classroom ozone exposures for school children in Mexico City.
    Gold DR; Allen G; Damokosh A; Serrano P; Hayes C; Castillejos M
    J Air Waste Manag Assoc; 1996 Apr; 46(4):335-42. PubMed ID: 8901275
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Characterizing ultrafine particles and other air pollutants at five schools in South Texas.
    Zhang Q; Zhu Y
    Indoor Air; 2012 Feb; 22(1):33-42. PubMed ID: 21883490
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Ultrafine particles generated from coloring with scented markers in the presence of ozone.
    Fung CC; Shu S; Zhu Y
    Indoor Air; 2014 Oct; 24(5):503-10. PubMed ID: 24547888
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Long-term characterization of indoor and outdoor ultrafine particles at a commercial building.
    Wang Y; Hopke PK; Chalupa DC; Utell MJ
    Environ Sci Technol; 2010 Aug; 44(15):5775-80. PubMed ID: 20586487
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Indoor and outdoor submicrometer particles: exposure and epidemiologic relevance ("the 3 indoor Ls").
    Franck U; Tuch T; Manjarrez M; Wiedensohler A; Herbarth O
    Environ Toxicol; 2006 Dec; 21(6):606-13. PubMed ID: 17091505
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Relationship between outdoor and indoor air quality in eight French schools.
    Blondeau P; Iordache V; Poupard O; Genin D; Allard F
    Indoor Air; 2005 Feb; 15(1):2-12. PubMed ID: 15660564
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Outdoor and indoor UFP in primary schools across Barcelona.
    Reche C; Viana M; Rivas I; Bouso L; Àlvarez-Pedrerol M; Alastuey A; Sunyer J; Querol X
    Sci Total Environ; 2014 Sep; 493():943-53. PubMed ID: 25003584
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Indoor air quality investigation according to age of the school buildings in Korea.
    Sohn J; Yang W; Kim J; Son B; Park J
    J Environ Manage; 2009 Jan; 90(1):348-54. PubMed ID: 18079045
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Air concentrations of VOCs in portable and traditional classrooms: results of a pilot study in Los Angeles County.
    Shendell DG; Winer AM; Stock TH; Zhang L; Zhang JJ; Maberti S; Colome SD
    J Expo Anal Environ Epidemiol; 2004 Jan; 14(1):44-59. PubMed ID: 14726944
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Physical parameters effect on ozone-initiated formation of indoor secondary organic aerosols with emissions from cleaning products.
    Huang Y; Ho KF; Ho SS; Lee SC; Yau PS; Cheng Y
    J Hazard Mater; 2011 Sep; 192(3):1787-94. PubMed ID: 21798666
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Particulate matter in indoor environments--exposure situation in residences, schools, pubs, and related recreational spaces].
    Fromme H
    Gesundheitswesen; 2006 Nov; 68(11):714-23. PubMed ID: 17199207
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Characterization of fine particulate matter in Ohio: indoor, outdoor, and personal exposures.
    Crist KC; Liu B; Kim M; Deshpande SR; John K
    Environ Res; 2008 Jan; 106(1):62-71. PubMed ID: 17765218
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Daily mortality and fine and ultrafine particles in Erfurt, Germany part I: role of particle number and particle mass.
    Wichmann HE; Spix C; Tuch T; Wölke G; Peters A; Heinrich J; Kreyling WG; Heyder J
    Res Rep Health Eff Inst; 2000 Nov; (98):5-86; discussion 87-94. PubMed ID: 11918089
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Indoor air quality in a middle school, Part II: Development of emission factors for particulate matter and bioaerosols.
    Scheff PA; Paulius VK; Curtis L; Conroy LM
    Appl Occup Environ Hyg; 2000 Nov; 15(11):835-42. PubMed ID: 11062928
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Lung deposition of fine and ultrafine particles outdoors and indoors during a cooking event and a no activity period.
    Mitsakou C; Housiadas C; Eleftheriadis K; Vratolis S; Helmis C; Asimakopoulos D
    Indoor Air; 2007 Apr; 17(2):143-52. PubMed ID: 17391237
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.