These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

143 related articles for article (PubMed ID: 20035390)

  • 1. Interassay reproducibility of myocardial perfusion gated SPECT in patients with atrial fibrillation.
    Aguadé-Bruix S; Romero-Farina G; Cuberas-Borros G; Milà-Lopez M; Pubul-Núñez V; Siurana-Escuer R; García-Dorado D; Candell-Riera J
    J Nucl Cardiol; 2010 Jun; 17(3):450-8. PubMed ID: 20035390
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of two software in gated myocardial perfusion single photon emission tomography, for the measurement of left ventricular volumes and ejection fraction, in patients with and without perfusion defects.
    Kakhki VR; Zakavi SR; Sadeghi R
    Hell J Nucl Med; 2007; 10(1):19-23. PubMed ID: 17450245
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Quantification of left ventricular volumes and ejection fraction from gated 99mTc-MIBI SPECT: MRI validation and comparison of the Emory Cardiac Tool Box with QGS and 4D-MSPECT.
    Schaefer WM; Lipke CS; Standke D; Kühl HP; Nowak B; Kaiser HJ; Koch KC; Buell U
    J Nucl Med; 2005 Aug; 46(8):1256-63. PubMed ID: 16085580
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Quantification of left ventricular volumes and ejection fraction from gated 99mTc-MIBI SPECT: MRI validation of the EXINI heart software package.
    Winz OH; Meyer PT; Knollmann D; Lipke CS; Kühl HP; Oelve C; Schaefer WM
    Clin Physiol Funct Imaging; 2009 Apr; 29(2):89-94. PubMed ID: 19076730
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison between 99mTc-sestamibi gated myocardial perfusion SPECT and echocardiography in assessment of left ventricular volumes and ejection fraction--effect of perfusion defect and small heart.
    Danesh-Sani SH; Zakavi SR; Oskoueian L; Kakhki VR
    Nucl Med Rev Cent East Eur; 2014; 17(2):70-4. PubMed ID: 25088105
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison of left ventricular functional parameters obtained from three different commercial automated software cardiac quantification program packages and their intraobserver reproducibility.
    Dostbil Z; Arıtürk Z; Cil H; Elbey MA; Tekbaş E; Yazıcı M; Yıldız I; Taşdemir B
    Ann Nucl Med; 2011 Feb; 25(2):125-31. PubMed ID: 21104169
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of Left Ventricular Volumes and Ejection Fraction from Gated Myocardial Perfusion SPECT Processed with "Myovation Evolution": Comparison of Three Automated Software Packages using Cardiac Magnetic Resonance as Reference.
    Calandri E; Guana F; Pultrone M; Leuzzi S; Chiorino G; Soligo E; Frantellizzi V; Gallina S; Liberatore M; De Vincentis G
    Curr Radiopharm; 2021; 14(2):112-120. PubMed ID: 32933466
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Assessment of left ventricular volume and ejection fraction: comparison of QGS and MBGS analyses of ECG-gated myocardial perfusion SPECT imaging.
    Khorsand A; Gyöngyösi M; Graf S; Zamini S; Schuster E; Sochor H; Porenta G
    Nucl Med Commun; 2009 Apr; 30(4):300-7. PubMed ID: 19357490
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Evaluation of left ventricular volumes and ejection fraction by gated SPECT and cardiac MRI in patients with dilated cardiomyopathy.
    Wang F; Zhang J; Fang W; Zhao SH; Lu MJ; He ZX
    Eur J Nucl Med Mol Imaging; 2009 Oct; 36(10):1611-21. PubMed ID: 19377903
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Validation of 4D-MSPECT and QGS for quantification of left ventricular volumes and ejection fraction from gated 99mTc-MIBI SPET: comparison with cardiac magnetic resonance imaging.
    Lipke CS; Kühl HP; Nowak B; Kaiser HJ; Reinartz P; Koch KC; Buell U; Schaefer WM
    Eur J Nucl Med Mol Imaging; 2004 Apr; 31(4):482-90. PubMed ID: 14722679
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of Gated SPECT Myocardial Perfusion Imaging with Echocardiography for the Measurement of Left Ventricular Volumes and Ejection Fraction in Patients With Severe Heart Failure.
    Shojaeifard M; Ghaedian T; Yaghoobi N; Malek H; Firoozabadi H; Bitarafan-Rajabi A; Haghjoo M; Amin A; Azizian N; Rastgou F
    Res Cardiovasc Med; 2016 Feb; 5(1):e29005. PubMed ID: 26889455
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Variability of left ventricular ejection fraction and volumes with quantitative gated SPECT: influence of algorithm, pixel size and reconstruction parameters in small and normal-sized hearts.
    Hambye AS; Vervaet A; Dobbeleir A
    Eur J Nucl Med Mol Imaging; 2004 Dec; 31(12):1606-13. PubMed ID: 15290114
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Ejection fractions determined by cardiac computed tomographic angiography and single photon emission computed tomographic myocardial perfusion imaging are not interchangeable: evidence of significant and sex-associated disparities.
    Mehta A; Travin MI; Levsky JM; Jain VR; Burton WB; Haramati LB
    J Comput Assist Tomogr; 2009; 33(4):489-97. PubMed ID: 19638838
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of the left ventricular hemodynamic function and myocardial perfusion by gated single photon emission tomography, in patients with type 1 diabetes mellitus; prodromal signs of cardiovascular disease after four years.
    Chrapko B; Kowalczyk M; Nocuń A; Nowakowski A; Zaorska-Rajca J
    Hell J Nucl Med; 2006; 9(2):90-3. PubMed ID: 16894411
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Gated myocardial perfusion SPECT: algorithm-specific influence of reorientation on calculation of left ventricular volumes and ejection fraction.
    Knollmann D; Winz OH; Meyer PT; Raptis M; Krohn T; Koch KC; Schaefer WM
    J Nucl Med; 2008 Oct; 49(10):1636-42. PubMed ID: 18794266
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Left ventricular function parameters obtained from gated myocardial perfusion SPECT imaging: a comparison of two data processing systems.
    Tout DA; Rogers A; Van Aswegen A; Underwood SR
    Nucl Med Commun; 2005 Feb; 26(2):103-7. PubMed ID: 15657501
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A comparison and validation of blood-pool imaging and ECG-gated SPET myocardial perfusion imaging to assess left ventricular ejection fraction.
    Xia W; Lv Z; Wang G; Cai H; Ni J; Zhang Y; Ye B
    Hell J Nucl Med; 2010; 13(3):241-5. PubMed ID: 21193878
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Performance of thallium-201 electrocardiography-gated myocardial perfusion single photon emission computed tomography to assess left ventricular function.
    Hung GU; Hsia CH; Yang PT; Yang KT
    Kaohsiung J Med Sci; 2005 May; 21(5):203-11. PubMed ID: 15960066
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Thallium-gated SPECT in patients with major myocardial infarction: effect of filtering and zooming in comparison with equilibrium radionuclide imaging and left ventriculography.
    Véra P; Manrique A; Pontvianne V; Hitzel A; Koning R; Cribier A
    J Nucl Med; 1999 Apr; 40(4):513-21. PubMed ID: 10210208
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Left ventricular ejection fraction and volumes on rest gated 201Tl perfusion SPECT: comparison with two-dimensional echocardiography.
    Patel CD; Nadig MR; Kurien S; Barai S; Narang R; Malhotra A
    Nucl Med Commun; 2006 May; 27(5):425-9. PubMed ID: 16609353
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.