These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

127 related articles for article (PubMed ID: 20022448)

  • 41. Design factors influencing performance of constrained acetabular liners: finite element characterization.
    Bouchard SM; Stewart KJ; Pedersen DR; Callaghan JJ; Brown TD
    J Biomech; 2006; 39(5):885-93. PubMed ID: 16488227
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Short-term wear of Japanese highly cross-linked polyethylene in cementless THA.
    Miyanishi K; Hara T; Kaminomachi S; Maekawa M; Iwamoto M; Torisu T
    Arch Orthop Trauma Surg; 2008 Sep; 128(9):995-1000. PubMed ID: 18175133
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Backside wear in acetabular hip joint replacement.
    Braun S; Sonntag R; Schroeder S; Mueller U; Jaeger S; Gotterbarm T; Kretzer JP
    Acta Biomater; 2019 Jan; 83():467-476. PubMed ID: 30408561
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Association of third body embedment with rim damage in retrieved acetabular liners.
    Lundberg HJ; Liu SS; Callaghan JJ; Pedersen DR; O'Rourke MR; Goetz DD; Vittetoe DA; Clohisy JC; Brown TD
    Clin Orthop Relat Res; 2007 Dec; 465():133-9. PubMed ID: 18090471
    [TBL] [Abstract][Full Text] [Related]  

  • 45. CORR Insights(®): Backside Wear Is Not Dependent on the Acetabular Socket Design in Crosslinked Polyethylene Liners.
    Nich C
    Clin Orthop Relat Res; 2016 Feb; 474(2):383-5. PubMed ID: 26260395
    [No Abstract]   [Full Text] [Related]  

  • 46. Polyethylene wear and osteolysis with a new modular titanium acetabular component: results at 7 to 13 years.
    Lachiewicz PF; Hubbard JB; Soileau ES
    J Arthroplasty; 2008 Oct; 23(7):971-6. PubMed ID: 18534508
    [TBL] [Abstract][Full Text] [Related]  

  • 47. In vitro quantification of wear in tibial inserts using microcomputed tomography.
    Teeter MG; Naudie DD; McErlain DD; Brandt JM; Yuan X; Macdonald SJ; Holdsworth DW
    Clin Orthop Relat Res; 2011 Jan; 469(1):107-12. PubMed ID: 20676810
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Technique to quantify subsurface cracks in retrieved polyethylene components using micro-CT.
    Teeter MG; Yuan X; Naudie DD; Holdsworth DW
    J Long Term Eff Med Implants; 2010; 20(1):27-34. PubMed ID: 21284585
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Quantitative evaluation of retrieved reverse total shoulder arthroplasty liner surface deviation and volumetric wear.
    Kurdziel MD; Newton MD; Hartner S; Baker KC; Wiater JM
    J Orthop Res; 2018 Jul; 36(7):2007-2014. PubMed ID: 29314184
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Wear and surface cracking in early retrieved highly cross-linked polyethylene acetabular liners.
    Bradford L; Baker DA; Graham J; Chawan A; Ries MD; Pruitt LA
    J Bone Joint Surg Am; 2004 Jun; 86(6):1271-82. PubMed ID: 15173302
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Wear rates of retentive versus nonretentive reverse total shoulder arthroplasty liners in an in vitro wear simulation.
    Carpenter S; Pinkas D; Newton MD; Kurdziel MD; Baker KC; Wiater JM
    J Shoulder Elbow Surg; 2015 Sep; 24(9):1372-9. PubMed ID: 25842031
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Regional measurements of surface deviation volume in worn polyethylene joint replacement components.
    Teeter MG; Milner JS; Au JL; Lorusso D; Naudie DD; Holdsworth DW
    J Long Term Eff Med Implants; 2010; 20(1):49-56. PubMed ID: 21284588
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Mechanical wear and oxidative degradation analysis of retrieved ultra high molecular weight polyethylene acetabular cups.
    Choudhury D; Ranuša M; Fleming RA; Vrbka M; Křupka I; Teeter MG; Goss J; Zou M
    J Mech Behav Biomed Mater; 2018 Mar; 79():314-323. PubMed ID: 29353775
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Can microcomputed tomography measure retrieved polyethylene wear? Comparing fixed-bearing and rotating-platform knees.
    Engh CA; Zimmerman RL; Hopper RH; Engh GA
    Clin Orthop Relat Res; 2013 Jan; 471(1):86-93. PubMed ID: 22879092
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Retrieved highly crosslinked UHMWPE acetabular liners have similar wear damage as conventional UHMWPE.
    Schroder DT; Kelly NH; Wright TM; Parks ML
    Clin Orthop Relat Res; 2011 Feb; 469(2):387-94. PubMed ID: 20844998
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Deformation and Recovery of Thin Metal-Backed, Two-Piece Polyethylene Acetabular Resurfacing Components.
    Pritchett J
    J Long Term Eff Med Implants; 2019; 29(1):59-69. PubMed ID: 31679203
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Surface extraction can provide a reference for micro-CT analysis of retrieved total knee implants.
    Teeter MG; Milner JS; Naudie DD; MacDonald SJ
    Knee; 2014 Aug; 21(4):801-5. PubMed ID: 24853191
    [TBL] [Abstract][Full Text] [Related]  

  • 58. [Dual articulation retentive acetabular liners and wear: surface analysis of 40 retrieved polyethylene implants].
    Adam P; Farizon F; Fessy MH
    Rev Chir Orthop Reparatrice Appar Mot; 2005 Nov; 91(7):627-36. PubMed ID: 16327667
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Fracture of a cross-linked polyethylene liner: a multifactorial issue.
    Blumenfeld TJ; McKellop HA; Schmalzried TP; Billi F
    J Arthroplasty; 2011 Jun; 26(4):666.e5-8. PubMed ID: 20851563
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Determination of reference geometry for polyethylene tibial insert wear analysis.
    Teeter MG; Naudie DD; Milner JS; Holdsworth DW
    J Arthroplasty; 2011 Apr; 26(3):497-503. PubMed ID: 20347254
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.