These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

84 related articles for article (PubMed ID: 20076137)

  • 1. The efficient use of photomultiplier tubes for recording spectra.
    Rolfe J; Moore SE
    Appl Opt; 1970 Jan; 9(1):63-71. PubMed ID: 20076137
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Synchronous Detection vs Pulse Counting for Sensitive Photomultiplier Detection Systems.
    Nakamura JK; Schwarz SE
    Appl Opt; 1968 Jun; 7(6):1073-8. PubMed ID: 20068742
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Noise in the measurement of light with photomultipliers.
    Robben F
    Appl Opt; 1971 Apr; 10(4):776-96. PubMed ID: 20094540
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluation of magnetic defocusing for a photomultiplier tube with large area semitransparent photocathode.
    Knight W; Kohanzadeh Y; Lengyel G
    Appl Opt; 1968 Jun; 7(6):1115-20. PubMed ID: 20068748
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The use of photomultiplier tubes for photon counting.
    Foord R; Jones R; Oliver CJ; Pike ER
    Appl Opt; 1969 Oct; 8(10):1975-89. PubMed ID: 20072559
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A practical multiple reflection technique for improving the quantum efficiency of photomultiplier tubes.
    Oke JB; Schild RE
    Appl Opt; 1968 Apr; 7(4):617-22. PubMed ID: 20068647
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of photomultiplier and si photodiode as detectors in radiation pyrometry.
    Ruffino G
    Appl Opt; 1971 Jun; 10(6):1241-5. PubMed ID: 20111102
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Photometric Error Analysis. IX: Optimum Use of Photomultipliers.
    Young AT
    Appl Opt; 1969 Dec; 8(12):2431-47. PubMed ID: 20076054
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Instability of photomultiplier tubes and consequences for accuracy of radioactivity measurements.
    van Duyl WA; de Kruijk A
    Med Prog Technol; 1978 Nov; 6(1):29-34. PubMed ID: 732791
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Pulse-height measurements with a cooled avalanche-photodiode detector.
    Kishimoto S
    J Synchrotron Radiat; 1998 May; 5(Pt 3):883-5. PubMed ID: 15263685
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Experimental and theoretical comparison of photon-counting and current measurements of light intensity.
    Jones R; Oliver CJ; Pike ER
    Appl Opt; 1971 Jul; 10(7):1673-80. PubMed ID: 20111185
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Gated photomultiplier response characterization for DIAL measurements.
    Lee HS; Schwemmer GK; Korb CL; Dombrowski M; Prasad C
    Appl Opt; 1990 Aug; 29(22):3303-15. PubMed ID: 20567413
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Anomalous gain changes in photomultiplier tubes for use in scintillation counting.
    Yamashita M
    Rev Sci Instrum; 1978 Apr; 49(4):499. PubMed ID: 18699133
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Cardiac peptide stability, aprotinin and room temperature: importance for assessing cardiac function in clinical practice.
    Buckley MG; Marcus NJ; Yacoub MH
    Clin Sci (Lond); 1999 Dec; 97(6):689-95. PubMed ID: 10585896
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Pulsed-source time-resolved phosphorimetry: comparison of a commercial gated photomultiplier with a specially wired ungated photomultiplier.
    Persvik Ø; Melø TB; Naqvi KR
    Photochem Photobiol Sci; 2013 Jun; 12(6):1110-3. PubMed ID: 23503741
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Depolarization ratio measurement using single photomultiplier tube in micropulse lidar.
    Dubey PK; Jain SL; Arya BC; Kulkarni PS
    Rev Sci Instrum; 2009 May; 80(5):053111. PubMed ID: 19485496
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Temperature dependence of spurious pulses in use of plastic scintillation detectors.
    Kawada Y; Ito J; Wang QW
    Appl Radiat Isot; 2004; 60(2-4):403-7. PubMed ID: 14987675
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of standard polyvinyl chloride tracheal tubes and straight reinforced tracheal tubes for tracheal intubation through different sizes of the Airtraq laryngoscope in anesthetized and paralyzed patients: a randomized prospective study.
    Dimitriou VK; Zogogiannis ID; Douma AK; Pentilas ND; Liotiri DG; Wachtel MS; Karakitsos D
    Anesthesiology; 2009 Dec; 111(6):1265-70. PubMed ID: 19934870
    [TBL] [Abstract][Full Text] [Related]  

  • 19. New developments in multiplier phototubes for space research.
    Rome M
    Appl Opt; 1966 May; 5(5):855-61. PubMed ID: 20048960
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Avalanche photodiode based detector for beam emission spectroscopy.
    Dunai D; Zoletnik S; Sárközi J; Field AR
    Rev Sci Instrum; 2010 Oct; 81(10):103503. PubMed ID: 21034087
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.