These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
104 related articles for article (PubMed ID: 20061664)
1. Effect of high-pass filtering on ECG signal on the analysis of patients prone to atrial fibrillation. Censi F; Calcagnini G; Triventi M; Mattei E; Bartolini P; Corazza I; Boriani G Ann Ist Super Sanita; 2009; 45(4):427-31. PubMed ID: 20061664 [TBL] [Abstract][Full Text] [Related]
2. Influence of filtering techniques on the time-domain analysis of signal-averaged P wave electrocardiogram. Valverde ER; Quinteiro RA; Bertran GC; Arini PD; Glenny P; Biagetti MO J Cardiovasc Electrophysiol; 1998 Mar; 9(3):253-60. PubMed ID: 9554730 [TBL] [Abstract][Full Text] [Related]
3. Non-invasive assessment of fibrillatory activity in patients with paroxysmal and persistent atrial fibrillation using the Holter ECG. Bollmann A; Sonne K; Esperer HD; Toepffer I; Langberg JJ; Klein HU Cardiovasc Res; 1999 Oct; 44(1):60-6. PubMed ID: 10615390 [TBL] [Abstract][Full Text] [Related]
4. ECG baseline wander reduction using linear phase filters. van Alsté JA; van Eck W; Herrmann OE Comput Biomed Res; 1986 Oct; 19(5):417-27. PubMed ID: 3769470 [TBL] [Abstract][Full Text] [Related]
5. Time-varying digital filtering of ECG baseline wander. Sörnmo L Med Biol Eng Comput; 1993 Sep; 31(5):503-8. PubMed ID: 8295440 [TBL] [Abstract][Full Text] [Related]
6. Ranking of the most reliable beat morphology and heart rate variability features for the detection of atrial fibrillation in short single-lead ECG. Christov I; Krasteva V; Simova I; Neycheva T; Schmid R Physiol Meas; 2018 Sep; 39(9):094005. PubMed ID: 30102603 [TBL] [Abstract][Full Text] [Related]
7. [The prediction of atrial fibrillation recurrence after electrical cardioversion with P wave signal averaged EKG]. Budeus M; Hennersdorf M; Perings C; Strauer BE Z Kardiol; 2004 Jun; 93(6):474-8. PubMed ID: 15252741 [TBL] [Abstract][Full Text] [Related]
8. Long-term outcome after cardioversion of atrial fibrillation: prediction of recurrence with P wave signal averaged ECG and chemoreflexsensitivity. Budeus M; Wieneke H; Sack S; Erbel R; Perings C Int J Cardiol; 2006 Oct; 112(3):308-15. PubMed ID: 16309759 [TBL] [Abstract][Full Text] [Related]
9. Usefulness of P-Wave Duration and Morphologic Variability to Identify Patients Prone to Paroxysmal Atrial Fibrillation. Conte G; Luca A; Yazdani S; Caputo ML; Regoli F; Moccetti T; Kappenberger L; Vesin JM; Auricchio A Am J Cardiol; 2017 Jan; 119(2):275-279. PubMed ID: 27823601 [TBL] [Abstract][Full Text] [Related]
10. Prediction of atrial fibrillation recurrence after cardioversion by P wave signal-averaged electrocardiography. Aytemir K; Aksoyek S; Yildirir A; Ozer N; Oto A Int J Cardiol; 1999 Jul; 70(1):15-21. PubMed ID: 10402041 [TBL] [Abstract][Full Text] [Related]
11. Evaluation of P wave signal-averaged electrocardiographic filtering and analysis methods. Ehlert FA; Korenstein D; Steinberg JS Am Heart J; 1997 Dec; 134(6):985-93. PubMed ID: 9424056 [TBL] [Abstract][Full Text] [Related]
12. Detection of patients at risk for recurrence of atrial fibrillation after successful electrical cardioversion by signal-averaged P-wave ECG. Opolski G; Scisło P; Stanisławska J; Górecki A; Steckiewicz R; Torbicki A Int J Cardiol; 1997 Jul; 60(2):181-5. PubMed ID: 9226289 [TBL] [Abstract][Full Text] [Related]
13. High-pass filtering to remove electrocardiographic interference from torso EMG recordings. Redfern M; Hughes R; Chaffin D Clin Biomech (Bristol); 1993 Jan; 8(1):44-8. PubMed ID: 23915829 [TBL] [Abstract][Full Text] [Related]
14. Can heart rate variability parameters derived by a heart rate monitor differentiate between atrial fibrillation and sinus rhythm? Broux B; De Clercq D; Vera L; Ven S; Deprez P; Decloedt A; van Loon G BMC Vet Res; 2018 Oct; 14(1):320. PubMed ID: 30359273 [TBL] [Abstract][Full Text] [Related]
15. Graphics-processor-unit-based parallelization of optimized baseline wander filtering algorithms for long-term electrocardiography. Niederhauser T; Wyss-Balmer T; Haeberlin A; Marisa T; Wildhaber RA; Goette J; Jacomet M; Vogel R IEEE Trans Biomed Eng; 2015 Jun; 62(6):1576-84. PubMed ID: 25675449 [TBL] [Abstract][Full Text] [Related]
16. P wave analysis with wavelets identifies hypertensive patients at risk of recurrence of atrial fibrillation: A case-control study and 1year follow-up. Dakos G; Konstantinou D; Chatzizisis YS; Chouvarda I; Filos D; Paraskevaidis S; Mantziari L; Maglaveras N; Karvounis H; Vassilikos V J Electrocardiol; 2015; 48(5):845-52. PubMed ID: 26216370 [TBL] [Abstract][Full Text] [Related]
17. Prediction of maintenance of sinus rhythm after cardioversion of atrial fibrillation by analysis of serial signal-averaged P waves. Stafford PJ; Kamalvand K; Tan K; Vincent R; Sulke N Pacing Clin Electrophysiol; 1998 Jul; 21(7):1387-95. PubMed ID: 9670182 [TBL] [Abstract][Full Text] [Related]
18. [The high-resolution analysis of the P wave recorded via the esophagus: a new diagnostic approach in patients with paroxysmal atrial fibrillation]. Quinto Villani G; Rosi A; Dieci G; Arruzzoli S; Gazzola U G Ital Cardiol; 1993 Feb; 23(2):139-44. PubMed ID: 8491354 [TBL] [Abstract][Full Text] [Related]
19. An Extended Bayesian Framework for Atrial and Ventricular Activity Separation in Atrial Fibrillation. Roonizi EK; Sassi R IEEE J Biomed Health Inform; 2017 Nov; 21(6):1573-1580. PubMed ID: 27834661 [TBL] [Abstract][Full Text] [Related]