173 related articles for article (PubMed ID: 20077073)
1. High sensitivity measurement of estrone and estradiol in serum and plasma using LC-MS/MS.
Kushnir MM; Rockwood AL; Yue B; Meikle AW
Methods Mol Biol; 2010; 603():219-28. PubMed ID: 20077073
[TBL] [Abstract][Full Text] [Related]
2. High-sensitivity tandem mass spectrometry assay for serum estrone and estradiol.
Kushnir MM; Rockwood AL; Bergquist J; Varshavsky M; Roberts WL; Yue B; Bunker AM; Meikle AW
Am J Clin Pathol; 2008 Apr; 129(4):530-9. PubMed ID: 18343779
[TBL] [Abstract][Full Text] [Related]
3. Highly sensitive determination of estrone and estradiol in human serum by liquid chromatography-electrospray ionization tandem mass spectrometry.
Yamashita K; Okuyama M; Watanabe Y; Honma S; Kobayashi S; Numazawa M
Steroids; 2007 Oct; 72(11-12):819-27. PubMed ID: 17716700
[TBL] [Abstract][Full Text] [Related]
4. Derivatization of estrogens enhances specificity and sensitivity of analysis of human plasma and serum by liquid chromatography tandem mass spectrometry.
Faqehi AMM; Cobice DF; Naredo G; Mak TCS; Upreti R; Gibb FW; Beckett GJ; Walker BR; Homer NZM; Andrew R
Talanta; 2016 May; 151():148-156. PubMed ID: 26946022
[TBL] [Abstract][Full Text] [Related]
5. Serum testosterone levels measured by isotope dilution-liquid chromatography-tandem mass spectrometry in postmenopausal women versus those in women who underwent bilateral oophorectomy.
Bui HN; Struys EA; Martens F; de Ronde W; Thienpont LM; Kenemans P; Verhoeven MO; Jakobs C; Dijstelbloem HM; Blankenstein MA
Ann Clin Biochem; 2010 May; 47(Pt 3):248-52. PubMed ID: 20406776
[TBL] [Abstract][Full Text] [Related]
6. LC-MS/MS coupled with immunoaffinity extraction for determination of estrone, 17beta-estradiol and estrone 3-sulfate in human plasma.
Hosogi J; Tanaka H; Fujita K; Kuwabara T; Ikegawa S; Kobayashi N; Mano N; Goto J
J Chromatogr B Analyt Technol Biomed Life Sci; 2010 Jan; 878(2):222-7. PubMed ID: 19700374
[TBL] [Abstract][Full Text] [Related]
7. Column-switching reversed phase-hydrophilic interaction liquid chromatography/tandem mass spectrometry method for determination of free estrogens and their conjugates in river water.
Qin F; Zhao YY; Sawyer MB; Li XF
Anal Chim Acta; 2008 Oct; 627(1):91-8. PubMed ID: 18790131
[TBL] [Abstract][Full Text] [Related]
8. Comparison of electrospray ionization, atmospheric pressure chemical ionization and atmospheric pressure photoionization for determining estrogenic chemicals in water by liquid chromatography tandem mass spectrometry with chemical derivatizations.
Lien GW; Chen CY; Wang GS
J Chromatogr A; 2009 Feb; 1216(6):956-66. PubMed ID: 19118834
[TBL] [Abstract][Full Text] [Related]
9. Development and evaluation of a reference measurement procedure for the determination of estradiol-17beta in human serum using isotope-dilution liquid chromatography-tandem mass spectrometry.
Tai SS; Welch MJ
Anal Chem; 2005 Oct; 77(19):6359-63. PubMed ID: 16194100
[TBL] [Abstract][Full Text] [Related]
10. Determination of testosterone in serum by liquid chromatography-tandem mass spectrometry.
Turpeinen U; Linko S; Itkonen O; Hämäläinen E
Scand J Clin Lab Invest; 2008; 68(1):50-7. PubMed ID: 17852804
[TBL] [Abstract][Full Text] [Related]
11. Comparative study of an estradiol enzyme-linked immunosorbent assay kit, liquid chromatography-tandem mass spectrometry, and ultra performance liquid chromatography-quadrupole time of flight mass spectrometry for part-per-trillion analysis of estrogens in water samples.
Farré M; Kuster M; Brix R; Rubio F; López de Alda MJ; Barceló D
J Chromatogr A; 2007 Aug; 1160(1-2):166-75. PubMed ID: 17540393
[TBL] [Abstract][Full Text] [Related]
12. Determination of natural and synthetic estrogens and their conjugates in sewage sludge by pressurized liquid extraction and liquid chromatography-tandem mass spectrometry.
Nieto A; Borrull F; Pocurull E; Marcé RM
J Chromatogr A; 2008 Dec; 1213(2):224-30. PubMed ID: 18976768
[TBL] [Abstract][Full Text] [Related]
13. Direct measurement of free estradiol in human serum by equilibrium dialysis-liquid chromatography-tandem mass spectrometry and reference intervals of free estradiol in women.
Ray JA; Kushnir MM; Bunker A; Rockwood AL; Meikle AW
Clin Chim Acta; 2012 Jun; 413(11-12):1008-14. PubMed ID: 22421268
[TBL] [Abstract][Full Text] [Related]
14. Simultaneous determination of a selective adenosine 2A agonist, BMS-068645, and its acid metabolite in human plasma by liquid chromatography-tandem mass spectrometry--evaluation of the esterase inhibitor, diisopropyl fluorophosphate, in the stabilization of a labile ester-containing drug.
Zeng J; Onthank D; Crane P; Unger S; Zheng N; Pasas-Farmer S; Arnold M
J Chromatogr B Analyt Technol Biomed Life Sci; 2007 Jun; 852(1-2):77-84. PubMed ID: 17280881
[TBL] [Abstract][Full Text] [Related]
15. Simultaneous quantitation of endogenous estrone, 17β-estradiol, and estriol in human serum by isotope-dilution liquid chromatography-tandem mass spectrometry for clinical laboratory applications.
Zhang Q; Han L; Wang J; Lin H; Ke P; Zhuang J; Huang X
Anal Bioanal Chem; 2017 Apr; 409(10):2627-2638. PubMed ID: 28224243
[TBL] [Abstract][Full Text] [Related]
16. Development and validation of a high-sensitivity liquid chromatography/tandem mass spectrometry (LC/MS/MS) method with chemical derivatization for the determination of ethinyl estradiol in human plasma.
Shou WZ; Jiang X; Naidong W
Biomed Chromatogr; 2004 Sep; 18(7):414-21. PubMed ID: 15340965
[TBL] [Abstract][Full Text] [Related]
17. Quantitation of nicotine, its metabolites, and other related alkaloids in urine, serum, and plasma using LC-MS-MS.
Yue B; Kushnir MM; Urry FM; Rockwood AL
Methods Mol Biol; 2010; 603():389-98. PubMed ID: 20077091
[TBL] [Abstract][Full Text] [Related]
18. Determination of aldosterone in serum by liquid chromatography-tandem mass spectrometry.
Turpeinen U; Hämäläinen E; Stenman UH
J Chromatogr B Analyt Technol Biomed Life Sci; 2008 Feb; 862(1-2):113-8. PubMed ID: 18054292
[TBL] [Abstract][Full Text] [Related]
19. Development of a highly sensitive method for the quantification of estrone and estradiol in serum by liquid chromatography tandem mass spectrometry without derivatization.
Fiers T; Casetta B; Bernaert B; Vandersypt E; Debock M; Kaufman JM
J Chromatogr B Analyt Technol Biomed Life Sci; 2012 Apr; 893-894():57-62. PubMed ID: 22429877
[TBL] [Abstract][Full Text] [Related]
20. An improved high-throughput liquid chromatographic/tandem mass spectrometric method for terbinafine quantification in human plasma, using automated liquid-liquid extraction based on 96-well format plates.
Dotsikas Y; Apostolou C; Kousoulos C; Tsatsou G; Loukas YL
Biomed Chromatogr; 2007 Feb; 21(2):201-8. PubMed ID: 17221909
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]