271 related articles for article (PubMed ID: 20046660)
1. A liquid chromatography/tandem mass spectrometry method for determination of 25-hydroxy vitamin D2 and 25-hydroxy vitamin D3 in dried blood spots: a potential adjunct to diabetes and cardiometabolic risk screening.
Newman MS; Brandon TR; Groves MN; Gregory WL; Kapur S; Zava DT
J Diabetes Sci Technol; 2009 Jan; 3(1):156-62. PubMed ID: 20046660
[TBL] [Abstract][Full Text] [Related]
2. Development of a candidate reference measurement procedure for the determination of 25-hydroxyvitamin D3 and 25-hydroxyvitamin D2 in human serum using isotope-dilution liquid chromatography-tandem mass spectrometry.
Tai SS; Bedner M; Phinney KW
Anal Chem; 2010 Mar; 82(5):1942-8. PubMed ID: 20136128
[TBL] [Abstract][Full Text] [Related]
3. A Rapid and Simple Liquid-Chromatography-Tandem Mass Spectrometry Method for Measuring 25-Hydroxyvitamin D2 and 25-Hydroxyvitamin D3 in Human Serum: Comparison with Two Automated Immunoassays.
Lee S; Kim JH; Kim SA; Sun YS; Lee A; Park SJ; Kim YT; Lee KR; Kim YJ
Ann Clin Lab Sci; 2016 Dec; 46(6):645-653. PubMed ID: 27993879
[TBL] [Abstract][Full Text] [Related]
4. Differential extraction of endogenous and exogenous 25-OH-vitamin D from serum makes the accurate quantification in liquid chromatography-tandem mass spectrometry assays challenging.
Lankes U; Elder PA; Lewis JG; George P
Ann Clin Biochem; 2015 Jan; 52(Pt 1):151-60. PubMed ID: 24714680
[TBL] [Abstract][Full Text] [Related]
5. Routine isotope-dilution liquid chromatography-tandem mass spectrometry assay for simultaneous measurement of the 25-hydroxy metabolites of vitamins D2 and D3.
Maunsell Z; Wright DJ; Rainbow SJ
Clin Chem; 2005 Sep; 51(9):1683-90. PubMed ID: 16020493
[TBL] [Abstract][Full Text] [Related]
6. Vitamin D Status in Children With Short Stature: Accurate Determination of Serum Vitamin D Components Using High-Performance Liquid Chromatography-Tandem Mass Spectrometry.
Xu B; Feng Y; Gan L; Zhang Y; Jiang W; Feng J; Yu L
Front Endocrinol (Lausanne); 2021; 12():707283. PubMed ID: 34721288
[TBL] [Abstract][Full Text] [Related]
7. Application of dried blood spots to determine vitamin D status in a large nutritional study with unsupervised sampling: the Food4Me project.
Hoeller U; Baur M; Roos FF; Brennan L; Daniel H; Fallaize R; Forster H; Gibney ER; Gibney M; Godlewska M; Hartwig K; Kolossa S; Lambrinou CP; Livingstone KM; Lovegrove JA; Macready AL; Manios Y; Marsaux CF; Martinez JA; Celis-Morales C; Moschonis G; Navas-Carretero S; O'Donovan CB; San-Cristobal R; Saris WH; Surwiłło A; Traczyk I; Tsirigoti L; Walsh MC; Woolhead C; Mathers JC; Weber P;
Br J Nutr; 2016 Jan; 115(2):202-11. PubMed ID: 26548417
[TBL] [Abstract][Full Text] [Related]
8. Development and validation of an LC-MS/MS based method for quantification of 25 hydroxyvitamin D2 and 25 hydroxyvitamin D3 in human serum and plasma.
Zhang SW; Jian W; Sullivan S; Sankaran B; Edom RW; Weng N; Sharkey D
J Chromatogr B Analyt Technol Biomed Life Sci; 2014 Jun; 961():62-70. PubMed ID: 24861873
[TBL] [Abstract][Full Text] [Related]
9. Increasing liquid chromatography-tandem mass spectrometry throughput by mass tagging: a sample-multiplexed high-throughput assay for 25-hydroxyvitamin D2 and D3.
Netzel BC; Cradic KW; Bro ET; Girtman AB; Cyr RC; Singh RJ; Grebe SK
Clin Chem; 2011 Mar; 57(3):431-40. PubMed ID: 21245371
[TBL] [Abstract][Full Text] [Related]
10. Development and validation of the simultaneous measurement of four vitamin D metabolites in serum by LC-MS/MS for clinical laboratory applications.
Satoh M; Ishige T; Ogawa S; Nishimura M; Matsushita K; Higashi T; Nomura F
Anal Bioanal Chem; 2016 Nov; 408(27):7617-7627. PubMed ID: 27526091
[TBL] [Abstract][Full Text] [Related]
11. A specific LC/ESI-MS/MS method for determination of 25-hydroxyvitamin D3 in neonatal dried blood spots containing a potential interfering metabolite, 3-epi-25-hydroxyvitamin D3.
Higashi T; Suzuki M; Hanai J; Inagaki S; Min JZ; Shimada K; Toyo'oka T
J Sep Sci; 2011 Apr; 34(7):725-32. PubMed ID: 21328697
[TBL] [Abstract][Full Text] [Related]
12. A novel Cookson-type reagent for enhancing sensitivity and specificity in assessment of infant vitamin D status using liquid chromatography/tandem mass spectrometry.
Ogawa S; Ooki S; Morohashi M; Yamagata K; Higashi T
Rapid Commun Mass Spectrom; 2013 Nov; 27(21):2453-60. PubMed ID: 24097402
[TBL] [Abstract][Full Text] [Related]
13. Analytical evaluation of the BioPlex® 2200 25-OH vitamin D total assay.
Abou El Hassan M; Lin DCC; Earle T; Spencer M; Blasutig IM
Clin Biochem; 2016 Jun; 49(9):723-725. PubMed ID: 27112381
[TBL] [Abstract][Full Text] [Related]
14. Development of a sensitive HPLC-MS/MS method for 25-hydroxyvitamin D
Jiao X; Yuan Y; Wang X; Li J; Liu B; Yuan T; Yu X
J Clin Lab Anal; 2020 Oct; 34(10):e23451. PubMed ID: 32592276
[TBL] [Abstract][Full Text] [Related]
15. Quantification of the 3α and 3β epimers of 25-hydroxyvitamin D
Müller MJ; Stokes CS; Volmer DA
Talanta; 2017 Apr; 165():398-404. PubMed ID: 28153274
[TBL] [Abstract][Full Text] [Related]
16. A candidate reference measurement procedure for quantifying serum concentrations of 25-hydroxyvitamin D₃ and 25-hydroxyvitamin D₂ using isotope-dilution liquid chromatography-tandem mass spectrometry.
Mineva EM; Schleicher RL; Chaudhary-Webb M; Maw KL; Botelho JC; Vesper HW; Pfeiffer CM
Anal Bioanal Chem; 2015 Jul; 407(19):5615-24. PubMed ID: 25967149
[TBL] [Abstract][Full Text] [Related]
17. Overestimation of 25-hydroxyvitamin D3 by increased ionisation efficiency of 3-epi-25-hydroxyvitamin D3 in LC-MS/MS methods not separating both metabolites as determined by an LC-MS/MS method for separate quantification of 25-hydroxyvitamin D3, 3-epi-25-hydroxyvitamin D3 and 25-hydroxyvitamin D2 in human serum.
van den Ouweland JM; Beijers AM; van Daal H
J Chromatogr B Analyt Technol Biomed Life Sci; 2014 Sep; 967():195-202. PubMed ID: 25125396
[TBL] [Abstract][Full Text] [Related]
18. A simple, rapid atmospheric pressure chemical ionization liquid chromatography tandem mass spectrometry method for the determination of 25-hydroxyvitamin D2 and D3.
Garg U; Munar A; Frazee C; Scott D
J Clin Lab Anal; 2012 Sep; 26(5):349-57. PubMed ID: 23001980
[TBL] [Abstract][Full Text] [Related]
19. Rapid liquid chromatography-tandem mass spectrometry method for determination of 24,25(OH)
Yu S; Zhou W; Wang D; Yin Y; Cheng Q; Xie S; Sun D; Li H; Cheng X; Qiu L
J Steroid Biochem Mol Biol; 2019 Mar; 187():146-151. PubMed ID: 30476592
[TBL] [Abstract][Full Text] [Related]
20. Determination of 25-hydroxyvitamin D in human plasma using high-performance liquid chromatography--tandem mass spectrometry.
Tsugawa N; Suhara Y; Kamao M; Okano T
Anal Chem; 2005 May; 77(9):3001-7. PubMed ID: 15859623
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]