BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

143 related articles for article (PubMed ID: 20014462)

  • 1. Percutaneous transgastric computed tomography-guided biopsy of the pancreas using large needles.
    Tseng HS; Chen CY; Chan WP; Chiang JH
    World J Gastroenterol; 2009 Dec; 15(47):5972-5. PubMed ID: 20014462
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The role of percutaneous biopsy in detection of pancreatic transplant rejection.
    Lee BC; McGahan JP; Perez RV; Boone JM
    Clin Transplant; 2000 Oct; 14(5):493-8. PubMed ID: 11048995
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Adequacy and complications of computed tomography-guided core needle biopsy on non-small cell lung cancers for epidermal growth factor receptor mutations demonstration: 18-gauge or 20-gauge biopsy needle.
    Cheung YC; Chang JW; Hsieh JJ; Lin G; Tsai YH
    Lung Cancer; 2010 Feb; 67(2):166-9. PubMed ID: 19450892
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Computed tomography-guided percutaneous core needle biopsy in pancreatic tumor diagnosis.
    Tyng CJ; Almeida MF; Barbosa PN; Bitencourt AG; Berg JA; Maciel MS; Coimbra FJ; Schiavon LH; Begnami MD; Guimarães MD; Zurstrassen CE; Chojniak R
    World J Gastroenterol; 2015 Mar; 21(12):3579-86. PubMed ID: 25834323
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Feasibility and safety of CT-guided percutaneous needle biopsy and subsequent iodine-125 seed interstitial implantation for pancreatic cancer].
    Yu YP; Jiang HT; Yao Z; Xia QR; Hong FM; Zeng H; Li S
    Zhonghua Zhong Liu Za Zhi; 2013 Aug; 35(8):608-12. PubMed ID: 24314220
    [TBL] [Abstract][Full Text] [Related]  

  • 6. CT-guided percutaneous biopsy of pancreas transplants.
    Aideyan OA; Schmidt AJ; Trenkner SW; Hakim NS; Gruessner RW; Walsh JW
    Radiology; 1996 Dec; 201(3):825-8. PubMed ID: 8939238
    [TBL] [Abstract][Full Text] [Related]  

  • 7. CT-guided percutaneous core-needle biopsy of pancreatic masses: comparison of the standard mesenteric/retroperitoneal versus the trans-organ approaches.
    Hsu MY; Pan KT; Chen CM; Lui KW; Chu SY; Lin YY; Hung CF; Huang YT; Tseng JH
    Clin Radiol; 2016 Jun; 71(6):507-12. PubMed ID: 27040800
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Image-Guided Percutaneous Biopsy for Pancreatic Lesions: 10-Year Experience in a Tertiary Cancer Center.
    Stella SF; Van Borsel M; Markose G; Nair SB
    Can Assoc Radiol J; 2019 May; 70(2):199-203. PubMed ID: 30894286
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Pancreatic transplants: CT-guided biopsy.
    Bernardino M; Fernandez M; Neylan J; Hertzler G; Whelchel J; Olson R
    Radiology; 1990 Dec; 177(3):709-11. PubMed ID: 2243974
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Lack of tumor seeding of hepatocellular carcinoma after percutaneous needle biopsy using coaxial cutting needle technique.
    Maturen KE; Nghiem HV; Marrero JA; Hussain HK; Higgins EG; Fox GA; Francis IR
    AJR Am J Roentgenol; 2006 Nov; 187(5):1184-7. PubMed ID: 17056903
    [TBL] [Abstract][Full Text] [Related]  

  • 11. CT-guided percutaneous biopsy of suspect pancreatic lesions: radiological and clinical outcome.
    Gruber-Rouh T; Langenbach MC; Eichler K; Vogl TJ; Yel I; Beeres M
    Clin Radiol; 2019 Nov; 74(11):899.e7-899.e12. PubMed ID: 31495545
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Application of a single needle type for all image-guided biopsies: results of 100 consecutive core biopsies in various organs using a novel tri-axial, end-cut needle.
    Diederich S; Padge B; Vossas U; Hake R; Eidt S
    Cancer Imaging; 2006 Jun; 6(1):43-50. PubMed ID: 16766268
    [TBL] [Abstract][Full Text] [Related]  

  • 13. 1.0T MR-guided percutaneous coaxial cutting needle biopsy in pancreatic lesion diagnosis.
    Liu C; Wang L; He X; Xu Y; Lu D; Li P; Lv R; Feng Y; Liu M; Li C
    J Magn Reson Imaging; 2018 Aug; 48(2):382-388. PubMed ID: 29319916
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Are percutaneous transgastric biopsies using 14-, 16- and 18-G Tru-Cut needles safe? An experimental study in the rabbit.
    Akan H; Ozen N; Incesu L; Gümüş S; Güneş M
    Australas Radiol; 1998 May; 42(2):99-101. PubMed ID: 9599821
    [TBL] [Abstract][Full Text] [Related]  

  • 15. CT-guided transthoracic needle biopsy of pulmonary nodules smaller than 20 mm: results with an automated 20-gauge coaxial cutting needle.
    Laurent F; Latrabe V; Vergier B; Montaudon M; Vernejoux JM; Dubrez J
    Clin Radiol; 2000 Apr; 55(4):281-7. PubMed ID: 10767187
    [TBL] [Abstract][Full Text] [Related]  

  • 16. CT-guided percutaneous needle biopsy of intrathoracic lesions by using the transsternal approach: experience in 37 patients.
    Gupta S; Wallace MJ; Morello FA; Ahrar K; Hicks ME
    Radiology; 2002 Jan; 222(1):57-62. PubMed ID: 11756705
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [CT-guided percutaneous biopsies for the classification of focal liver lesions: a comparison between 14 G and 18 G puncture biopsy needles].
    Haage P; Piroth W; Staatz G; Adam G; Günther RW
    Rofo; 1999 Jul; 171(1):44-8. PubMed ID: 10464504
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Percutaneous biopsy of periarterial soft tissue cuffs in the diagnosis of pancreatic carcinoma.
    O'Connell MJ; Paulson EK; Jaffe TA; Ho LM
    Abdom Imaging; 2004; 29(1):115-9. PubMed ID: 15160764
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Adequacy and complications of CT-guided percutaneous biopsy: a study of 334 cases in Srinagarind Hospital.
    Laopaiboon V; Aphinives C; Suporntreetriped K
    J Med Assoc Thai; 2009 Jul; 92(7):939-46. PubMed ID: 19626814
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Endoscopic ultrasound-guided, 18-gauge, fine needle aspiration biopsy of the pancreas using a 2.8 mm channel convex array echoendoscope.
    Binmoeller KF; Thul R; Rathod V; Henke P; Brand B; Jabusch HC; Soehendra N
    Gastrointest Endosc; 1998 Feb; 47(2):121-7. PubMed ID: 9512275
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.