248 related articles for article (PubMed ID: 20071765)
1. Development and verification of an analytical algorithm to predict absorbed dose distributions in ocular proton therapy using Monte Carlo simulations.
Koch NC; Newhauser WD
Phys Med Biol; 2010 Feb; 55(3):833-53. PubMed ID: 20071765
[TBL] [Abstract][Full Text] [Related]
2. Monte Carlo calculations and measurements of absorbed dose per monitor unit for the treatment of uveal melanoma with proton therapy.
Koch N; Newhauser WD; Titt U; Gombos D; Coombes K; Starkschall G
Phys Med Biol; 2008 Mar; 53(6):1581-94. PubMed ID: 18367789
[TBL] [Abstract][Full Text] [Related]
3. Monte Carlo simulations for configuring and testing an analytical proton dose-calculation algorithm.
Newhauser W; Fontenot J; Zheng Y; Polf J; Titt U; Koch N; Zhang X; Mohan R
Phys Med Biol; 2007 Aug; 52(15):4569-84. PubMed ID: 17634651
[TBL] [Abstract][Full Text] [Related]
4. Quantifying the effect of air gap, depth, and range shifter thickness on TPS dosimetric accuracy in superficial PBS proton therapy.
Shirey RJ; Wu HT
J Appl Clin Med Phys; 2018 Jan; 19(1):164-173. PubMed ID: 29239528
[TBL] [Abstract][Full Text] [Related]
5. Dosimetric evaluation of a commercial proton spot scanning Monte-Carlo dose algorithm: comparisons against measurements and simulations.
Saini J; Maes D; Egan A; Bowen SR; St James S; Janson M; Wong T; Bloch C
Phys Med Biol; 2017 Sep; 62(19):7659-7681. PubMed ID: 28749373
[TBL] [Abstract][Full Text] [Related]
6. Design and commissioning of the non-dedicated scanning proton beamline for ocular treatment at the synchrotron-based CNAO facility.
Ciocca M; Magro G; Mastella E; Mairani A; Mirandola A; Molinelli S; Russo S; Vai A; Fiore MR; Mosci C; Valvo F; Via R; Baroni G; Orecchia R
Med Phys; 2019 Apr; 46(4):1852-1862. PubMed ID: 30659616
[TBL] [Abstract][Full Text] [Related]
7. Validation and clinical implementation of an accurate Monte Carlo code for pencil beam scanning proton therapy.
Huang S; Kang M; Souris K; Ainsley C; Solberg TD; McDonough JE; Simone CB; Lin L
J Appl Clin Med Phys; 2018 Sep; 19(5):558-572. PubMed ID: 30058170
[TBL] [Abstract][Full Text] [Related]
8. Monte Carlo investigation of collimator scatter of proton-therapy beams produced using the passive scattering method.
Titt U; Zheng Y; Vassiliev ON; Newhauser WD
Phys Med Biol; 2008 Jan; 53(2):487-504. PubMed ID: 18185001
[TBL] [Abstract][Full Text] [Related]
9. An algorithm to assess the need for clinical Monte Carlo dose calculation for small proton therapy fields based on quantification of tissue heterogeneity.
Bueno M; Paganetti H; Duch MA; Schuemann J
Med Phys; 2013 Aug; 40(8):081704. PubMed ID: 23927301
[TBL] [Abstract][Full Text] [Related]
10. Accurate Monte Carlo simulations for nozzle design, commissioning and quality assurance for a proton radiation therapy facility.
Paganetti H; Jiang H; Lee SY; Kooy HM
Med Phys; 2004 Jul; 31(7):2107-18. PubMed ID: 15305464
[TBL] [Abstract][Full Text] [Related]
11. A pencil beam algorithm for magnetic resonance image-guided proton therapy.
Padilla-Cabal F; Georg D; Fuchs H
Med Phys; 2018 May; 45(5):2195-2204. PubMed ID: 29532490
[TBL] [Abstract][Full Text] [Related]
12. Development and benchmarking of the first fast Monte Carlo engine for helium ion beam dose calculation: MonteRay.
Lysakovski P; Besuglow J; Kopp B; Mein S; Tessonnier T; Ferrari A; Haberer T; Debus J; Mairani A
Med Phys; 2023 Apr; 50(4):2510-2524. PubMed ID: 36542403
[TBL] [Abstract][Full Text] [Related]
13. Independent dose verification system with Monte Carlo simulations using TOPAS for passive scattering proton therapy at the National Cancer Center in Korea.
Shin WG; Testa M; Kim HS; Jeong JH; Lee SB; Kim YJ; Min CH
Phys Med Biol; 2017 Sep; 62(19):7598-7616. PubMed ID: 28809759
[TBL] [Abstract][Full Text] [Related]
14. Study of the secondary neutral radiation in proton therapy: toward an indirect in vivo dosimetry.
Carnicer A; Letellier V; Rucka G; Angellier G; Sauerwein W; Herault J
Med Phys; 2012 Dec; 39(12):7303-16. PubMed ID: 23231280
[TBL] [Abstract][Full Text] [Related]
15. Commissioning and validation of a novel commercial TPS for ocular proton therapy.
Wulff J; Koska B; Heufelder J; Janson M; Bäcker CM; Siregar H; Behrends C; Bäumer C; Foerster A; Bechrakis NE; Timmermann B
Med Phys; 2023 Jan; 50(1):365-379. PubMed ID: 36195575
[TBL] [Abstract][Full Text] [Related]
16. Development and validation of MonteRay, a fast Monte Carlo dose engine for carbon ion beam radiotherapy.
Lysakovski P; Kopp B; Tessonnier T; Mein S; Ferrari A; Haberer T; Debus J; Mairani A
Med Phys; 2024 Feb; 51(2):1433-1449. PubMed ID: 37748042
[TBL] [Abstract][Full Text] [Related]
17. An analytical dose-averaged LET calculation algorithm considering the off-axis LET enhancement by secondary protons for spot-scanning proton therapy.
Hirayama S; Matsuura T; Ueda H; Fujii Y; Fujii T; Takao S; Miyamoto N; Shimizu S; Fujimoto R; Umegaki K; Shirato H
Med Phys; 2018 Jul; 45(7):3404-3416. PubMed ID: 29788552
[TBL] [Abstract][Full Text] [Related]
18. Monte Carlo and analytical calculation of proton pencil beams for computerized treatment plan optimization.
Carlsson AK; Andreo P; Brahme A
Phys Med Biol; 1997 Jun; 42(6):1033-53. PubMed ID: 9194127
[TBL] [Abstract][Full Text] [Related]
19. Monte Carlo simulations of a nozzle for the treatment of ocular tumours with high-energy proton beams.
Newhauser W; Koch N; Hummel S; Ziegler M; Titt U
Phys Med Biol; 2005 Nov; 50(22):5229-49. PubMed ID: 16264250
[TBL] [Abstract][Full Text] [Related]
20. Clinical Validation of a Ray-Casting Analytical Dose Engine for Spot Scanning Proton Delivery Systems.
Younkin JE; Morales DH; Shen J; Shan J; Bues M; Lentz JM; Schild SE; Stoker JB; Ding X; Liu W
Technol Cancer Res Treat; 2019; 18():1533033819887182. PubMed ID: 31755362
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]