These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

209 related articles for article (PubMed ID: 20018435)

  • 1. Opening of the blood-brain barrier by low-frequency (28-kHz) ultrasound: a novel pinhole-assisted mechanical scanning device.
    Liu HL; Pan CH; Ting CY; Hsiao MJ
    Ultrasound Med Biol; 2010 Feb; 36(2):325-35. PubMed ID: 20018435
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Focused ultrasound-mediated noninvasive blood-brain barrier modulation: preclinical examination of efficacy and safety in various sonication parameters.
    Shin J; Kong C; Cho JS; Lee J; Koh CS; Yoon MS; Na YC; Chang WS; Chang JW
    Neurosurg Focus; 2018 Feb; 44(2):E15. PubMed ID: 29385915
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Magnetic resonance imaging enhanced by superparamagnetic iron oxide particles: usefulness for distinguishing between focused ultrasound-induced blood-brain barrier disruption and brain hemorrhage.
    Liu HL; Hsu PH; Chu PC; Wai YY; Chen JC; Shen CR; Yen TC; Wang JJ
    J Magn Reson Imaging; 2009 Jan; 29(1):31-8. PubMed ID: 19097103
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Focused Ultrasound-Induced Blood-Brain Barrier Opening: Association with Mechanical Index and Cavitation Index Analyzed by Dynamic Contrast-Enhanced Magnetic-Resonance Imaging.
    Chu PC; Chai WY; Tsai CH; Kang ST; Yeh CK; Liu HL
    Sci Rep; 2016 Sep; 6():33264. PubMed ID: 27630037
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Real-time monitoring of focused ultrasound blood-brain barrier opening via subharmonic acoustic emission detection: implementation of confocal dual-frequency piezoelectric transducers.
    Tsai CH; Zhang JW; Liao YY; Liu HL
    Phys Med Biol; 2016 Apr; 61(7):2926-46. PubMed ID: 26988240
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Drug-loaded bubbles with matched focused ultrasound excitation for concurrent blood-brain barrier opening and brain-tumor drug delivery.
    Fan CH; Ting CY; Chang YC; Wei KC; Liu HL; Yeh CK
    Acta Biomater; 2015 Mar; 15():89-101. PubMed ID: 25575854
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Opening of the blood-brain barrier with an unfocused ultrasound device in rabbits.
    Beccaria K; Canney M; Goldwirt L; Fernandez C; Adam C; Piquet J; Autret G; Clément O; Lafon C; Chapelon JY; Carpentier A
    J Neurosurg; 2013 Oct; 119(4):887-98. PubMed ID: 23790118
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Characterization of Different Microbubbles in Assisting Focused Ultrasound-Induced Blood-Brain Barrier Opening.
    Wu SK; Chu PC; Chai WY; Kang ST; Tsai CH; Fan CH; Yeh CK; Liu HL
    Sci Rep; 2017 Apr; 7():46689. PubMed ID: 28425493
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Safe long-term repeated disruption of the blood-brain barrier using an implantable ultrasound device: a multiparametric study in a primate model.
    Horodyckid C; Canney M; Vignot A; Boisgard R; Drier A; Huberfeld G; François C; Prigent A; Santin MD; Adam C; Willer JC; Lafon C; Chapelon JY; Carpentier A
    J Neurosurg; 2017 Apr; 126(4):1351-1361. PubMed ID: 27285538
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Hemorrhage detection during focused-ultrasound induced blood-brain-barrier opening by using susceptibility-weighted magnetic resonance imaging.
    Liu HL; Wai YY; Chen WS; Chen JC; Hsu PH; Wu XY; Huang WC; Yen TC; Wang JJ
    Ultrasound Med Biol; 2008 Apr; 34(4):598-606. PubMed ID: 18313204
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Ultrasound, microbubbles and the blood-brain barrier.
    Meairs S; Alonso A
    Prog Biophys Mol Biol; 2007; 93(1-3):354-62. PubMed ID: 16959303
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Establishing sheep as an experimental species to validate ultrasound-mediated blood-brain barrier opening for potential therapeutic interventions.
    Pelekanos M; Leinenga G; Odabaee M; Odabaee M; Saifzadeh S; Steck R; Götz J
    Theranostics; 2018; 8(9):2583-2602. PubMed ID: 29721100
    [No Abstract]   [Full Text] [Related]  

  • 13. Chirp- and random-based coded ultrasonic excitation for localized blood-brain barrier opening.
    Kamimura HA; Wang S; Wu SY; Karakatsani ME; Acosta C; Carneiro AA; Konofagou EE
    Phys Med Biol; 2015 Oct; 60(19):7695-712. PubMed ID: 26394091
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Histologic evaluation of activation of acute inflammatory response in a mouse model following ultrasound-mediated blood-brain barrier using different acoustic pressures and microbubble doses.
    Pascal A; Li N; Lechtenberg KJ; Rosenberg J; Airan RD; James ML; Bouley DM; Pauly KB
    Nanotheranostics; 2020; 4(4):210-223. PubMed ID: 32802731
    [No Abstract]   [Full Text] [Related]  

  • 15. Acoustic cavitation-based monitoring of the reversibility and permeability of ultrasound-induced blood-brain barrier opening.
    Sun T; Samiotaki G; Wang S; Acosta C; Chen CC; Konofagou EE
    Phys Med Biol; 2015 Dec; 60(23):9079-94. PubMed ID: 26562661
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Blood-brain barrier disruption with focused ultrasound enhances delivery of chemotherapeutic drugs for glioblastoma treatment.
    Liu HL; Hua MY; Chen PY; Chu PC; Pan CH; Yang HW; Huang CY; Wang JJ; Yen TC; Wei KC
    Radiology; 2010 May; 255(2):415-25. PubMed ID: 20413754
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Blood-Brain Barrier Opening with MRI-guided Focused Ultrasound Elicits Meningeal Venous Permeability in Humans with Early Alzheimer Disease.
    Mehta RI; Carpenter JS; Mehta RI; Haut MW; Ranjan M; Najib U; Lockman P; Wang P; D'haese PF; Rezai AR
    Radiology; 2021 Mar; 298(3):654-662. PubMed ID: 33399511
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Noninvasive hippocampal blood-brain barrier opening in Alzheimer's disease with focused ultrasound.
    Rezai AR; Ranjan M; D'Haese PF; Haut MW; Carpenter J; Najib U; Mehta RI; Chazen JL; Zibly Z; Yates JR; Hodder SL; Kaplitt M
    Proc Natl Acad Sci U S A; 2020 Apr; 117(17):9180-9182. PubMed ID: 32284421
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The role of caveolin-1 in blood-brain barrier disruption induced by focused ultrasound combined with microbubbles.
    Deng J; Huang Q; Wang F; Liu Y; Wang Z; Wang Z; Zhang Q; Lei B; Cheng Y
    J Mol Neurosci; 2012 Mar; 46(3):677-87. PubMed ID: 21861133
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Feasibility of ultrasound-induced blood-brain barrier disruption with a single-element transducer under three different frequencies in two non-human primates in vivo: Case report.
    Zhou H; Liu Y; Long X; Qiao Y; Lee J; Peng H; Liu X; Zou C; Zheng H
    J Neurosci Methods; 2022 Jan; 365():109383. PubMed ID: 34634283
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.