These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

125 related articles for article (PubMed ID: 20052166)

  • 1. Design of a high-sensor count fibre optic manometry catheter for in-vivo colonic diagnostics.
    Arkwright JW; Underhill ID; Maunder SA; Blenman N; Szczesniak MM; Wiklendt L; Cook IJ; Lubowski DZ; Dinning PG
    Opt Express; 2009 Dec; 17(25):22423-31. PubMed ID: 20052166
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Low-resolution colonic manometry leads to a gross misinterpretation of the frequency and polarity of propagating sequences: Initial results from fiber-optic high-resolution manometry studies.
    Dinning PG; Wiklendt L; Gibbins I; Patton V; Bampton P; Lubowski DZ; Cook IJ; Arkwright JW
    Neurogastroenterol Motil; 2013 Oct; 25(10):e640-9. PubMed ID: 23773787
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Evaluating the dynamic performance of a fibre optic pressure microsensor.
    Chen S; Pislaru C; Kinnick RR; Morrow DA; Kaufman KR; Greenleaf JF
    Physiol Meas; 2005 Aug; 26(4):N13-9. PubMed ID: 15886426
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Sensitive liquid refractive index sensors using tapered optical fiber tips.
    Tai YH; Wei PK
    Opt Lett; 2010 Apr; 35(7):944-6. PubMed ID: 20364178
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Low-cost high-performance fiber-optic pH sensor based on thin-core fiber modal interferometer.
    Gu B; Yin MJ; Zhang AP; Qian JW; He S
    Opt Express; 2009 Dec; 17(25):22296-302. PubMed ID: 20052152
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Fabrication of a compact reflective long-period grating sensor with a cladding-mode-selective fiber end-face mirror.
    Jiang M; Zhang AP; Wang YC; Tam HY; He S
    Opt Express; 2009 Sep; 17(20):17976-82. PubMed ID: 19907586
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Theoretical analysis of a fiber optic surface plasmon resonance sensor utilizing a Bragg grating.
    Spacková B; Homola J
    Opt Express; 2009 Dec; 17(25):23254-64. PubMed ID: 20052251
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Phase modulation with micromachined resonant mirrors for low-coherence fiber-tip pressure sensors.
    Zhang XM; Liu Y; Bae H; Pang C; Yu M
    Opt Express; 2009 Dec; 17(26):23965-74. PubMed ID: 20052107
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Dual polarization fiber grating laser hydrophone.
    Guan BO; Tan YN; Tam HY
    Opt Express; 2009 Oct; 17(22):19544-50. PubMed ID: 19997174
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Side-hole fiber sensor based on surface plasmon resonance.
    Wang A; Docherty A; Kuhlmey BT; Cox FM; Large MC
    Opt Lett; 2009 Dec; 34(24):3890-2. PubMed ID: 20016648
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Miniature all-glass robust pressure sensor.
    Cibula E; Pevec S; Lenardic B; Pinet E; Donlagic D
    Opt Express; 2009 Mar; 17(7):5098-106. PubMed ID: 19333272
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Design of a test system for fast time response fibre optic oxygen sensors.
    Saied A; Edgington L; Gale L; Palayiwa E; Belcher R; Farmery AD; Chen R; Hahn CE
    Physiol Meas; 2010 Apr; 31(4):N25-33. PubMed ID: 20208094
    [TBL] [Abstract][Full Text] [Related]  

  • 13. MEMS Bragg grating force sensor.
    Reck K; Thomsen EV; Hansen O
    Opt Express; 2011 Sep; 19(20):19190-8. PubMed ID: 21996861
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Demonstration of an ultra-wideband optical fiber inline polarizer with metal nano-grid on the fiber tip.
    Lin Y; Guo J; Lindquist RG
    Opt Express; 2009 Sep; 17(20):17849-54. PubMed ID: 19907572
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Macrobending single-mode fiber-based refractometer.
    Wang P; Semenova Y; Wu Q; Farrell G; Ti Y; Zheng J
    Appl Opt; 2009 Nov; 48(31):6044-9. PubMed ID: 19881672
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Improved pressure-frequency sensing subxiphoid pericardial access system: performance characteristics during in vivo testing.
    Tucker-Schwartz JM; Gillies GT; Mahapatra S
    IEEE Trans Biomed Eng; 2011 Apr; 58(4):845-52. PubMed ID: 21147589
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Analytical coherency matrix treatment of shear strained fiber Bragg gratings.
    Müller MS; Schnarr CD
    Opt Express; 2009 Dec; 17(25):22624-31. PubMed ID: 20052188
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Improving the reliability of multiplexed fiber optic low-coherence interferometric sensors by use of novel twin-loop network topologies.
    Yang J; Yuan L; Jin W
    Rev Sci Instrum; 2007 May; 78(5):055106. PubMed ID: 17552859
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Two dimensional polymer-embedded quasi-distributed FBG pressure sensor for biomedical applications.
    Kanellos GT; Papaioannou G; Tsiokos D; Mitrogiannis C; Nianios G; Pleros N
    Opt Express; 2010 Jan; 18(1):179-86. PubMed ID: 20173837
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Optical fiber refractometer based on cladding-mode Bragg grating.
    Han M; Guo F; Lu Y
    Opt Lett; 2010 Feb; 35(3):399-401. PubMed ID: 20125734
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.