These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

91 related articles for article (PubMed ID: 20073232)

  • 1. [Mock circulatory system for performance test of ventricular assist device].
    Lv XF; Yang M; Li JJ
    Zhongguo Yi Liao Qi Xie Za Zhi; 2009 Sep; 33(5):313-6. PubMed ID: 20073232
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A complete mock circulation loop for the evaluation of left, right, and biventricular assist devices.
    Timms D; Hayne M; McNeil K; Galbraith A
    Artif Organs; 2005 Jul; 29(7):564-72. PubMed ID: 15982285
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Minimal extracorporeal circulation circuit standby for "off-pump" left ventricular assist device implantation.
    Anastasiadis K; Westaby S; Antonitsis P; Argiriadou H; Karapanagiotidis G; Pigott D; Papakonstantinou C
    Artif Organs; 2010 Dec; 34(12):1156-8. PubMed ID: 20545669
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluation of left ventricular assist device performance and hydraulic force in a complete mock circulation loop.
    Timms D; Hayne M; Tan A; Pearcy M
    Artif Organs; 2005 Jul; 29(7):573-80. PubMed ID: 15982286
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Design and initial testing of a mock human circulatory loop for left ventricular assist device performance testing.
    Liu Y; Allaire P; Wood H; Olsen D
    Artif Organs; 2005 Apr; 29(4):341-5. PubMed ID: 15787631
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A new pulsatile volumetric device with biomorphic valves for the in vitro study of the cardiovascular system.
    Lanzarone E; Vismara R; Fiore GB
    Artif Organs; 2009 Dec; 33(12):1048-62. PubMed ID: 19604227
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Performance prediction of a percutaneous ventricular assist system using nonlinear circuit analysis techniques.
    Yu YC; Simaan MA; Mushi SE; Zorn NV
    IEEE Trans Biomed Eng; 2008 Feb; 55(2 Pt 1):419-29. PubMed ID: 18269977
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [A hardware-in-the-loop simulation model of the cardiovascular system for ventricular assist device evaluation].
    Honglei L; Ming Y; Shiyang L
    Zhongguo Yi Liao Qi Xie Za Zhi; 2010 Jan; 34(1):16-20. PubMed ID: 20391921
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Use of minimized extracorporeal circulation system in noncoronary and valve cardiac surgical procedures-a case series.
    Anastasiadis K; Chalvatzoulis O; Antonitsis P; Deliopoulos A; Argiriadou H; Karapanagiotidis G; Kambouroglou D; Papakonstantinou C
    Artif Organs; 2011 Oct; 35(10):960-3. PubMed ID: 21501191
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Control and testing methods for blood bump in heart assistant and replacement devices].
    Zhang T; Hu Z; Chen Z; Hou X
    Zhongguo Yi Liao Qi Xie Za Zhi; 2013 Nov; 37(6):432-6. PubMed ID: 24617215
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Cardiac extracorporeal life support: state of the art in 2007.
    Cooper DS; Jacobs JP; Moore L; Stock A; Gaynor JW; Chancy T; Parpard M; Griffin DA; Owens T; Checchia PA; Thiagarajan RR; Spray TL; Ravishankar C
    Cardiol Young; 2007 Sep; 17 Suppl 2():104-15. PubMed ID: 18039404
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Flow visualization techniques in a mock ventricle supported by a nonpulsatile left ventricular assist device.
    Khalil HA; Metcalfe RW; Kleis SJ; Lee EL; Gilbert NL; Kerr DT; Frazier OH; Cohn WE
    ASAIO J; 2009; 55(4):323-7. PubMed ID: 19512887
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A controller for a miniature intra-aortic ventricular assist device.
    Hsu PL; Bruch J; McMahon R
    Artif Organs; 2011 Mar; 35(3):282-7. PubMed ID: 21114678
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Mock circulatory system for the evaluation of left ventricular assist devices, endoluminal prostheses, and vascular diseases.
    Legendre D; Fonseca J; Andrade A; Biscegli JF; Manrique R; Guerrino D; Prakasan AK; Ortiz JP; Lucchi JC
    Artif Organs; 2008 Jun; 32(6):461-7. PubMed ID: 18422796
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A naturally shaped silicone ventricle evaluated in a mock circulation loop: a preliminary study.
    Gregory S; Timms D; Pearcy MJ; Tansley G
    J Med Eng Technol; 2009; 33(3):185-91. PubMed ID: 19340688
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Design of a small centrifugal blood pump with magnetic bearings.
    Jahanmir S; Hunsberger AZ; Ren Z; Heshmat H; Heshmat C; Tomaszewski MJ; Walton JF
    Artif Organs; 2009 Sep; 33(9):714-26. PubMed ID: 19775263
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Hemodynamic controller for left ventricular assist device based on pulsatility ratio.
    Choi S; Boston JR; Antaki JF
    Artif Organs; 2007 Feb; 31(2):114-25. PubMed ID: 17298400
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The CentriMag: a new optimized centrifugal blood pump with levitating impeller.
    Mueller JP; Kuenzli A; Reuthebuch O; Dasse K; Kent S; Zuend G; Turina MI; Lachat ML
    Heart Surg Forum; 2004; 7(5):E477-80. PubMed ID: 15802261
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Modeling, analysis, and validation of a pneumatically driven left ventricle for use in mock circulatory systems.
    Colacino FM; Arabia M; Moscato F; Danieli GA
    Med Eng Phys; 2007 Oct; 29(8):829-39. PubMed ID: 17055763
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Construction of an artificial heart pump performance test system.
    Liu Y; Allaire P; Wu Y; Wood H; Olsen D
    Cardiovasc Eng; 2006 Dec; 6(4):151-8. PubMed ID: 17136597
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.