These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
158 related articles for article (PubMed ID: 2006263)
1. Magnetization transfer contrast: method for improving contrast in gradient-recalled-echo images. Wolff SD; Eng J; Balaban RS Radiology; 1991 Apr; 179(1):133-7. PubMed ID: 2006263 [TBL] [Abstract][Full Text] [Related]
2. [Magnetization transfer contrast imaging of the skeletal muscle in gradient recalled echo sequence]. Yoshioka H; Niitsu M; Anno I; Nakajima K; Nishimura H; Kajiyama K; Nakaya C; Itai Y Nihon Igaku Hoshasen Gakkai Zasshi; 1993 Feb; 53(2):223-5. PubMed ID: 8488106 [TBL] [Abstract][Full Text] [Related]
3. MR imaging contrast in human brain tissue: assessment and optimization at 4 T. Duewell S; Wolff SD; Wen H; Balaban RS; Jezzard P Radiology; 1996 Jun; 199(3):780-6. PubMed ID: 8638005 [TBL] [Abstract][Full Text] [Related]
4. Systematic variation of off-resonance prepulses for clinical magnetization transfer contrast imaging at 0.2, 1.5, and 3.0 tesla. Martirosian P; Boss A; Deimling M; Kiefer B; Schraml C; Schwenzer NF; Claussen CD; Schick F Invest Radiol; 2008 Jan; 43(1):16-26. PubMed ID: 18097273 [TBL] [Abstract][Full Text] [Related]
5. Fast multiplanar spoiled gradient-recalled imaging of the liver: pulse sequence optimization and comparison with spin-echo MR imaging. Low RN; Francis IR; Herfkens RJ; Jeffrey RB; Glazer GM; Foo TK; Shimakawa A; Pelc NJ AJR Am J Roentgenol; 1993 Mar; 160(3):501-9. PubMed ID: 8381572 [TBL] [Abstract][Full Text] [Related]
6. Magnetization transfer contrast: MR imaging of the knee. Wolff SD; Chesnick S; Frank JA; Lim KO; Balaban RS Radiology; 1991 Jun; 179(3):623-8. PubMed ID: 2027963 [TBL] [Abstract][Full Text] [Related]
7. Use of magnetization transfer for improved contrast on gradient-echo MR images of the cervical spine. Finelli DA; Hurst GC; Karaman BA; Simon JE; Duerk JL; Bellon EM Radiology; 1994 Oct; 193(1):165-71. PubMed ID: 8090886 [TBL] [Abstract][Full Text] [Related]
8. T1-weighted three-dimensional magnetization transfer MR of the brain: improved lesion contrast enhancement. Finelli DA; Hurst GC; Gullapalli RP AJNR Am J Neuroradiol; 1998 Jan; 19(1):59-64. PubMed ID: 9432158 [TBL] [Abstract][Full Text] [Related]
9. Volumetric method for evaluating magnetization transfer ratio of tissue categories: application to areas of white matter signal hyperintensity in the elderly. Tanabe JL; Ezekiel F; Jagust WJ; Schuff N; Fein G Radiology; 1997 Aug; 204(2):570-5. PubMed ID: 9240555 [TBL] [Abstract][Full Text] [Related]
10. [Comparison of a T1-weighted inversion-recovery-, gradient-echo- and spin-echo sequence for imaging of the brain at 3.0 Tesla]. Stehling C; Niederstadt T; Krämer S; Kugel H; Schwindt W; Heindel W; Bachmann R Rofo; 2005 Apr; 177(4):536-42. PubMed ID: 15838759 [TBL] [Abstract][Full Text] [Related]
11. Improved contrast of enhancing brain lesions on postgadolinium, T1-weighted spin-echo images with use of magnetization transfer. Finelli DA; Hurst GC; Gullapali RP; Bellon EM Radiology; 1994 Feb; 190(2):553-9. PubMed ID: 8284415 [TBL] [Abstract][Full Text] [Related]
12. Conspicuity of tumors of the head and neck on fat-suppressed MR images: T2-weighted fast-spin-echo versus contrast-enhanced T1-weighted conventional spin-echo sequences. Dubin MD; Teresi LM; Bradley WG; Jordan JE; Pema PJ; Goergen SK; Tam JK AJR Am J Roentgenol; 1995 May; 164(5):1213-21. PubMed ID: 7717234 [TBL] [Abstract][Full Text] [Related]
13. Fluid and white matter suppression with the MP2RAGE sequence. Tanner M; Gambarota G; Kober T; Krueger G; Erritzoe D; Marques JP; Newbould R J Magn Reson Imaging; 2012 May; 35(5):1063-70. PubMed ID: 22170818 [TBL] [Abstract][Full Text] [Related]
14. MR imaging of head and neck tumors: comparison of T1-weighted contrast-enhanced fat-suppressed images with conventional T2-weighted and fast spin-echo T2-weighted images. Ross MR; Schomer DF; Chappell P; Enzmann DR AJR Am J Roentgenol; 1994 Jul; 163(1):173-8. PubMed ID: 8010208 [TBL] [Abstract][Full Text] [Related]
15. Quantitation of galactosemic cataracts in dogs using magnetization transfer contrast-enhanced magnetic resonance imaging. Lizak MJ; Mori K; Ceckler TL; Balaban RS; Kador PF Invest Ophthalmol Vis Sci; 1996 Oct; 37(11):2219-27. PubMed ID: 8843908 [TBL] [Abstract][Full Text] [Related]
16. MP RAGE: a three-dimensional, T1-weighted, gradient-echo sequence--initial experience in the brain. Brant-Zawadzki M; Gillan GD; Nitz WR Radiology; 1992 Mar; 182(3):769-75. PubMed ID: 1535892 [TBL] [Abstract][Full Text] [Related]
17. [Parameter-weighted MR images and their optimization: theory and example of images for the flash sequence compared to the spin-echo sequence]. Kölbel G; Klose U; Hess CF; Küper K; Grodd W Rofo; 1988 Jun; 148(6):674-82. PubMed ID: 2837805 [TBL] [Abstract][Full Text] [Related]
18. MR imaging of peritoneal disease: comparison of contrast-enhanced fast multiplanar spoiled gradient-recalled and spin-echo imaging. Low RN; Sigeti JS AJR Am J Roentgenol; 1994 Nov; 163(5):1131-40. PubMed ID: 7976889 [TBL] [Abstract][Full Text] [Related]
19. Use of magnetization transfer contrast in gradient-recalled echo images. Dixon WT Radiology; 1991 Apr; 179(1):15-6. PubMed ID: 2006267 [No Abstract] [Full Text] [Related]
20. [Hyaline cartilage delineation of the knee joint using magnetization transfer contrast images]. Tamura A; Amanuma M; Hasegawa M; Enomoto K; Watabe T; Heshiki A Nihon Igaku Hoshasen Gakkai Zasshi; 1994 Jul; 54(8):801-3. PubMed ID: 8072872 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]