These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

92 related articles for article (PubMed ID: 20003019)

  • 1. Safety and feasibility of real time adenosine myocardial contrast echocardiography with emphasis on induction of arrhythmias: a study in healthy volunteers and patients with stable coronary artery disease.
    Dijkmans PA; Juffermans LJ; van Dijk J; Musters RJ; Spreeuwenberg ; Kamp O
    Echocardiography; 2009 Aug; 26(7):807-14. PubMed ID: 20003019
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of sulfur hexafluoride microbubble (SonoVue)-enhanced myocardial contrast echocardiography with gated single-photon emission computed tomography for detection of significant coronary artery disease: a large European multicenter study.
    Senior R; Moreo A; Gaibazzi N; Agati L; Tiemann K; Shivalkar B; von Bardeleben S; Galiuto L; Lardoux H; Trocino G; Carrió I; Le Guludec D; Sambuceti G; Becher H; Colonna P; Ten Cate F; Bramucci E; Cohen A; Bezante G; Aggeli C; Kasprzak JD
    J Am Coll Cardiol; 2013 Oct; 62(15):1353-61. PubMed ID: 23770168
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Quantitative myocardial contrast supine bicycle stress echocardiography for detection of coronary artery disease.
    Miszalski-Jamka T; Kuntz-Hehner S; Tiemann K; Karwat K; Kostkiewicz M
    Echocardiography; 2013 Apr; 30(4):392-400. PubMed ID: 23252652
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Real time myocardial contrast echocardiography during supine bicycle stress and continuous infusion of contrast agent. Cutoff values for myocardial contrast replenishment discriminating abnormal myocardial perfusion.
    Miszalski-Jamka T; Kuntz-Hehner S; Schmidt H; Hammerstingl C; Tiemann K; Ghanem A; Troatz C; Lüderitz B; Omran H
    Echocardiography; 2007 Jul; 24(6):638-48. PubMed ID: 17584204
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Quantitative adenosine real-time myocardial contrast echocardiography for detection of angiographically significant coronary artery disease.
    Malm S; Frigstad S; Torp H; Wiseth R; Skjarpe T
    J Am Soc Echocardiogr; 2006 Apr; 19(4):365-72. PubMed ID: 16581474
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Real-time myocardial contrast echocardiography for pharmacologic stress testing: is quantitative estimation of myocardial blood flow reserve necessary?
    Korosoglou G; da Silva KG; Labadze N; Dubart AE; Hansen A; Rosenberg M; Zehelein J; Kuecherer H
    J Am Soc Echocardiogr; 2004 Jan; 17(1):1-9. PubMed ID: 14712180
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Accelerated stress real-time myocardial contrast echocardiography for the detection of coronary artery disease: comparison with 99mTc single photon emission computed tomography.
    Lipiec P; Wejner-Mik P; Krzemińska-Pakuła M; Kuśmierek J; Płachcińska A; Szumiński R; Peruga JZ; Kasprzak JD
    J Am Soc Echocardiogr; 2008 Aug; 21(8):941-7. PubMed ID: 18385014
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Myocardial contrast echocardiography (MCE) with triggered ultrasound does not cause premature ventricular complexes: evidence from PB127 MCE studies.
    Raisinghani A; Wei KS; Crouse L; Villanueva F; Feigenbaum H; Schiller NB; Weiss J; Naqvi TZ; Siegel R; Monaghan M; Goldman JH; Demaria A;
    J Am Soc Echocardiogr; 2003 Oct; 16(10):1037-42. PubMed ID: 14566296
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Myocardial blood volume and perfusion reserve responses to combined dipyridamole and exercise stress: a quantitative approach to contrast stress echocardiography.
    Moir S; Haluska BA; Jenkins C; McNab D; Marwick TH
    J Am Soc Echocardiogr; 2005 Nov; 18(11):1187-93. PubMed ID: 16275528
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The feasibility and clinical utility of myocardial contrast echocardiography in clinical practice: results from the incorporation of myocardial perfusion assessment into clinical testing with stress echocardiography study.
    Shah BN; Chahal NS; Bhattacharyya S; Li W; Roussin I; Khattar RS; Senior R
    J Am Soc Echocardiogr; 2014 May; 27(5):520-30. PubMed ID: 24637056
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Quantification of resting myocardial blood flow velocity in normal humans using real-time contrast echocardiography. A feasibility study.
    Malm S; Frigstad S; Helland F; Oye K; Slordahl S; Skjarpe T
    Cardiovasc Ultrasound; 2005 Jun; 3():16. PubMed ID: 15958173
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The diagnostic value of adenosine stress-contrast echocardiography for diagnosis of coronary artery disease in hypertensive patients: comparison to Tl-201 single-photon emission computed tomography.
    Aggeli C; Christoforatou E; Giannopoulos G; Roussakis G; Kokkinakis C; Barbetseas J; Vlachopoulos C; Stefanadis C
    Am J Hypertens; 2007 May; 20(5):533-8. PubMed ID: 17485016
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Myocardial perfusion assessment in patients with medium probability of coronary artery disease and no prior myocardial infarction: comparison of myocardial contrast echocardiography with 99mTc single-photon emission computed tomography.
    Senior R; Lepper W; Pasquet A; Chung G; Hoffman R; Vanoverschelde JL; Cerqueira M; Kaul S
    Am Heart J; 2004 Jun; 147(6):1100-5. PubMed ID: 15199362
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Reproducible Computer-Assisted Quantification of Myocardial Perfusion with Contrast-Enhanced Ultrasound.
    Li Y; Chahal N; Senior R; Tang MX
    Ultrasound Med Biol; 2017 Oct; 43(10):2235-2246. PubMed ID: 28693906
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Diagnosis of ischaemic heart disease by myocardial contrast echocardiography during supine bicycle stress.
    Miszalski-Jamka T; Kuntz-Hehner S; Schmidt H; Jost P; Luderitz B; Omran H
    Kardiol Pol; 2006 Apr; 64(4):355-61; discussion 362-3. PubMed ID: 16699976
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Impact of previous myocardial infarction on the incremental value of myocardial contrast to two-dimensional supine bicycle stress echocardiography in evaluation of coronary artery disease.
    Miszalski-Jamka T; Kuntz-Hehner S; Schmidt H; Miszalski-Jamka K; Hammerstingl C; Tiemann K; Ghanem A; Troatz C; Pasowicz M; Lüderitz B; Omran H
    Int J Cardiol; 2009 Jul; 136(1):47-55. PubMed ID: 18675474
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Absolute myocardial blood flow determination using real-time myocardial contrast echocardiography during adenosine stress: comparison with single-photon emission computed tomography.
    Abdelmoneim SS; Dhoble A; Bernier M; Moir S; Hagen ME; Ness SA; Abdel-Kader SS; Pellikka PA; Mulvagh SL
    Heart; 2009 Oct; 95(20):1662-8. PubMed ID: 19584062
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The quantification of absolute myocardial perfusion in humans by contrast echocardiography: algorithm and validation.
    Vogel R; Indermühle A; Reinhardt J; Meier P; Siegrist PT; Namdar M; Kaufmann PA; Seiler C
    J Am Coll Cardiol; 2005 Mar; 45(5):754-62. PubMed ID: 15734622
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Myocardial contrast echocardiography for the detection of coronary artery stenosis: a prospective multicenter study in comparison with single-photon emission computed tomography.
    Jeetley P; Hickman M; Kamp O; Lang RM; Thomas JD; Vannan MA; Vanoverschelde JL; van der Wouw PA; Senior R
    J Am Coll Cardiol; 2006 Jan; 47(1):141-5. PubMed ID: 16386678
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Contrast stress echocardiography for the diagnosis of coronary artery disease in patients with chest pain but without acute coronary syndrome: incremental value of myocardial perfusion.
    Gaibazzi N; Reverberi C; Squeri A; De Iaco G; Ardissino D; Gherli T
    J Am Soc Echocardiogr; 2009 Apr; 22(4):404-10. PubMed ID: 19345309
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.