These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

90 related articles for article (PubMed ID: 20078272)

  • 1. Thoraco-abdominal perimetry for partitioning of the tidal volume into fractions due to rib cage expansion and diaphragmatic descent.
    Jakobson S; Ivarsson I
    Ups J Med Sci; 1977; 82(1):31-7. PubMed ID: 20078272
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Accuracy of respiratory inductive plethysmograph over wide range of rib cage and abdominal compartmental contributions to tidal volume in normal subjects and in patients with chronic obstructive pulmonary disease.
    Gonzalez H; Haller B; Watson HL; Sackner MA
    Am Rev Respir Dis; 1984 Aug; 130(2):171-4. PubMed ID: 6465670
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Rib cage and abdominal volume displacements during breathing in pregnancy.
    Gilroy RJ; Mangura BT; Lavietes MH
    Am Rev Respir Dis; 1988 Mar; 137(3):668-72. PubMed ID: 3345045
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Thoracic gas volume and chest-abdomen dimensions during anesthesia and muscle paralysis.
    Hedenstierna G; Löfström B; Lundh R
    Anesthesiology; 1981 Nov; 55(5):499-506. PubMed ID: 7294403
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Calibration of respiratory inductive plethysmography during quiet and active sleep in lambs.
    Warren RH; Fewell JE; Alderson SH
    J Dev Physiol; 1989 Dec; 12(6):347-52. PubMed ID: 2640229
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Occlusion maneuver to detect the relative contribution of the rib cage and abdomen to tidal volume using respiratory inductive plethysmography in infants.
    Gagliardi L; Rusconi F; Aston H; Silverman M
    Pediatr Pulmonol; 1996 Feb; 21(2):132-7. PubMed ID: 8882215
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Thoracic epidural anesthesia increases diaphragmatic shortening after thoracotomy in the awake lamb.
    Polaner DM; Kimball WR; Fratacci MD; Wain JC; Zapol WM
    Anesthesiology; 1993 Oct; 79(4):808-16. PubMed ID: 8214761
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Postural changes in rib cage and abdominal volume-motion coefficients and their effect on the calibration of a respiratory inductance plethysmograph.
    Zimmerman PV; Connellan SJ; Middleton HC; Tabona MV; Goldman MD; Pride N
    Am Rev Respir Dis; 1983 Feb; 127(2):209-14. PubMed ID: 6830037
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Relationships between abdominal and diaphragmatic volume displacements.
    Knight H; Petroll WM; Rochester DF
    J Appl Physiol (1985); 1991 Aug; 71(2):565-72. PubMed ID: 1938730
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Respiratory inductance plethysmography: calibration techniques, their validation and the effects of posture.
    Stradling JR; Chadwick GA; Quirk C; Phillips T
    Bull Eur Physiopathol Respir; 1985; 21(4):317-24. PubMed ID: 4041657
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Chest wall mechanics during pressure support ventilation.
    Aliverti A; Carlesso E; Dellacà R; Pelosi P; Chiumello D; Pedotti A; Gattinoni L
    Crit Care; 2006; 10(2):R54. PubMed ID: 16584534
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Relative contributions of rib cage and abdomen to breathing in normal subjects.
    Sharp JT; Goldberg NB; Druz WS; Danon J
    J Appl Physiol; 1975 Oct; 39(4):608-18. PubMed ID: 1194152
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The effect of breath size and posture on calibration of the respiratory inductive plethysmograph by multiple linear regression.
    Verschakelen JA; Deschepper K; Clarysse I; Demedts M
    Eur Respir J; 1989 Jan; 2(1):71-7. PubMed ID: 2707404
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The effect of carbon dioxide inhalation on phase characteristics of breathing movements in healthy newborn infants.
    Andersson D; Gennser G; Johnson P
    J Dev Physiol; 1986 Jun; 8(3):147-57. PubMed ID: 3091674
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Relationship between diaphragm length and abdominal dimensions.
    Decramer M; Xi JT; Reid MB; Kelly S; Macklem PT; Demedts M
    J Appl Physiol (1985); 1986 Nov; 61(5):1815-20. PubMed ID: 3781990
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Thoraco-abdominal asymmetry and asynchrony in congenital diaphragmatic hernia.
    Laviola M; Zanini A; Priori R; Macchini F; Leva E; Torricelli M; Ceruti C; Aliverti A
    Pediatr Pulmonol; 2015 Sep; 50(9):915-24. PubMed ID: 25052453
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Action of respiratory muscles during exercise as inferred from rib-cage and abdominal pressure-volume partitioning.
    Mead J; Goldman M; Grimby G
    Scand J Respir Dis Suppl; 1971; 77():8-13. PubMed ID: 5288496
    [No Abstract]   [Full Text] [Related]  

  • 18. Comparison of thoracoabdominal calibration methods in normal human subjects.
    Sartene R; Dartus C; Bernard JL; Mathieu M; Goldman MD
    J Appl Physiol (1985); 1993 Nov; 75(5):2142-50. PubMed ID: 8307871
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Chest wall kinematics, respiratory muscle action and dyspnoea during arm vs. leg exercise in humans.
    Romagnoli I; Gorini M; Gigliotti F; Bianchi R; Lanini B; Grazzini M; Stendardi L; Scano G
    Acta Physiol (Oxf); 2006 Sep; 188(1):63-73. PubMed ID: 16911254
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Analysis of volume displacement and length changes of the diaphragm during breathing.
    Mead J; Loring SH
    J Appl Physiol Respir Environ Exerc Physiol; 1982 Sep; 53(3):750-5. PubMed ID: 6215387
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.