BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

260 related articles for article (PubMed ID: 20044508)

  • 1. Clinical experience with high-viscosity cements for percutaneous vertebral body augmentation: occurrence, degree, and location of cement leakage compared with kyphoplasty.
    Georgy BA
    AJNR Am J Neuroradiol; 2010 Mar; 31(3):504-8. PubMed ID: 20044508
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Feasibility, safety and cement leakage in vertebroplasty of osteoporotic and malignant compression fractures using ultra-viscous cement and hydraulic delivery system.
    Georgy BA
    Pain Physician; 2012; 15(3):223-8. PubMed ID: 22622906
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Percutaneous vertebral augmentation: an elevation in adjacent-level fracture risk in kyphoplasty as compared with vertebroplasty.
    Frankel BM; Monroe T; Wang C
    Spine J; 2007; 7(5):575-82. PubMed ID: 17905320
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison between radiofrequency targeted vertebral augmentation and balloon kyphoplasty in the treatment of vertebral compression fractures: addressing factors that affect cement extravasation and distribution.
    Georgy BA
    Pain Physician; 2013; 16(5):E513-8. PubMed ID: 24077201
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Biomechanical evaluation of calcium phosphate-based nanocomposite versus polymethylmethacrylate cement for percutaneous kyphoplasty.
    Lu Q; Liu C; Wang D; Liu H; Yang H; Yang L
    Spine J; 2019 Nov; 19(11):1871-1884. PubMed ID: 31202837
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Kyphoplasty and vertebroplasty produce the same degree of height restoration.
    Hiwatashi A; Westesson PL; Yoshiura T; Noguchi T; Togao O; Yamashita K; Kamano H; Honda H
    AJNR Am J Neuroradiol; 2009 Apr; 30(4):669-73. PubMed ID: 19131409
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Cement leakage in percutaneous vertebroplasty for osteoporotic vertebral compression fractures: identification of risk factors.
    Nieuwenhuijse MJ; Van Erkel AR; Dijkstra PD
    Spine J; 2011 Sep; 11(9):839-48. PubMed ID: 21889417
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Cement directed kyphoplasty reduces cement leakage as compared with vertebroplasty: results of a controlled, randomized trial.
    Vogl TJ; Pflugmacher R; Hierholzer J; Stender G; Gounis M; Wakhloo A; Fiebig C; Hammerstingl R
    Spine (Phila Pa 1976); 2013 Sep; 38(20):1730-6. PubMed ID: 23804157
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Risk factors of non-surgical vertebral fracture after percutaneous kyphoplasty of single segment thoracolumbar fracture].
    Wu J; Guan YH; Fan SL
    Zhongguo Gu Shang; 2017 Sep; 30(9):833-837. PubMed ID: 29455485
    [TBL] [Abstract][Full Text] [Related]  

  • 10. An in vivo comparison of the potential for extravertebral cement leak after vertebroplasty and kyphoplasty.
    Phillips FM; Todd Wetzel F; Lieberman I; Campbell-Hupp M
    Spine (Phila Pa 1976); 2002 Oct; 27(19):2173-8; discussion 2178-9. PubMed ID: 12394934
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of high-viscosity cement vertebroplasty and balloon kyphoplasty for the treatment of osteoporotic vertebral compression fractures.
    Wang CH; Ma JZ; Zhang CC; Nie L
    Pain Physician; 2015; 18(2):E187-94. PubMed ID: 25794218
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Percutaneous Vertebral Augmentation for Osteoporotic Vertebral Compression Fracture in the Midthoracic Vertebrae (T5-8): A Retrospective Study of 101 Patients with 111 Fractured Segments.
    Liu J; Tang J; Zhang Y; Gu ZC; Yu SH
    World Neurosurg; 2019 Feb; 122():e1381-e1387. PubMed ID: 30465955
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of the Efficacy and Safety of Bone-filling Mesh Container and Simple Percutaneous Balloon Kyphoplasty in the Treatment of Osteoporotic Vertebral Compression Fractures.
    He CJ; Liu GD
    Pain Physician; 2018 May; 21(3):259-268. PubMed ID: 29871370
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Cement leakage in osteoporotic vertebral compression fractures with cortical defect using high-viscosity bone cement during unilateral percutaneous kyphoplasty surgery.
    Liu T; Li Z; Su Q; Hai Y
    Medicine (Baltimore); 2017 Jun; 96(25):e7216. PubMed ID: 28640112
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Kyphoplasty for osteoporotic vertebral fractures with posterior wall injury.
    Abdelgawaad AS; Ezzati A; Govindasamy R; Krajnovic B; Elnady B; Said GZ
    Spine J; 2018 Jul; 18(7):1143-1148. PubMed ID: 29154997
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Correlative factor analysis of complications resulting from cement leakage after percutaneous kyphoplasty in treatment of osteoporotic vertebral body compression].
    Shen Y; Ren H; Zhang Y; Zhi X; Ding W; Xu J; Yang D
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2010 Jan; 24(1):27-31. PubMed ID: 20135966
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A comparative study of high-viscosity cement percutaneous vertebroplasty vs. low-viscosity cement percutaneous kyphoplasty for treatment of osteoporotic vertebral compression fractures.
    Sun K; Liu Y; Peng H; Tan JF; Zhang M; Zheng XN; Chen FZ; Li MH
    J Huazhong Univ Sci Technolog Med Sci; 2016 Jun; 36(3):389-394. PubMed ID: 27376809
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Percutaneous vertebroplasty and bone cement leakage: clinical experience with a new high-viscosity bone cement and delivery system for vertebral augmentation in benign and malignant compression fractures.
    Anselmetti GC; Zoarski G; Manca A; Masala S; Eminefendic H; Russo F; Regge D
    Cardiovasc Intervent Radiol; 2008; 31(5):937-47. PubMed ID: 18389186
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Is kyphoplasty reliable for osteoporotic vertebral compression fracture with vertebral wall deficiency?
    Zou J; Mei X; Gan M; Wang G; Lu J; Yang H
    Injury; 2010 Apr; 41(4):360-4. PubMed ID: 19913786
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Efficacy and Safety of High-Viscosity Bone Cement Vertebroplasty in Treatment of Osteoporotic Vertebral Compression Fractures with Intravertebral Cleft.
    Tang S; Fu W; Zhang H; Zhang H; Liang B
    World Neurosurg; 2019 Dec; 132():e739-e745. PubMed ID: 31415893
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.