These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

226 related articles for article (PubMed ID: 20018287)

  • 1. The effect of positioning on the biomechanical performance of soft shell hip protectors.
    Choi WJ; Hoffer JA; Robinovitch SN
    J Biomech; 2010 Mar; 43(5):818-25. PubMed ID: 20018287
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The force attenuation provided by hip protectors depends on impact velocity, pelvic size, and soft tissue stiffness.
    Laing AC; Robinovitch SN
    J Biomech Eng; 2008 Dec; 130(6):061005. PubMed ID: 19045534
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Anatomical hip model for the mechanical testing of hip protectors.
    Derler S; Spierings AB; Schmitt KU
    Med Eng Phys; 2005 Jul; 27(6):475-85. PubMed ID: 15990064
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Energy-shunting external hip protector attenuates the peak femoral impact force below the theoretical fracture threshold: an in vitro biomechanical study under falling conditions of the elderly.
    Parkkari J; Kannus P; Heikkilä J; Poutala J; Sievänen H; Vuori I
    J Bone Miner Res; 1995 Oct; 10(10):1437-42. PubMed ID: 8686498
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Biomechanical comparison of hard and soft hip protectors, and the influence of soft tissue.
    van Schoor NM; van der Veen AJ; Schaap LA; Smit TH; Lips P
    Bone; 2006 Aug; 39(2):401-7. PubMed ID: 16546458
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effect of soft shell hip protectors on pressure distribution to the hip during sideways falls.
    Laing AC; Robinovitch SN
    Osteoporos Int; 2008 Jul; 19(7):1067-75. PubMed ID: 18338098
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effect of hip protectors, falling angle and body mass index on pressure distribution over the hip during simulated falls.
    Choi WJ; Hoffer JA; Robinovitch SN
    Clin Biomech (Bristol); 2010 Jan; 25(1):63-9. PubMed ID: 19766363
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of force attenuation properties of four different hip protectors under simulated falling conditions in the elderly: an in vitro biomechanical study.
    Kannus P; Parkkari J; Poutala J
    Bone; 1999 Aug; 25(2):229-35. PubMed ID: 10456390
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Prevention with hip protectors. Biomechanical aspects in falls and hip fractures].
    Lauritzen JB
    Nord Med; 1996 Dec; 111(10):340-3. PubMed ID: 8992465
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Prevention of hip fracture with hip protectors.
    Kannus P; Parkkari J
    Age Ageing; 2006 Sep; 35 Suppl 2():ii51-ii54. PubMed ID: 16926206
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Hip protectors: a pilot study of older people in Taiwan.
    Huang HC; Lee CH; Wu SL
    J Clin Nurs; 2006 Apr; 15(4):436-43. PubMed ID: 16553757
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Contribution of trochanteric soft tissues to fall force estimates, the factor of risk, and prediction of hip fracture risk.
    Bouxsein ML; Szulc P; Munoz F; Thrall E; Sornay-Rendu E; Delmas PD
    J Bone Miner Res; 2007 Jun; 22(6):825-31. PubMed ID: 17352651
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Development of a new design of hip protectors using finite element analysis and mechanical tests.
    Schmid Daners M; Wullschleger L; Derler S; Schmitt KU
    Med Eng Phys; 2008 Nov; 30(9):1186-92. PubMed ID: 18424166
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Are hip protectors correctly positioned in use?
    Minns RJ; Marsh AM; Chuck A; Todd J
    Age Ageing; 2007 Mar; 36(2):140-4. PubMed ID: 17272302
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of impact force attenuation by various combinations of hip protector and flooring material using a simplified fall-impact simulation device.
    Li N; Tsushima E; Tsushima H
    J Biomech; 2013 Apr; 46(6):1140-6. PubMed ID: 23411114
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Assessment of hip protectors and corresponding hip fracture risk using stress calculation in the femoral neck.
    Spierings AB; Derler S
    Med Eng Phys; 2006 Jul; 28(6):550-9. PubMed ID: 16275044
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The effect of type of hip protector and resident characteristics on adherence to use of hip protectors in nursing and residential homes--an exploratory study.
    O'Halloran PD; Murray LJ; Cran GW; Dunlop L; Kernohan G; Beringer TR
    Int J Nurs Stud; 2005 May; 42(4):387-97. PubMed ID: 15847901
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Mechanical testing of different hip protectors according to a European Standard.
    Holzer LA; von Skrbensky G; Holzer G
    Injury; 2009 Nov; 40(11):1172-5. PubMed ID: 19524913
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [External hip protectors against hip fractures. A randomized study in a nursing home].
    Lauritzen JB; Petersen MM; Lund B
    Ugeskr Laeger; 1993 May; 155(20):1523-6. PubMed ID: 8316982
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Hip protectors: recommendations for biomechanical testing--an international consensus statement (part I).
    Robinovitch SN; Evans SL; Minns J; Laing AC; Kannus P; Cripton PA; Derler S; Birge SJ; Plant D; Cameron ID; Kiel DP; Howland J; Khan K; Lauritzen JB
    Osteoporos Int; 2009 Dec; 20(12):1977-88. PubMed ID: 19806286
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.