BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

176 related articles for article (PubMed ID: 20033789)

  • 21. Multilayer conformal applicator for microwave heating and brachytherapy treatment of superficial tissue disease.
    Juang T; Stauffer PR; Neuman DG; Schlorff JL
    Int J Hyperthermia; 2006 Nov; 22(7):527-44. PubMed ID: 17079212
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Broadband microwave spiral applicator (105-125 MHz) for
    Walter J; Hader M; Sengedorj A; Fietkau R; Frey B; Gaipl US
    Int J Hyperthermia; 2023; 40(1):2265590. PubMed ID: 37813393
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Theoretical and experimental analysis of air cooling for intracavitary microwave hyperthermia applicators.
    Yeh MM; Trembly BS; Douple EB; Ryan TP; Hoopes PJ; Jonsson E; Heaney JA
    IEEE Trans Biomed Eng; 1994 Sep; 41(9):874-82. PubMed ID: 7959814
    [TBL] [Abstract][Full Text] [Related]  

  • 24. SAR characteristics of three types of Contact Flexible Microstrip Applicators for superficial hyperthermia.
    Lamaitre G; Van Dijk JD; Gelvich EA; Wiersma J; Schneider CJ
    Int J Hyperthermia; 1996; 12(2):255-69. PubMed ID: 8926393
    [TBL] [Abstract][Full Text] [Related]  

  • 25. A variable microwave array attenuator for use with single-element waveguide applicators.
    Sherar MD; Clark H; Cooper B; Kumaradas J; Liu FF
    Int J Hyperthermia; 1994; 10(5):723-31. PubMed ID: 7806927
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Improved applicator-patient coupling in microwave-induced hyperthermia.
    Nussbaum GH; Goodman RA; Bruce AA
    Med Phys; 1983; 10(6):897-8. PubMed ID: 6656702
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [A simple coupled instrument for hyperthermia].
    Wang W
    Zhongguo Yi Liao Qi Xie Za Zhi; 2001 Jul; 25(4):239. PubMed ID: 12583228
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Equilibrium temperature distributions in uniform phantoms for superficial microwave applicators: implications for temperature-based standards of applicator adequacy.
    Myerson RJ; Emami BN; Perez CA; Straube W; Leybovich L; Von Gerichten D
    Int J Hyperthermia; 1992; 8(1):11-21. PubMed ID: 1545156
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Simultaneous localized 915 MHz external and interstitial microwave hyperthermia to heat tumors greater than 3 cm in depth.
    Mittal BB; Sathiaseelan V; Kies MS
    Int J Radiat Oncol Biol Phys; 1990 Sep; 19(3):669-75. PubMed ID: 2211214
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Design and thermometry of an intracavitary microwave applicator suitable for treatment of some vaginal and rectal cancers.
    Li DJ; Luk KH; Jiang HB; Chou CK; Hwang GZ
    Int J Radiat Oncol Biol Phys; 1984 Nov; 10(11):2155-62. PubMed ID: 6490441
    [TBL] [Abstract][Full Text] [Related]  

  • 31. A printed Yagi-Uda antenna for application in magnetic resonance thermometry guided microwave hyperthermia applicators.
    Paulides MM; Mestrom RM; Salim G; Adela BB; Numan WC; Drizdal T; Yeo DT; Smolders AB
    Phys Med Biol; 2017 Mar; 62(5):1831-1847. PubMed ID: 28052042
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Hyperthermic treatment of intraocular tumors.
    Finger PT; Packer S; Svitra PP; Paglione RW; Chess J; Albert DM
    Arch Ophthalmol; 1984 Oct; 102(10):1477-81. PubMed ID: 6487114
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Phantom evaluation of heating of superficial tissues located above interstitial microwave antennas.
    Leybovich LB; Devanna WG; Gray AC; Kurup RG; Fan CJ
    Int J Radiat Oncol Biol Phys; 1993 Sep; 27(1):101-8. PubMed ID: 8365930
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Conformal hyperthermia of superficial tumor with left-handed metamaterial lens applicator.
    Tao Y; Wang G
    IEEE Trans Biomed Eng; 2012 Dec; 59(12):3525-30. PubMed ID: 23033426
    [TBL] [Abstract][Full Text] [Related]  

  • 35. [The characterization of semirigid coaxial antennae for interstitial and endocavitary microwave hyperthermia].
    Erb J; Klautke G; Seegenschmiedt HM; Engelbrecht R; Schaller G; Sauer R
    Strahlenther Onkol; 1994 Nov; 170(11):654-64. PubMed ID: 7974181
    [TBL] [Abstract][Full Text] [Related]  

  • 36. [Research on the hyperthermia-therapy performances of invasive microwave antennas].
    Yang GS; Liu YH; Wang JQ
    Zhongguo Yi Liao Qi Xie Za Zhi; 2002 Mar; 26(3):170-1, 217. PubMed ID: 16104297
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Non-invasive microwave multifrequency radiometry used in microwave hyperthermia for bidimensional reconstruction of temperature patterns.
    Dubois L; Pribetich J; Fabre JJ; Chive M; Moschetto Y
    Int J Hyperthermia; 1993; 9(3):415-31. PubMed ID: 8515144
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Flow patterns and heat convection in a rectangular water bolus for use in superficial hyperthermia.
    Birkelund Y; Jacobsen S; Arunachalam K; Maccarini P; Stauffer PR
    Phys Med Biol; 2009 Jul; 54(13):3937-53. PubMed ID: 19494426
    [TBL] [Abstract][Full Text] [Related]  

  • 39. FDTD simulations of Clini-Therm applicators on inhomogeneous planar tissue models.
    Chan KW; McDougall JA; Chou CK
    Int J Hyperthermia; 1995; 11(6):809-20. PubMed ID: 8586902
    [TBL] [Abstract][Full Text] [Related]  

  • 40. A new design of microwave interstitial applicators for hyperthermia with improved treatment volume.
    Lee DJ; O'Neill MJ; Lam KS; Rostock R; Lam WC
    Int J Radiat Oncol Biol Phys; 1986 Nov; 12(11):2003-8. PubMed ID: 3771319
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.