These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

240 related articles for article (PubMed ID: 20041968)

  • 1. Under-filled blood collection tubes containing K2EDTA as anticoagulant are acceptable for automated complete blood counts, white blood cell differential, and reticulocyte count.
    Xu M; Robbe VA; Jack RM; Rutledge JC
    Int J Lab Hematol; 2010 Oct; 32(5):491-7. PubMed ID: 20041968
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of glass K3EDTA versus plastic K2EDTA blood-drawing tubes for complete blood counts, reticulocyte counts, and white blood cell differentials.
    Van Cott EM; Lewandrowski KB; Patel S; Grzybek DY; Patel HS; Fletcher SR; Kratz A
    Lab Hematol; 2003; 9(1):10-4. PubMed ID: 12661823
    [TBL] [Abstract][Full Text] [Related]  

  • 3. White blood cell counts by automated and manual methods with backlighting.
    Trinh M
    Clin Lab Sci; 1991; 4(1):45-7. PubMed ID: 10149412
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of complete blood counts in samples obtained from healthy dogs and cats by use of standard and microsample blood collection tubes.
    Whittemore JC; Flatland B
    J Am Vet Med Assoc; 2010 Aug; 237(3):281-7. PubMed ID: 20673108
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Performance evaluation of the Sysmex XT-2000i automated hematology analyzer.
    Langford K; Luchtman-Jones L; Miller R; Walck D
    Lab Hematol; 2003; 9(1):29-37. PubMed ID: 12661825
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluation of the Beckman Coulter AcT 5 diff AL hematology analyzer in a hospital setting.
    Bhuta UM; Ulstein H
    Lab Hematol; 2003; 9(3):167-74. PubMed ID: 14521325
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Measurement of total and differential white blood cell counts in synovial fluid by means of an automated hematology analyzer.
    Sugiuchi H; Ando Y; Manabe M; Nakamura E; Mizuta H; Nagata S; Okabe H
    J Lab Clin Med; 2005 Jul; 146(1):36-42. PubMed ID: 16025090
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effect of different anticoagulant, underfilling of blood sample and storage stability on selected hemogram.
    Chen BH; Fong JF; Chiang CH
    Kaohsiung J Med Sci; 1999 Feb; 15(2):87-93. PubMed ID: 10089718
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Impact of under-filled blood collection tubes containing K2EDTA and K3EDTA as anticoagulants on automated complete blood count (CBC) testing.
    Biljak VR; Božičević S; Krhač M; Lovrenčić MV
    Clin Chem Lab Med; 2016 Nov; 54(11):e323-e326. PubMed ID: 27028737
    [No Abstract]   [Full Text] [Related]  

  • 10. False-positive flag of WBC and change of mean platelet volume (MPV) caused by K3-EDTA on the DxH 900 hematology analyzer.
    Park S; Huh J; Jeong TD
    Scand J Clin Lab Invest; 2020 Dec; 80(8):644-648. PubMed ID: 32975447
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Automated five-part white blood cell differential counts. Efficiency of software-generated white blood cell suspect flags of the hematology analyzers Sysmex SE-9000, Sysmex NE-8000, and Coulter STKS.
    Thalhammer-Scherrer R; Knöbl P; Korninger L; Schwarzinger I
    Arch Pathol Lab Med; 1997 Jun; 121(6):573-7. PubMed ID: 9199621
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The effects of over-anticoagulated blood on hematocrit values by the microcentrifuge method.
    Bamberg R; Gwyn T; Miller J; Thompson M; Transou P
    Clin Lab Sci; 2008; 21(3):146-50. PubMed ID: 18678135
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effects of the blood-collection tube material and long-term storage on platelet activation parameters on the ADVIA 120/2120 hematology system.
    Van Cott EM; Fletcher SR; Kratz A
    Lab Hematol; 2005; 11(1):71-5. PubMed ID: 15790555
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Electronic blood cell counters. Faulty calibration due to type and amount of anticoagulant in collection tubes.
    Sears D; Charache S; Perlstein M
    Arch Pathol Lab Med; 1985 Mar; 109(3):247-9. PubMed ID: 3919686
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Performance evaluation of the ADVIA 2120 hematology analyzer: an international multicenter clinical trial.
    Harris N; Jou JM; Devoto G; Lotz J; Pappas J; Wranovics D; Wilkinson M; Fletcher SR; Kratz A
    Lab Hematol; 2005; 11(1):62-70. PubMed ID: 15790554
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Performance evaluation of the Sysmex pocH-100i automated hematology analyzer.
    Whisler S; Dahlgren C
    Lab Hematol; 2005; 11(2):107-17. PubMed ID: 16024334
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Automated haematology analysers: a four-way comparison.
    Warner BA; Reardon DM; Marshall DP
    Med Lab Sci; 1990 Oct; 47(4):285-96. PubMed ID: 2283932
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Comparative and simultaneous evaluation of three automated counters in hematology: Coulter STKS, Sysmex NE 8000, Technicon H-2].
    Cart-Lamy P; Pernod G; Pirraud M; Drevait JM; Caillat D; Polack B; Kolodié L
    Ann Biol Clin (Paris); 1993; 51(6):627-35. PubMed ID: 8172402
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation of the automated hematology analyzer Sysmex XT-2000iV ™ compared to the ADVIA ® 2120 for its use in dogs, cats, and horses. Part II: Accuracy of leukocyte differential and reticulocyte count, impact of anticoagulant and sample aging.
    Bauer N; Nakagawa J; Dunker C; Failing K; Moritz A
    J Vet Diagn Invest; 2012 Jan; 24(1):74-89. PubMed ID: 22362937
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Hemostasis test compatibility with capped and uncapped tubes.
    Finnegan K; Cutsforth G
    Clin Lab Sci; 2011; 24(4):215-20. PubMed ID: 22288219
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.