BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

100 related articles for article (PubMed ID: 2007883)

  • 1. Evaluation of immunoassay methods for the screening of cocaine metabolites in urine.
    Baugh LD; Allen EE; Liu RH; Langner JG; Fentress JC; Chadha SC; Cook LF; Walia AS
    J Forensic Sci; 1991 Jan; 36(1):79-85. PubMed ID: 2007883
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A comparison of ONTRAK TESTCUP, abuscreen ONTRAK, abuscreen ONLINE, and GC/MS urinalysis test results.
    Crouch DJ; Cheever ML; Andrenyak DM; Kuntz DJ; Loughmiller DL
    J Forensic Sci; 1998 Jan; 43(1):35-40. PubMed ID: 9456522
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Validity testing of commercial urine cocaine metabolite assays: III. Evaluation of an enzyme-linked immunosorbent assay (ELISA) for detection of cocaine and cocaine metabolite.
    Cone EJ
    J Forensic Sci; 1989 Jul; 34(4):991-5. PubMed ID: 2760594
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Concentration profiles of cocaine, pyrolytic methyl ecgonidine and thirteen metabolites in human blood and urine: determination by gas chromatography-mass spectrometry.
    Paul BD; Lalani S; Bosy T; Jacobs AJ; Huestis MA
    Biomed Chromatogr; 2005 Nov; 19(9):677-88. PubMed ID: 15841503
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Validity testing of commercial urine cocaine metabolite assays: IV. Evaluation of the EMIT d.a.u. cocaine metabolite assay in a quantitative mode for detection of cocaine metabolite.
    Cone EJ; Yousefnejad D; Dickerson SL
    J Forensic Sci; 1990 Jul; 35(4):786-91. PubMed ID: 2202774
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Determination of opiates and cocaine in hair using automated enzyme immunoassay screening methodologies followed by gas chromatographic-mass spectrometric (GC-MS) confirmation.
    Lachenmeier K; Musshoff F; Madea B
    Forensic Sci Int; 2006 Jun; 159(2-3):189-99. PubMed ID: 16203118
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Validity testing of commercial urine cocaine metabolite assays: I. Assay detection times, individual excretion patterns, and kinetics after cocaine administration to humans.
    Cone EJ; Menchen SL; Paul BD; Mell LD; Mitchell J
    J Forensic Sci; 1989 Jan; 34(1):15-31. PubMed ID: 2918277
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Correlations on radioimmunoassay, fluorescence polarization immunoassay, and enzyme immunoassay of cannabis metabolites with gas chromatography/mass spectrometry analysis of 11-nor-delta 9-tetrahydrocannabinol-9-carboxylic acid in urine specimens.
    Weaver ML; Gan BK; Allen E; Baugh LD; Liao FY; Liu RH; Langner JG; Walia AS; Cook LF
    Forensic Sci Int; 1991; 49(1):43-56. PubMed ID: 1851715
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Precision and comparability of Abuscreen OnLine assays for drugs of abuse screening in urine on Hitachi 917 with other immunochemical tests and with GC/MS.
    Boettcher M; Haenseler E; Hoke C; Nichols J; Raab D; Domke I
    Clin Lab; 2000; 46(1-2):49-52. PubMed ID: 10745981
    [TBL] [Abstract][Full Text] [Related]  

  • 10. On-site screening and GC-MS analysis of cocaine and heroin metabolites in body-packers urine.
    Marchei E; Colone P; Nastasi GG; CalabrĂ² C; Pellegrini M; Pacifici R; Zuccaro P; Pichini S
    J Pharm Biomed Anal; 2008 Sep; 48(2):383-7. PubMed ID: 18164159
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation of ephedrine, pseudoephedrine and phenylpropanolamine concentrations in human urine samples and a comparison of the specificity of DRI amphetamines and Abuscreen online (KIMS) amphetamines screening immunoassays.
    Stout PR; Klette KL; Horn CK
    J Forensic Sci; 2004 Jan; 49(1):160-4. PubMed ID: 14979364
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Elimination of fluconazole interference in gas chromatography/mass spectrometric confirmation of benzoylecgonine, the major metabolite of cocaine using pentafluoropropionyl derivative.
    Dasgupta A; Mahle C; McLemore J
    J Forensic Sci; 1996 May; 41(3):511-3. PubMed ID: 8656195
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of fluorescence polarization immunoassay, enzyme immunoassay, and thin-layer chromatography for urine cannabinoid screening. Effects of analyte adsorption and vigorous mixing of specimen on detectability.
    Dextraze P; Griffiths WC; Camara P; Audette L; Rosner M
    Ann Clin Lab Sci; 1989; 19(2):133-8. PubMed ID: 2546480
    [TBL] [Abstract][Full Text] [Related]  

  • 14. An automated preconcentration-derivatization system for the determination of cocaine and its metabolites in urine and illicit cocaine samples by gas chromatography/mass spectrometry.
    Cardenas S; Gallego M; Valcarcel M
    Rapid Commun Mass Spectrom; 1996; 10(6):631-6. PubMed ID: 8624416
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Screening for cocaine metabolite fails to detect an intoxication.
    Baker JE; Jenkins AJ
    Am J Forensic Med Pathol; 2008 Jun; 29(2):141-4. PubMed ID: 18520481
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Urine testing for cocaine abuse: metabolic and excretion patterns following different routes of administration and methods for detection of false-negative results.
    Cone EJ; Sampson-Cone AH; Darwin WD; Huestis MA; Oyler JM
    J Anal Toxicol; 2003 Oct; 27(7):386-401. PubMed ID: 14606991
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Benzoylecgonine and ecgonine methyl ester concentrations in urine specimens.
    Ramcharitar V; Levine B; Smialek JE
    J Forensic Sci; 1995 Jan; 40(1):99-101. PubMed ID: 7876811
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Measurement of cocaine and metabolites in urine, meconium, and diapers by gas chromatography/mass spectrometry.
    Lombardero N; Casanova O; Behnke M; Eyler FD; Bertholf RL
    Ann Clin Lab Sci; 1993; 23(5):385-94. PubMed ID: 8239486
    [TBL] [Abstract][Full Text] [Related]  

  • 19. GC/MS quantitation of benzoylecgonine following liquid-liquid extraction of urine.
    Gerlits J
    J Forensic Sci; 1993 Sep; 38(5):1210-4. PubMed ID: 8228889
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Modification of screening immunoassays to detect sub-threshold concentrations of cocaine, cannabinoids, and opiates in urine: use for detecting maternal and neonatal drug exposures.
    Hattab EM; Goldberger BA; Johannsen LM; Kindland PW; Ticino F; Chronister CW; Bertholf RL
    Ann Clin Lab Sci; 2000 Jan; 30(1):85-91. PubMed ID: 10678589
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.