These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

175 related articles for article (PubMed ID: 20035175)

  • 1. Extra-articular distal tibia fractures: a mechanical evaluation of 4 different treatment methods.
    Hoenig M; Gao F; Kinder J; Zhang LQ; Collinge C; Merk BR
    J Orthop Trauma; 2010 Jan; 24(1):30-5. PubMed ID: 20035175
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Does fibular plating improve alignment after intramedullary nailing of distal metaphyseal tibia fractures?
    Egol KA; Weisz R; Hiebert R; Tejwani NC; Koval KJ; Sanders RW
    J Orthop Trauma; 2006 Feb; 20(2):94-103. PubMed ID: 16462561
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The effect of concurrent fibular fracture on the fixation of distal tibia fractures: a laboratory comparison of intramedullary nails with locked plates.
    Strauss EJ; Alfonso D; Kummer FJ; Egol KA; Tejwani NC
    J Orthop Trauma; 2007 Mar; 21(3):172-7. PubMed ID: 17473753
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Biomechanical comparison of polyaxial and uniaxial locking plate fixation in a proximal tibial gap model.
    Cullen AB; Curtiss S; Lee MA
    J Orthop Trauma; 2009 Aug; 23(7):507-13. PubMed ID: 19633460
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Angular stability potentially permits fewer locking screws compared with conventional locking in intramedullary nailed distal tibia fractures: a biomechanical study.
    Gueorguiev B; Ockert B; Schwieger K; Wähnert D; Lawson-Smith M; Windolf M; Stoffel K
    J Orthop Trauma; 2011 Jun; 25(6):340-6. PubMed ID: 21577069
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Does a volar locking plate provide equivalent stability as a dorsal nonlocking plate in a dorsally comminuted distal radius fracture?: a biomechanical study.
    Kandemir U; Matityahu A; Desai R; Puttlitz C
    J Orthop Trauma; 2008 Oct; 22(9):605-10. PubMed ID: 18827589
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Angle stable interlocking screws improve construct stability of intramedullary nailing of distal tibia fractures: a biomechanical study.
    Horn J; Linke B; Höntzsch D; Gueorguiev B; Schwieger K
    Injury; 2009 Jul; 40(7):767-71. PubMed ID: 19450799
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Intramedullary nailing versus percutaneous locked plating of extra-articular proximal tibial fractures: comparison of 56 cases.
    Lindvall E; Sanders R; Dipasquale T; Herscovici D; Haidukewych G; Sagi C
    J Orthop Trauma; 2009 Aug; 23(7):485-92. PubMed ID: 19633457
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Biomechanical study of four palmar locking plates and one non-locking palmar plate for distal radius fractures: stiffness and load to failure tests in a cadaver model].
    Rudig L; Mehling I; Klitscher D; Mehler D; Prommersberger KJ; Rommens PM; Müller LP
    Biomed Tech (Berl); 2009 Jun; 54(3):150-8. PubMed ID: 19469665
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Fatigue Failure in Extra-Articular Proximal Tibia Fractures: Locking Intramedullary Nail Versus Double Locking Plates-A Biomechanical Study.
    Kandemir U; Herfat S; Herzog M; Viscogliosi P; Pekmezci M
    J Orthop Trauma; 2017 Feb; 31(2):e49-e54. PubMed ID: 28129271
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Biomechanical comparison of intramedullar versus extramedullar stabilization of intra-articular tibial plateau fractures.
    Högel F; Hoffmann S; Panzer S; Wimber J; Bühren V; Augat P
    Arch Orthop Trauma Surg; 2013 Jan; 133(1):59-64. PubMed ID: 23076657
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A biomechanical comparison of two volar locked plates in a dorsally unstable distal radius fracture model.
    Liporace FA; Kubiak EN; Jeong GK; Iesaka K; Egol KA; Koval KJ
    J Trauma; 2006 Sep; 61(3):668-72. PubMed ID: 16967005
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Interfragmentary movement in diaphyseal tibia fractures fixed with locked intramedullary nails.
    Augat P; Penzkofer R; Nolte A; Maier M; Panzer S; v Oldenburg G; Pueschl K; Simon U; Bühren V
    J Orthop Trauma; 2008 Jan; 22(1):30-6. PubMed ID: 18176162
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of a novel, nonspanning external fixator for treatment of unstable extra-articular fractures of the distal radius: biomechanical comparison with a volar locking plate.
    Strauss EJ; Banerjee D; Kummer FJ; Tejwani NC
    J Trauma; 2008 Apr; 64(4):975-81. PubMed ID: 18404064
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Biomechanical strength of the Peri-Loc proximal tibial plate: a comparison of all-locked versus hybrid locked/nonlocked screw configurations.
    Estes C; Rhee P; Shrader MW; Csavina K; Jacofsky MC; Jacofsky DJ
    J Orthop Trauma; 2008; 22(5):312-6. PubMed ID: 18448984
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A three-dimensional comparison of intramedullary nail constructs for osteopenic supracondylar femur fractures.
    Paller DJ; Frenzen SW; Bartlett CS; Beardsley CL; Beynnon BD
    J Orthop Trauma; 2013 Feb; 27(2):93-9. PubMed ID: 22534687
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Volar fixation for dorsally angulated extra-articular fractures of the distal radius: a biomechanical study.
    Koh S; Morris RP; Patterson RM; Kearney JP; Buford WL; Viegas SF
    J Hand Surg Am; 2006; 31(5):771-9. PubMed ID: 16713841
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The Retrograde Tibial Nail: presentation and biomechanical evaluation of a new concept in the treatment of distal tibia fractures.
    Kuhn S; Appelmann P; Pairon P; Mehler D; Rommens PM
    Injury; 2014 Jan; 45 Suppl 1():S81-6. PubMed ID: 24225228
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Intramedullary stabilization of extraarticular proximal tibial fractures: a biomechanical comparison of intramedullary and extramedullary implants including a new proximal tibia nail (PTN).
    Hansen M; Mehler D; Hessmann MH; Blum J; Rommens PM
    J Orthop Trauma; 2007; 21(10):701-9. PubMed ID: 17986887
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Biomechanical research in treating unstable Pilon fracture with anatomic plate of distal tibia].
    Cui Y; Wang YJ; Hua QK; Cai SQ; Yan LM; Chen KJ
    Zhongguo Gu Shang; 2009 Jul; 22(7):519-21. PubMed ID: 19705717
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.