These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

171 related articles for article (PubMed ID: 20046962)

  • 1. Micropower CMOS Integrated Low-Noise Amplification, Filtering, and Digitization of Multimodal Neuropotentials.
    Mollazadeh M; Murari K; Cauwenberghs G; Thakor N
    IEEE Trans Biomed Circuits Syst; 2009 Feb; 3(1):1-10. PubMed ID: 20046962
    [TBL] [Abstract][Full Text] [Related]  

  • 2. From spikes to EEG: integrated multichannel and selective acquisition of neuropotentials.
    Mollazadeh M; Murari K; Cauwenberghs G; Thakor N
    Annu Int Conf IEEE Eng Med Biol Soc; 2008; 2008():2741-4. PubMed ID: 19163272
    [TBL] [Abstract][Full Text] [Related]  

  • 3. An energy-efficient micropower neural recording amplifier.
    Wattanapanitch W; Fee M; Sarpeshkar R
    IEEE Trans Biomed Circuits Syst; 2007 Jun; 1(2):136-47. PubMed ID: 23851668
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The design of CMOS general-purpose analog front-end circuit with tunable gain and bandwidth for biopotential signal recording systems.
    Chen WM; Yang WC; Tsai TY; Chiueh H; Wu CY
    Annu Int Conf IEEE Eng Med Biol Soc; 2011; 2011():4784-7. PubMed ID: 22255408
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A low-power configurable neural recording system for epileptic seizure detection.
    Qian C; Shi J; Parramon J; Sánchez-Sinencio E
    IEEE Trans Biomed Circuits Syst; 2013 Aug; 7(4):499-512. PubMed ID: 23893209
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Wireless micropower instrumentation for multimodal acquisition of electrical and chemical neural activity.
    Mollazadeh M; Murari K; Cauwenberghs G; Thakor N
    IEEE Trans Biomed Circuits Syst; 2009 Dec; 3(6):388-97. PubMed ID: 23853286
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A 0.5-V multi-channel low-noise readout front-end for portable EEG acquisition.
    Wen-Yen Huang ; Yu-Wei Cheng ; Kea-Tiong Tang
    Annu Int Conf IEEE Eng Med Biol Soc; 2015 Aug; 2015():837-40. PubMed ID: 26736392
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A 16-Channel CMOS Chopper-Stabilized Analog Front-End ECoG Acquisition Circuit for a Closed-Loop Epileptic Seizure Control System.
    Wu CY; Cheng CH; Chen ZX
    IEEE Trans Biomed Circuits Syst; 2018 Jun; 12(3):543-553. PubMed ID: 29877818
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A low-power programmable neural spike detection channel with embedded calibration and data compression.
    Rodriguez-Perez A; Ruiz-Amaya J; Delgado-Restituto M; Rodriguez-Vazquez Á
    IEEE Trans Biomed Circuits Syst; 2012 Apr; 6(2):87-100. PubMed ID: 23852974
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A 64-channel neuron recording system.
    Lo YK; Liu W; Chen K; Tsai MH; Hsueh FL
    Annu Int Conf IEEE Eng Med Biol Soc; 2011; 2011():2862-5. PubMed ID: 22254938
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A low-power current-reuse dual-band analog front-end for multi-channel neural signal recording.
    Sepehrian H; Gosselin B
    Annu Int Conf IEEE Eng Med Biol Soc; 2014; 2014():5284-7. PubMed ID: 25571186
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A PVT-Robust AFE-Embedded Error-Feedback Noise-Shaping SAR ADC With Chopper-Based Passive High-Pass IIR Filtering for Direct Neural Recording.
    Jeong K; Jung Y; Yun G; Youn D; Jo Y; Lee HJ; Ha S; Je M
    IEEE Trans Biomed Circuits Syst; 2022 Aug; 16(4):679-691. PubMed ID: 35881597
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A low power, low noise Programmable Analog Front End (PAFE) for biopotential measurements.
    Adimulam MK; Divya A; Tejaswi K; Srinivas MB
    Annu Int Conf IEEE Eng Med Biol Soc; 2017 Jul; 2017():3844-3847. PubMed ID: 29060736
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A CMOS power-efficient low-noise current-mode front-end amplifier for neural signal recording.
    Wu CY; Chen WM; Kuo LT
    IEEE Trans Biomed Circuits Syst; 2013 Apr; 7(2):107-14. PubMed ID: 23853293
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Power-to-Noise Optimization in the Design of Neural Recording Amplifier Based on Current Scaling, Source Degeneration Resistor, and Current Reuse.
    Wang Z; Wang X; Shu G; Yin M; Huang S; Yin M
    Biosensors (Basel); 2024 Feb; 14(2):. PubMed ID: 38392030
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A 340 nW/Channel 110 dB PSRR Neural Recording Analog Front-End Using Replica-Biasing LNA, Level-Shifter Assisted PGA, and Averaged LFP Servo Loop in 65 nm CMOS.
    Lyu L; Ye D; Shi CR
    IEEE Trans Biomed Circuits Syst; 2020 Aug; 14(4):811-824. PubMed ID: 32746334
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Continuous Time Level Crossing Sampling ADC for Bio-Potential Recording Systems.
    Tang W; Osman A; Kim D; Goldstein B; Huang C; Martini B; Pieribone VA; Culurciello E
    IEEE Trans Circuits Syst I Regul Pap; 2013 Jun; 60(6):1407-1418. PubMed ID: 24163640
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Low-Cutoff Frequency Reduction in Neural Amplifiers: Analysis and Implementation in CMOS 65 nm.
    Hashemi Noshahr F; Nabavi M; Gosselin B; Sawan M
    Front Neurosci; 2021; 15():667846. PubMed ID: 34149347
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Power-Efficient LFP-Adaptive Dynamic Zoom-and-Track Incremental ΔΣ Front-End for Dual-Band Subcortical Recordings.
    Oh S; Song H; Slager N; Ruiz JRL; Park SY; Yoon E
    IEEE Trans Biomed Circuits Syst; 2023 Aug; 17(4):741-753. PubMed ID: 37490369
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A Low Noise Amplifier for Neural Spike Recording Interfaces.
    Ruiz-Amaya J; Rodriguez-Perez A; Delgado-Restituto M
    Sensors (Basel); 2015 Sep; 15(10):25313-35. PubMed ID: 26437411
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.