These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

178 related articles for article (PubMed ID: 20033789)

  • 41. A new microwave applicator with integrated cooling system for intracavitary hyperthermia of vaginal carcinoma.
    Roos D; Seegenschmiedt MH; Klautke G; Erb J; Sorbe B
    Int J Hyperthermia; 1996; 12(6):743-56. PubMed ID: 8950155
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Control of interstitial thermal coagulation: comparative evaluation of microwave and ultrasound applicators.
    Deardorff DL; Diederich CJ; Nau WH
    Med Phys; 2001 Jan; 28(1):104-17. PubMed ID: 11213915
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Large stationary microstrip arrays for superficial microwave hyperthermia at 433 MHz: SAR analysis and clinical data.
    Ryan TP; Backus VL; Coughlin CT
    Int J Hyperthermia; 1995; 11(2):187-209. PubMed ID: 7790734
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Technical aspects of microwave thermotherapy.
    Vrba J; Lapes M; Oppl L
    Bioelectrochem Bioenerg; 1999 May; 48(2):305-9. PubMed ID: 10379544
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Vesicoureteral reflux in children: a phantom study of microwave heating and radiometric thermometry of pediatric bladder.
    Birkelund Y; Klemetsen Ø; Jacobsen SK; Arunachalam K; Maccarini P; Stauffer PR
    IEEE Trans Biomed Eng; 2011 Nov; 58(11):3269-78. PubMed ID: 21900069
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Absorbed power distributions from single or multiple waveguide applicators during microwave hyperthermia.
    Antolini R; Cerri G; Cristoforetti L; De Leo R
    Phys Med Biol; 1986 Sep; 31(9):1005-19. PubMed ID: 3774873
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Miniature microwave applicator for murine bladder hyperthermia studies.
    Salahi S; Maccarini PF; Rodrigues DB; Etienne W; Landon CD; Inman BA; Dewhirst MW; Stauffer PR
    Int J Hyperthermia; 2012; 28(5):456-65. PubMed ID: 22690856
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Thermal and SAR characterization of multielement dual concentric conductor microwave applicators for hyperthermia, a theoretical investigation.
    Rossetto F; Diederich CJ; Stauffer PR
    Med Phys; 2000 Apr; 27(4):745-53. PubMed ID: 10798697
    [TBL] [Abstract][Full Text] [Related]  

  • 49. An easy-to-use microwave hyperthermia system combined with spatially resolved MR temperature maps: phantom and animal studies.
    Demura K; Morikawa S; Murakami K; Sato K; Shiomi H; Naka S; Kurumi Y; Inubushi T; Tani T
    J Surg Res; 2006 Sep; 135(1):179-86. PubMed ID: 16580694
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Contact flexible microstrip applicators (CFMA) in a range from microwaves up to short waves.
    Gelvich EA; Mazokhin VN
    IEEE Trans Biomed Eng; 2002 Sep; 49(9):1015-23. PubMed ID: 12214873
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Microwave hyperthermia for choroidal melanoma in rabbits.
    Swift PS; Stauffer PR; Fries PD; Kaleta-Michaels S; Murray T; Sneed PK; Phillips TL; Char DH
    Invest Ophthalmol Vis Sci; 1990 Sep; 31(9):1754-60. PubMed ID: 2211023
    [TBL] [Abstract][Full Text] [Related]  

  • 52. A new coaxial TEM radiofrequency/microwave applicator for non-invasive deep-body hyperthermia.
    Lagendijk JJ
    J Microw Power; 1983 Dec; 18(4):367-75. PubMed ID: 6561256
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Development of microwave antennas for thermal therapy.
    Ito K; Saito K
    Curr Pharm Des; 2011; 17(22):2360-6. PubMed ID: 21736543
    [TBL] [Abstract][Full Text] [Related]  

  • 54. A new capacitive heating applicator for the simultaneous radiohyperthermotherapy of superficial and shallow-seated tumors.
    Tanaka A; Kuroda M; Inamura K; Kawasaki S; Hiraki Y
    Acta Med Okayama; 1994 Aug; 48(4):211-6. PubMed ID: 7817776
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Automatic temperature controller for multielement array hyperthermia systems.
    Johnson JE; Maccarini PF; Neuman D; Stauffer PR
    IEEE Trans Biomed Eng; 2006 Jun; 53(6):1006-15. PubMed ID: 16761827
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Spiral microstrip hyperthermia applicators: technical design and clinical performance.
    Samulski TV; Fessenden P; Lee ER; Kapp DS; Tanabe E; McEuen A
    Int J Radiat Oncol Biol Phys; 1990 Jan; 18(1):233-42. PubMed ID: 2298626
    [TBL] [Abstract][Full Text] [Related]  

  • 57. [Intracavitary and interstitial hyperthermia with the 2 mm diameter microwave applicator].
    Ebe K; Nomura S; Suda H; Homma Y; Ariyoshi I; Choji T; Nishikawa E; Nakada T; Nakanishi T
    Nihon Igaku Hoshasen Gakkai Zasshi; 1990 Apr; 50(4):432-4. PubMed ID: 2388815
    [TBL] [Abstract][Full Text] [Related]  

  • 58. SAR deposition by curved CFMA-434 applicators for superficial hyperthermia: Measurements and simulations.
    Petra Kok H; Correia D; De Greef M; Van Stam G; Bel A; Crezee J
    Int J Hyperthermia; 2010; 26(2):171-84. PubMed ID: 20146571
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Design and construction of resonant cavity applicator for brain tumor hyperthermia treatment without contact.
    Takahashi Y; Kato K; Tsuchiya K; Yabuhara T; Uzuka T; Takahashi H
    Conf Proc IEEE Eng Med Biol Soc; 2006; 2006():4074-7. PubMed ID: 17945823
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Cardiac tissue ablation with catheter-based microwave heating.
    Rappaport C
    Int J Hyperthermia; 2004 Nov; 20(7):769-80. PubMed ID: 15675671
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.