BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

210 related articles for article (PubMed ID: 20071271)

  • 1. Investigation of rotational skin stretch for proprioceptive feedback with application to myoelectric systems.
    Wheeler J; Bark K; Savall J; Cutkosky M
    IEEE Trans Neural Syst Rehabil Eng; 2010 Feb; 18(1):58-66. PubMed ID: 20071271
    [TBL] [Abstract][Full Text] [Related]  

  • 2. HapPro: A Wearable Haptic Device for Proprioceptive Feedback.
    Rossi M; Bianchi M; Battaglia E; Catalano MG; Bicchi A
    IEEE Trans Biomed Eng; 2019 Jan; 66(1):138-149. PubMed ID: 29993527
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A method to reversibly degrade proprioceptive feedback in research on human motor control.
    Bock O; Pipereit K; Mierau A
    J Neurosci Methods; 2007 Mar; 160(2):246-50. PubMed ID: 17092562
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Intelligent multifunction myoelectric control of hand prostheses.
    Light CM; Chappell PH; Hudgins B; Engelhart K
    J Med Eng Technol; 2002; 26(4):139-46. PubMed ID: 12396328
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Cineplasty as a control input for externally powered prosthetic components.
    Weir RF; Heckathorne CW; Childress DS
    J Rehabil Res Dev; 2001; 38(4):357-63. PubMed ID: 11563487
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A haptic feedback system for lower-limb prostheses.
    Fan RE; Culjat MO; King CH; Franco ML; Boryk R; Bisley JW; Dutson E; Grundfest WS
    IEEE Trans Neural Syst Rehabil Eng; 2008 Jun; 16(3):270-7. PubMed ID: 18586606
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Artificial proprioceptive feedback for myoelectric control.
    Pistohl T; Joshi D; Ganesh G; Jackson A; Nazarpour K
    IEEE Trans Neural Syst Rehabil Eng; 2015 May; 23(3):498-507. PubMed ID: 25216484
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Upper limb asymmetries in the matching of proprioceptive versus visual targets.
    Goble DJ; Brown SH
    J Neurophysiol; 2008 Jun; 99(6):3063-74. PubMed ID: 18436632
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Development of muscle fatigue as assessed by electromyography and mechanomyography during continuous and intermittent low-force contractions: effects of the feedback mode.
    Madeleine P; Jørgensen LV; Søgaard K; Arendt-Nielsen L; Sjøgaard G
    Eur J Appl Physiol; 2002 May; 87(1):28-37. PubMed ID: 12012073
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Multichannel Electrotactile Feedback With Spatial and Mixed Coding for Closed-Loop Control of Grasping Force in Hand Prostheses.
    Dosen S; Markovic M; Strbac M; Belic M; Kojic V; Bijelic G; Keller T; Farina D
    IEEE Trans Neural Syst Rehabil Eng; 2017 Mar; 25(3):183-195. PubMed ID: 27071179
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Portable haptic device for lower limb amputee gait feedback: Assessing static and dynamic perceptibility.
    Husman MAB; Maqbool HF; Awad MI; Dehghani-Sanij AA
    IEEE Int Conf Rehabil Robot; 2017 Jul; 2017():1562-1566. PubMed ID: 28814042
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Use of Magnetorheological fluid in a force feedback glove.
    Winter SH; Bouzit M
    IEEE Trans Neural Syst Rehabil Eng; 2007 Mar; 15(1):2-8. PubMed ID: 17436869
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Experimental development of a sensory control system for an upper limb myoelectric prosthesis with cosmetic covering.
    Tura A; Lamberti C; Davalli A; Sacchetti R
    J Rehabil Res Dev; 1998 Jan; 35(1):14-26. PubMed ID: 9505249
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A Portable Sensory Augmentation Device for Balance Rehabilitation Using Fingertip Skin Stretch Feedback.
    Pan YT; Yoon HU; Hur P
    IEEE Trans Neural Syst Rehabil Eng; 2017 Jan; 25(1):28-36. PubMed ID: 26992163
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Interaction of visual and proprioceptive feedback during adaptation of human reaching movements.
    Scheidt RA; Conditt MA; Secco EL; Mussa-Ivaldi FA
    J Neurophysiol; 2005 Jun; 93(6):3200-13. PubMed ID: 15659526
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A design of hardware haptic interface for gastrointestinal endoscopy simulation.
    Gu Y; Lee DY
    Stud Health Technol Inform; 2011; 163():199-201. PubMed ID: 21335788
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Force matching errors following eccentric exercise.
    Proske U; Gregory JE; Morgan DL; Percival P; Weerakkody NS; Canny BJ
    Hum Mov Sci; 2004 Oct; 23(3-4):365-78. PubMed ID: 15541523
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Kinematic and EMG characteristics of simple shoulder movements with proprioception and visual feedback.
    Brindle TJ; Nitz AJ; Uhl TL; Kifer E; Shapiro R
    J Electromyogr Kinesiol; 2006 Jun; 16(3):236-49. PubMed ID: 16111896
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Artificial proprioception for myoelectric control.
    Pistohl T; Jackson A; Gowrishankar G; Joshi D; Nazarpour K
    Annu Int Conf IEEE Eng Med Biol Soc; 2013; 2013():1595-8. PubMed ID: 24110007
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Advantages of externally powered prosthesis with feedback system using pseudo-cineplasty.
    Nambu S; Ikebuchi M; Taniguchi M; Park CS; Kitagawa T; Nakajima S; Koike T
    J Rehabil Res Dev; 2014; 51(7):1095-102. PubMed ID: 25436660
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.