These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

91 related articles for article (PubMed ID: 20007795)

  • 1. Relationship of inspiratory and expiratory times to upper airway resistance during pulsatile needle cricothyrotomy ventilation with generic delivery circuit.
    Lim MW; Benham SW
    Br J Anaesth; 2010 Jan; 104(1):98-107. PubMed ID: 20007795
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The efficacy of spontaneous and controlled ventilation with various cricothyrotomy devices: a quantitative in vitro assessment in a model lung.
    Michalek-Sauberer A; Granegger M; Gilly H
    J Trauma; 2011 Oct; 71(4):886-92. PubMed ID: 21399543
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Ventilation of a model lung using various cricothyrotomy devices.
    Craven RM; Vanner RG
    Anaesthesia; 2004 Jun; 59(6):595-9. PubMed ID: 15144301
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Ventilation through a small-bore catheter: optimizing expiratory ventilation assistance.
    Hamaekers AE; Borg PA; Götz T; Enk D
    Br J Anaesth; 2011 Mar; 106(3):403-9. PubMed ID: 21177698
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Compensating Artificial Airway Resistance via Active Expiration Assistance.
    Wirth S; Seywert L; Spaeth J; Schumann S
    Respir Care; 2016 Dec; 61(12):1597-1604. PubMed ID: 27555619
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Monitoring tidal volumes when using the Ventrain® emergency ventilator].
    Schmidt AR; Ruetzler K; Haas T; Schmitz A; Weiss M
    Anaesthesist; 2016 Jul; 65(7):514-20. PubMed ID: 27245923
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Needle cricothyrotomy.
    Mace SE; Khan N
    Emerg Med Clin North Am; 2008 Nov; 26(4):1085-101, xi. PubMed ID: 19059102
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of different methods of ventilation via cannula cricothyroidotomy in a trachea-lung model.
    Flint NJ; Russell WC; Thompson JP
    Br J Anaesth; 2009 Dec; 103(6):891-5. PubMed ID: 19797248
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The impact of imposed expiratory resistance in neonatal mechanical ventilation: a laboratory evaluation.
    DiBlasi RM; Salyer JW; Zignego JC; Redding GJ; Richardson CP
    Respir Care; 2008 Nov; 53(11):1450-60. PubMed ID: 18957147
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Case report: dealing with a ventilation complication after successful cricothyrotomy.
    Kei J; Dohrenwend PB
    J Emerg Med; 2013 May; 44(5):936-8. PubMed ID: 23200764
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Subglottic airway access: cricothyrotomy].
    Cortiñas Díaz J; López-de Abajo Rodríguez B; Costa Mourullo J
    Rev Esp Anestesiol Reanim; 2011 Dec; 58(10):595-601. PubMed ID: 22263404
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Two patients with CICV (cannot intubate cannot ventilate) rescued by cricothyrotomy].
    Morishima K; Kurita S; Yamama Y; Nakatani K
    Masui; 2013 Dec; 62(12):1406-9. PubMed ID: 24498769
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Emergency cricothyrotomy in infants--evaluation of a novel device in an animal model.
    Metterlein T; Frommer M; Kwok P; Lyer S; Graf BM; Sinner B
    Paediatr Anaesth; 2011 Feb; 21(2):104-9. PubMed ID: 21210882
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Simulation of late inspiratory rise in airway pressure during pressure support ventilation.
    Yu CH; Su PL; Lin WC; Lin SH; Chen CW
    Respir Care; 2015 Feb; 60(2):201-9. PubMed ID: 25371401
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Bench study on active exhalation valve performance.
    Jiao GY; Newhart JW
    Respir Care; 2008 Dec; 53(12):1697-702. PubMed ID: 19025705
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A new expiratory support system for resolving air trapping in lungs during mechanical ventilation: a lung model study.
    Uchiyama A; Nishimura M; Amata M; Mashimo T; Fujino Y
    Technol Health Care; 2007; 15(3):213-20. PubMed ID: 17473401
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Variation in inspiratory time and tidal volume with T-piece neonatal resuscitator: association with operator experience and distraction.
    McHale S; Thomas M; Hayden E; Bergin K; McCallion N; Molloy EJ
    Resuscitation; 2008 Nov; 79(2):230-3. PubMed ID: 18691802
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of inspiratory and expiratory resistance and reactance in patients with asthma and chronic obstructive pulmonary disease.
    Paredi P; Goldman M; Alamen A; Ausin P; Usmani OS; Pride NB; Barnes PJ
    Thorax; 2010 Mar; 65(3):263-7. PubMed ID: 20335298
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Elective use of an uncuffed small-bore cricothyrotomy tube with balloon occlusion of the subglottic airway.
    Suzuki T; Ikeda H; Iwamoto T; Sano H; Hashimoto M; Oe K; Inoue H; Serada K
    Can J Anaesth; 2014 Jan; 61(1):39-45. PubMed ID: 24158854
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A randomized trial comparing two cuffed emergency cricothyrotomy devices using a wire-guided and a catheter-over-needle technique.
    Metterlein T; Frommer M; Ginzkey C; Becher J; Schuster F; Roewer N; Kranke P
    J Emerg Med; 2011 Sep; 41(3):326-32. PubMed ID: 20605389
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.