These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

185 related articles for article (PubMed ID: 20024041)

  • 1. An automated, pre-programmed, multiplexed, hydraulic microvalve.
    Kim J; Chen D; Bau HH
    Lab Chip; 2009 Dec; 9(24):3594-8. PubMed ID: 20024041
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Manufacturable plastic microfluidic valves using thermal actuation.
    Pitchaimani K; Sapp BC; Winter A; Gispanski A; Nishida T; Hugh Fan Z
    Lab Chip; 2009 Nov; 9(21):3082-7. PubMed ID: 19823723
    [TBL] [Abstract][Full Text] [Related]  

  • 3. PMMA/PDMS valves and pumps for disposable microfluidics.
    Zhang W; Lin S; Wang C; Hu J; Li C; Zhuang Z; Zhou Y; Mathies RA; Yang CJ
    Lab Chip; 2009 Nov; 9(21):3088-94. PubMed ID: 19823724
    [TBL] [Abstract][Full Text] [Related]  

  • 4. An electromagnetic microvalve for pneumatic control of microfluidic systems.
    Liu X; Li S
    J Lab Autom; 2014 Oct; 19(5):444-53. PubMed ID: 24742860
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Self-actuated, thermo-responsive hydrogel valves for lab on a chip.
    Wang J; Chen Z; Mauk M; Hong KS; Li M; Yang S; Bau HH
    Biomed Microdevices; 2005 Dec; 7(4):313-22. PubMed ID: 16404509
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Development and multiplexed control of latching pneumatic valves using microfluidic logical structures.
    Grover WH; Ivester RH; Jensen EC; Mathies RA
    Lab Chip; 2006 May; 6(5):623-31. PubMed ID: 16652177
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A micro circulating PCR chip using a suction-type membrane for fluidic transport.
    Chien LJ; Wang JH; Hsieh TM; Chen PH; Chen PJ; Lee DS; Luo CH; Lee GB
    Biomed Microdevices; 2009 Apr; 11(2):359-67. PubMed ID: 18975094
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Lab-on-a-chip for multiplexed biosensing of residual antibiotics in milk.
    Suárez G; Jin YH; Auerswald J; Berchtold S; Knapp HF; Diserens JM; Leterrier Y; Månson JA; Voirin G
    Lab Chip; 2009 Jun; 9(11):1625-30. PubMed ID: 19458872
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Designed pneumatic valve actuators for controlled droplet breakup and generation.
    Choi JH; Lee SK; Lim JM; Yang SM; Yi GR
    Lab Chip; 2010 Feb; 10(4):456-61. PubMed ID: 20126685
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A microfabricated CE chip for DNA pre-concentration and separation utilizing a normally closed valve.
    Kuo CH; Wang JH; Lee GB
    Electrophoresis; 2009 Sep; 30(18):3228-35. PubMed ID: 19722201
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Temperature distribution effects on micro-CFPCR performance.
    Chen PC; Nikitopoulos DE; Soper SA; Murphy MC
    Biomed Microdevices; 2008 Apr; 10(2):141-52. PubMed ID: 17896180
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Microfluidic valve with cored glass microneedle for microinjection.
    Lee S; Jeong W; Beebe DJ
    Lab Chip; 2003 Aug; 3(3):164-7. PubMed ID: 15100768
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Thermally-actuated, phase change flow control for microfluidic systems.
    Chen Z; Wang J; Qian S; Bau HH
    Lab Chip; 2005 Nov; 5(11):1277-85. PubMed ID: 16234952
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Electrically controlled microvalves to integrate microchip polymerase chain reaction and capillary electrophoresis.
    Kaigala GV; Hoang VN; Backhouse CJ
    Lab Chip; 2008 Jul; 8(7):1071-8. PubMed ID: 18584081
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Ionogel-based light-actuated valves for controlling liquid flow in micro-fluidic manifolds.
    Benito-Lopez F; Byrne R; Răduţă AM; Vrana NE; McGuinness G; Diamond D
    Lab Chip; 2010 Jan; 10(2):195-201. PubMed ID: 20066247
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A disposable on-chip microvalve and pump for programmable microfluidics.
    Im SB; Uddin MJ; Jin GJ; Shim JS
    Lab Chip; 2018 May; 18(9):1310-1319. PubMed ID: 29619470
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Automated electric valve for electrokinetic separation in a networked microfluidic chip.
    Cui H; Huang Z; Dutta P; Ivory CF
    Anal Chem; 2007 Feb; 79(4):1456-65. PubMed ID: 17297944
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Automated chip-based device for simple and fast nucleic acid amplification.
    Münchow G; Dadic D; Doffing F; Hardt S; Drese KS
    Expert Rev Mol Diagn; 2005 Jul; 5(4):613-20. PubMed ID: 16013978
    [TBL] [Abstract][Full Text] [Related]  

  • 19. PCR microfluidic devices for DNA amplification.
    Zhang C; Xu J; Ma W; Zheng W
    Biotechnol Adv; 2006; 24(3):243-84. PubMed ID: 16326063
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A self-contained fully-enclosed microfluidic cartridge for lab on a chip.
    Yobas L; Cheow LF; Tang KC; Yong SE; Ong EK; Wong L; Teo WC; Ji H; Rafeah S; Yu C
    Biomed Microdevices; 2009 Dec; 11(6):1279-88. PubMed ID: 19757073
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.