These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
44. Association of third body embedment with rim damage in retrieved acetabular liners. Lundberg HJ; Liu SS; Callaghan JJ; Pedersen DR; O'Rourke MR; Goetz DD; Vittetoe DA; Clohisy JC; Brown TD Clin Orthop Relat Res; 2007 Dec; 465():133-9. PubMed ID: 18090471 [TBL] [Abstract][Full Text] [Related]
45. CORR Insights(®): Backside Wear Is Not Dependent on the Acetabular Socket Design in Crosslinked Polyethylene Liners. Nich C Clin Orthop Relat Res; 2016 Feb; 474(2):383-5. PubMed ID: 26260395 [No Abstract] [Full Text] [Related]
46. Polyethylene wear and osteolysis with a new modular titanium acetabular component: results at 7 to 13 years. Lachiewicz PF; Hubbard JB; Soileau ES J Arthroplasty; 2008 Oct; 23(7):971-6. PubMed ID: 18534508 [TBL] [Abstract][Full Text] [Related]
47. In vitro quantification of wear in tibial inserts using microcomputed tomography. Teeter MG; Naudie DD; McErlain DD; Brandt JM; Yuan X; Macdonald SJ; Holdsworth DW Clin Orthop Relat Res; 2011 Jan; 469(1):107-12. PubMed ID: 20676810 [TBL] [Abstract][Full Text] [Related]
48. Technique to quantify subsurface cracks in retrieved polyethylene components using micro-CT. Teeter MG; Yuan X; Naudie DD; Holdsworth DW J Long Term Eff Med Implants; 2010; 20(1):27-34. PubMed ID: 21284585 [TBL] [Abstract][Full Text] [Related]
49. Quantitative evaluation of retrieved reverse total shoulder arthroplasty liner surface deviation and volumetric wear. Kurdziel MD; Newton MD; Hartner S; Baker KC; Wiater JM J Orthop Res; 2018 Jul; 36(7):2007-2014. PubMed ID: 29314184 [TBL] [Abstract][Full Text] [Related]
50. Wear and surface cracking in early retrieved highly cross-linked polyethylene acetabular liners. Bradford L; Baker DA; Graham J; Chawan A; Ries MD; Pruitt LA J Bone Joint Surg Am; 2004 Jun; 86(6):1271-82. PubMed ID: 15173302 [TBL] [Abstract][Full Text] [Related]
51. Wear rates of retentive versus nonretentive reverse total shoulder arthroplasty liners in an in vitro wear simulation. Carpenter S; Pinkas D; Newton MD; Kurdziel MD; Baker KC; Wiater JM J Shoulder Elbow Surg; 2015 Sep; 24(9):1372-9. PubMed ID: 25842031 [TBL] [Abstract][Full Text] [Related]
52. Regional measurements of surface deviation volume in worn polyethylene joint replacement components. Teeter MG; Milner JS; Au JL; Lorusso D; Naudie DD; Holdsworth DW J Long Term Eff Med Implants; 2010; 20(1):49-56. PubMed ID: 21284588 [TBL] [Abstract][Full Text] [Related]
53. Mechanical wear and oxidative degradation analysis of retrieved ultra high molecular weight polyethylene acetabular cups. Choudhury D; Ranuša M; Fleming RA; Vrbka M; Křupka I; Teeter MG; Goss J; Zou M J Mech Behav Biomed Mater; 2018 Mar; 79():314-323. PubMed ID: 29353775 [TBL] [Abstract][Full Text] [Related]