BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

555 related articles for article (PubMed ID: 20018280)

  • 1. A retrograde-viewing device improves detection of adenomas in the colon: a prospective efficacy evaluation (with videos).
    Waye JD; Heigh RI; Fleischer DE; Leighton JA; Gurudu S; Aldrich LB; Li J; Ramrakhiani S; Edmundowicz SA; Early DS; Jonnalagadda S; Bresalier RS; Kessler WR; Rex DK
    Gastrointest Endosc; 2010 Mar; 71(3):551-6. PubMed ID: 20018280
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Impact of experience with a retrograde-viewing device on adenoma detection rates and withdrawal times during colonoscopy: the Third Eye Retroscope study group.
    DeMarco DC; Odstrcil E; Lara LF; Bass D; Herdman C; Kinney T; Gupta K; Wolf L; Dewar T; Deas TM; Mehta MK; Anwer MB; Pellish R; Hamilton JK; Polter D; Reddy KG; Hanan I
    Gastrointest Endosc; 2010 Mar; 71(3):542-50. PubMed ID: 20189513
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effect of a retrograde-viewing device on adenoma detection rate during colonoscopy: the TERRACE study.
    Leufkens AM; DeMarco DC; Rastogi A; Akerman PA; Azzouzi K; Rothstein RI; Vleggaar FP; Repici A; Rando G; Okolo PI; Dewit O; Ignjatovic A; Odstrcil E; East J; Deprez PH; Saunders BP; Kalloo AN; Creel B; Singh V; Lennon AM; Siersema PD;
    Gastrointest Endosc; 2011 Mar; 73(3):480-9. PubMed ID: 21067735
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A novel retrograde-viewing auxiliary imaging device (Third Eye Retroscope) improves the detection of simulated polyps in anatomic models of the colon.
    Triadafilopoulos G; Watts HD; Higgins J; Van Dam J
    Gastrointest Endosc; 2007 Jan; 65(1):139-44. PubMed ID: 17185094
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of standard forward-viewing mode versus ultrawide-viewing mode of a novel colonoscopy platform: a prospective, multicenter study in the detection of simulated polyps in an in vitro colon model (with video).
    Gralnek IM; Carr-Locke DL; Segol O; Halpern Z; Siersema PD; Sloyer A; Fenster J; Lewis BS; Santo E; Suissa A; Segev M
    Gastrointest Endosc; 2013 Mar; 77(3):472-9. PubMed ID: 23410700
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Dynamic patient position changes during colonoscope withdrawal increase adenoma detection: a randomized, crossover trial.
    East JE; Bassett P; Arebi N; Thomas-Gibson S; Guenther T; Saunders BP
    Gastrointest Endosc; 2011 Mar; 73(3):456-63. PubMed ID: 20950801
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Advanced technology for the improvement of adenoma and polyp detection during colonoscopy.
    Moriyama T; Uraoka T; Esaki M; Matsumoto T
    Dig Endosc; 2015 Apr; 27 Suppl 1():40-4. PubMed ID: 25556542
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A pilot study to assess the safety and efficacy of the Third Eye retrograde auxiliary imaging system during colonoscopy.
    Triadafilopoulos G; Li J
    Endoscopy; 2008 Jun; 40(6):478-82. PubMed ID: 18543136
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Factors influencing the miss rate of polyps in a back-to-back colonoscopy study.
    Leufkens AM; van Oijen MG; Vleggaar FP; Siersema PD
    Endoscopy; 2012 May; 44(5):470-5. PubMed ID: 22441756
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A novel balloon colonoscope detects significantly more simulated polyps than a standard colonoscope in a colon model.
    Hasan N; Gross SA; Gralnek IM; Pochapin M; Kiesslich R; Halpern Z
    Gastrointest Endosc; 2014 Dec; 80(6):1135-40. PubMed ID: 24929483
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Expanding the view of a standard colonoscope with the Third Eye Panoramic cap.
    Rubin M; Lurie L; Bose K; Kim SH
    World J Gastroenterol; 2015 Oct; 21(37):10683-7. PubMed ID: 26457029
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Emerging technological advancements in colonoscopy: Third Eye® Retroscope® and Third Eye® Panoramic(TM) , Fuse® Full Spectrum Endoscopy® colonoscopy platform, Extra-Wide-Angle-View colonoscope, and NaviAid(TM) G-EYE(TM) balloon colonoscope.
    Gralnek IM
    Dig Endosc; 2015 Jan; 27(2):223-31. PubMed ID: 25251748
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Short turn radius colonoscope in an anatomical model: retroflexed withdrawal and detection of hidden polyps.
    McGill SK; Kothari S; Friedland S; Chen A; Park WG; Banerjee S
    World J Gastroenterol; 2015 Jan; 21(2):593-9. PubMed ID: 25593483
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Miss rate of right-sided colon examination during colonoscopy defined by retroflexion: an observational study.
    Hewett DG; Rex DK
    Gastrointest Endosc; 2011 Aug; 74(2):246-52. PubMed ID: 21679946
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of adenoma detection and miss rates between a novel balloon colonoscope and standard colonoscopy: a randomized tandem study.
    Halpern Z; Gross SA; Gralnek IM; Shpak B; Pochapin M; Hoffman A; Mizrahi M; Rochberger YS; Moshkowitz M; Santo E; Melhem A; Grinshpon R; Pfefer J; Kiesslich R
    Endoscopy; 2015 Mar; 47(3):238-44. PubMed ID: 25704662
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Cecal insertion and withdrawal times with wide-angle versus standard colonoscopes: a randomized controlled trial.
    Fatima H; Rex DK; Rothstein R; Rahmani E; Nehme O; Dewitt J; Helper D; Toor A; Bensen S
    Clin Gastroenterol Hepatol; 2008 Jan; 6(1):109-14. PubMed ID: 18065277
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Feasibility of a novel colonoscope with extra-wide angle of view: a clinical study.
    Uraoka T; Tanaka S; Oka S; Matsuda T; Saito Y; Moriyama T; Higashi R; Matsumoto T
    Endoscopy; 2015 May; 47(5):444-8. PubMed ID: 25412088
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A novel extra-wide-angle-view colonoscope: a simulated pilot study using anatomic colorectal models.
    Uraoka T; Tanaka S; Matsumoto T; Matsuda T; Oka S; Moriyama T; Higashi R; Saito Y
    Gastrointest Endosc; 2013 Mar; 77(3):480-3. PubMed ID: 23199903
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Retrograde-viewing device improves adenoma detection rate in colonoscopies for surveillance and diagnostic workup.
    Siersema PD; Rastogi A; Leufkens AM; Akerman PA; Azzouzi K; Rothstein RI; Vleggaar FP; Repici A; Rando G; Okolo PI; Dewit O; Ignjatovic A; Odstrcil E; East J; Deprez PH; Saunders BP; Kalloo AN; Creel B; Singh V; Lennon AM; DeMarco DC
    World J Gastroenterol; 2012 Jul; 18(26):3400-8. PubMed ID: 22807609
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A randomized controlled trial assessing the effect of prescribed patient position changes during colonoscope withdrawal on adenoma detection.
    Ou G; Kim E; Lakzadeh P; Tong J; Enns R; Ramji A; Whittaker S; Ko HH; Bressler B; Halparin L; Lam E; Amar J; Telford J
    Gastrointest Endosc; 2014 Aug; 80(2):277-83. PubMed ID: 24629419
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 28.