These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

131 related articles for article (PubMed ID: 20012244)

  • 21. Tracheal rupture after endotracheal intubation: experience with management in 13 cases.
    Sippel M; Putensen C; Hirner A; Wolff M
    Thorac Cardiovasc Surg; 2006 Feb; 54(1):51-6. PubMed ID: 16485190
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Defective disposable endotracheal tube.
    Chiu TM; Meyers EF
    Anesth Analg; 1976; 55(3):437. PubMed ID: 945025
    [No Abstract]   [Full Text] [Related]  

  • 23. A comparison of cervical spine motion during orotracheal intubation with the trachlight(r) or the flexible fiberoptic bronchoscope.
    Houde BJ; Williams SR; Cadrin-Chênevert A; Guilbert F; Drolet P
    Anesth Analg; 2009 May; 108(5):1638-43. PubMed ID: 19372349
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Flexometalic endotraqueal tube burn in laser surgery.
    Sanchez D; Serrano C; León MC
    Rev Esp Anestesiol Reanim; 2017; 64(6):362-363. PubMed ID: 28385293
    [No Abstract]   [Full Text] [Related]  

  • 25. A complication of a closed-tube endotracheal suction catheter.
    Iannuzzi M; De Robertis E; Rispoli F; Piazza O; Tufano R
    Eur J Anaesthesiol; 2009 Nov; 26(11):974-5. PubMed ID: 19713858
    [No Abstract]   [Full Text] [Related]  

  • 26. Tracheal foreign body after laser supraglottoplasty: a hidden but risky complication of an aluminum foil tape-wrapped endotracheal tube.
    Soong WJ; Lee YS; Soong YH; Tsao PC; Yang CF; Jeng MJ; Peng YY
    Int J Pediatr Otorhinolaryngol; 2010 Dec; 74(12):1432-4. PubMed ID: 20934755
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Endoscopic study of mechanisms of failure of endotracheal tube advancement into the trachea during awake fiberoptic orotracheal intubation.
    Johnson DM; From AM; Smith RB; From RP; Maktabi MA
    Anesthesiology; 2005 May; 102(5):910-4. PubMed ID: 15851876
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Persistent tracheal dilatation: onset after brief mechanical ventilation with a "soft-cuff" endotracheal tube.
    Honig EG; Francis PB
    South Med J; 1979 Apr; 72(4):487-90. PubMed ID: 432692
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Tracheal injury using a gum elastic bougie within a RAE endotracheal tube.
    Prasad MM; Lim KS; Kumar CM
    Anaesth Intensive Care; 2016 May; 44(3):428. PubMed ID: 27246946
    [No Abstract]   [Full Text] [Related]  

  • 30. An Unnoticed Broken Sheathed Metallic Stylet in an Endotracheal Tube: A case report.
    Sharma PK; Khan RM; Kaul N
    Sultan Qaboos Univ Med J; 2010 Apr; 10(1):126-8. PubMed ID: 21509094
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Tracheobronchial foreign body management in an acutely ill neonate.
    Shapiro NL; Kaselonis GL
    Int J Pediatr Otorhinolaryngol; 2000 Jan; 52(1):75-7. PubMed ID: 10699243
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Effect of Use of a Bougie vs Endotracheal Tube and Stylet on First-Attempt Intubation Success Among Patients With Difficult Airways Undergoing Emergency Intubation: A Randomized Clinical Trial.
    Driver BE; Prekker ME; Klein LR; Reardon RF; Miner JR; Fagerstrom ET; Cleghorn MR; McGill JW; Cole JB
    JAMA; 2018 Jun; 319(21):2179-2189. PubMed ID: 29800096
    [TBL] [Abstract][Full Text] [Related]  

  • 33. [Foreign body in airway after assisted Frova guide intubation].
    Bona Gracia C; Vallés Torres J; Ferrer Ferrer M; Casans Francés R
    Rev Esp Anestesiol Reanim; 2015 Oct; 62(8):483. PubMed ID: 25687943
    [No Abstract]   [Full Text] [Related]  

  • 34. An unusual foreign body of the esophagus.
    Er M
    Asian Cardiovasc Thorac Ann; 2005 Mar; 13(1):70-1. PubMed ID: 15793056
    [TBL] [Abstract][Full Text] [Related]  

  • 35. The obstruction of an endotracheal tube by the plastic coating sheared from a stylet: a revisit.
    Bhargava M; Pothula SN; Joshi S
    Anesthesiology; 1998 Feb; 88(2):548-9. PubMed ID: 9477085
    [No Abstract]   [Full Text] [Related]  

  • 36. Removal of tracheobronchial foreign bodies in adults using flexible bronchoscopy: experience 1995-2006.
    Mise K; Jurcev Savicevic A; Pavlov N; Jankovic S
    Surg Endosc; 2009 Jun; 23(6):1360-4. PubMed ID: 18923871
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Tracheal injury: late symptom after double-lumen tube intubation - A case report.
    Ozdamar D; Turna C; Kibar A; Aksu C
    J Pak Med Assoc; 2018 Nov; 68(11):1711-1713. PubMed ID: 30410156
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Flexible fiberoptic bronchoscopy in the management of tracheobronchial foreign bodies in children: the value of a combined approach with open tube bronchoscopy.
    Wood RE; Gauderer MW
    J Pediatr Surg; 1984 Dec; 19(6):693-8. PubMed ID: 6520673
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Tracheal stenosis. A method of dilation with use of the fiberoptic bronchoscope.
    Goldman MH; Barsamian EM; Woods M; Sanders JH; Rosenkaimer SW; Schonmetzler HK
    Arch Surg; 1976 May; 111(5):554-6. PubMed ID: 1267603
    [TBL] [Abstract][Full Text] [Related]  

  • 40. [Rupture of the trachea caused by an endotracheal tube balloon].
    Elman A; Hay JM; Konrat N; Maillard JN
    Ann Chir Thorac Cardiovasc; 1973 Oct; 12(4):423-5. PubMed ID: 4771724
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.