BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

172 related articles for article (PubMed ID: 20017001)

  • 1. Diagnostic accuracy of 64-slice computed tomography coronary angiography in a large population of patients without revascularisation: registry data and review of multicentre trials.
    Maffei E; Palumbo A; Martini C; Meijboom W; Tedeschi C; Spagnolo P; Zuccarelli A; Weustink A; Torri T; Mollet N; Seitun S; Krestin GP; Cademartiri F
    Radiol Med; 2010 Apr; 115(3):368-84. PubMed ID: 20017001
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Diagnostic accuracy of 64-slice computed tomography coronary angiography in a large population of patients without revascularisation: registry data on the comparison between male and female population.
    Maffei E; Martini C; Tedeschi C; Spagnolo P; Zuccarelli A; Arcadi T; Guaricci A; Seitun S; Weustink A; Mollet N; Cademartiri F
    Radiol Med; 2012 Feb; 117(1):6-18. PubMed ID: 21643636
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Diagnostic accuracy of 64-slice computed tomography coronary angiography in a large population of patients without revascularisation: registry data on the impact of calcium score.
    Maffei E; Martini C; Tedeschi C; Spagnolo P; Zuccarelli A; Arcadi T; Guaricci A; Seitun S; Weustink A; Mollet N; Cademartiri F
    Radiol Med; 2011 Oct; 116(7):1000-13. PubMed ID: 21431299
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Diagnostic accuracy of 64-slice computed tomography coronary angiography in a large population of patients without revascularisation: registry data in NSTEMI acute coronary syndrome and influence of gender and risk factors.
    Maffei E; Martini C; Tedeschi C; Spagnolo P; Zuccarelli A; Arcadi T; Guaricci A; Seitun S; Weustink AC; Mollet NR; Cademartiri F
    Radiol Med; 2011 Oct; 116(7):1014-26. PubMed ID: 21643633
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Dual-source versus 64-section CT coronary angiography at lower heart rates: comparison of accuracy and radiation dose.
    Baumüller S; Leschka S; Desbiolles L; Stolzmann P; Scheffel H; Seifert B; Marincek B; Alkadhi H
    Radiology; 2009 Oct; 253(1):56-64. PubMed ID: 19587311
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The diagnostic accuracy, image quality and radiation dose of 64-slice dual-source CT in daily practice: a single institution's experience.
    Moon JH; Park EA; Lee W; Yin YH; Chung JW; Park JH; Lee HY; Kang HJ; Kim HS
    Korean J Radiol; 2011; 12(3):308-18. PubMed ID: 21603290
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Noninvasive coronary angiography by 320-row computed tomography with lower radiation exposure and maintained diagnostic accuracy: comparison of results with cardiac catheterization in a head-to-head pilot investigation.
    Dewey M; Zimmermann E; Deissenrieder F; Laule M; Dübel HP; Schlattmann P; Knebel F; Rutsch W; Hamm B
    Circulation; 2009 Sep; 120(10):867-75. PubMed ID: 19704093
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Diagnostic accuracy of dual-source CT coronary angiography: The effect of average heart rate, heart rate variability, and calcium score in a clinical perspective.
    Zhang LJ; Wu SY; Wang J; Lu Y; Zhang ZL; Jiang SS; Zhou CS; Lu GM
    Acta Radiol; 2010 Sep; 51(7):727-40. PubMed ID: 20707657
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Diagnostic performance of 64-slice computed tomography coronary angiography to detect significant coronary artery stenosis.
    Bayrak F; Guneysu T; Gemici G; Sevinc D; Mutlu B; Aytaclar S; Degertekin M
    Acta Cardiol; 2008 Feb; 63(1):11-7. PubMed ID: 18372575
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Systematic review of the clinical effectiveness and cost-effectiveness of 64-slice or higher computed tomography angiography as an alternative to invasive coronary angiography in the investigation of coronary artery disease.
    Mowatt G; Cummins E; Waugh N; Walker S; Cook J; Jia X; Hillis GS; Fraser C
    Health Technol Assess; 2008 May; 12(17):iii-iv, ix-143. PubMed ID: 18462576
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Stress-ECG vs. CT coronary angiography for the diagnosis of coronary artery disease: a "real-world" experience.
    Maffei E; Palumbo A; Martini C; Cuttone A; Ugo F; Emiliano E; Menozzi A; Vignali L; Brambilla V; Coruzzi P; Weustink A; Mollet N; Ardissino D; Reverberi C; Crisi G; Cademartiri F
    Radiol Med; 2010 Apr; 115(3):354-67. PubMed ID: 19902329
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Impact of SSF on Diagnostic Performance of Coronary Computed Tomography Angiography Within 1 Heart Beat in Patients With High Heart Rate Using a 256-Row Detector Computed Tomography.
    Liang J; Wang H; Xu L; Dong L; Fan Z; Wang R; Sun Z
    J Comput Assist Tomogr; 2018; 42(1):54-61. PubMed ID: 28708724
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Diagnostic performance of 64-multidetector row coronary computed tomographic angiography for evaluation of coronary artery stenosis in individuals without known coronary artery disease: results from the prospective multicenter ACCURACY (Assessment by Coronary Computed Tomographic Angiography of Individuals Undergoing Invasive Coronary Angiography) trial.
    Budoff MJ; Dowe D; Jollis JG; Gitter M; Sutherland J; Halamert E; Scherer M; Bellinger R; Martin A; Benton R; Delago A; Min JK
    J Am Coll Cardiol; 2008 Nov; 52(21):1724-32. PubMed ID: 19007693
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Accuracy and rate of coronary artery segment visualization with CT angiography for the non-invasive detection of coronary artery stenoses.
    Bordeleau E; Lamonde A; Prenovault J; Belblidia A; Coté G; Lespérance J; Soulez G; Chartrand-Lefebvre C
    Int J Cardiovasc Imaging; 2007 Dec; 23(6):771-80. PubMed ID: 17216125
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Accuracy of coronary artery stenosis detection with CT versus conventional coronary angiography compared with composite findings from both tests as an enhanced reference standard.
    Kerl JM; Schoepf UJ; Zwerner PL; Bauer RW; Abro JA; Thilo C; Vogl TJ; Herzog C
    Eur Radiol; 2011 Sep; 21(9):1895-903. PubMed ID: 21533864
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Diagnostic accuracy of second-generation dual-source computed tomography coronary angiography with iterative reconstructions: a real-world experience.
    Maffei E; Martini C; Rossi A; Mollet N; Lario C; Castiglione Morelli M; Clemente A; Gentile G; Arcadi T; Seitun S; Catalano O; Aldrovandi A; Cademartiri F
    Radiol Med; 2012 Aug; 117(5):725-38. PubMed ID: 22095423
    [TBL] [Abstract][Full Text] [Related]  

  • 17. 64-slice computed tomography coronary angiography: diagnostic accuracy in the real world.
    Cademartiri F; Maffei E; Notarangelo F; Ugo F; Palumbo A; Lina D; Aldrovandi A; Solinas E; Reverberi C; Menozzi A; Vignali L; Malagò R; Midiri M; Mollet NR; Cervellin G; Ardissino D
    Radiol Med; 2008 Mar; 113(2):163-80. PubMed ID: 18386119
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Diagnostic accuracy of 64-slice computed tomography coronary angiography in patients with low-to-intermediate risk.
    Cademartiri F; Maffei E; Palumbo A; Malagò R; Alberghina F; Aldrovandi A; Brambilla V; Runza G; La Grutta L; Menozzi A; Vignali L; Casolo G; Midiri M; Mollet NR
    Radiol Med; 2007 Oct; 112(7):969-81. PubMed ID: 17952682
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation of heavily calcified vessels with coronary CT angiography: comparison of iterative and filtered back projection image reconstruction.
    Renker M; Nance JW; Schoepf UJ; O'Brien TX; Zwerner PL; Meyer M; Kerl JM; Bauer RW; Fink C; Vogl TJ; Henzler T
    Radiology; 2011 Aug; 260(2):390-9. PubMed ID: 21693660
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Significant coronary artery stenosis: comparison on per-patient and per-vessel or per-segment basis at 64-section CT angiography.
    Herzog C; Zwerner PL; Doll JR; Nielsen CD; Nguyen SA; Savino G; Vogl TJ; Costello P; Schoepf UJ
    Radiology; 2007 Jul; 244(1):112-20. PubMed ID: 17581898
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.