127 related articles for article (PubMed ID: 20083286)
1. A novel method using the VIO soft-coagulation system for liver resection.
Hirokawa F; Hayashi M; Miyamoto Y; Iwamoto M; Tsunematsu I; Asakuma M; Shimizu T; Komeda K; Inoue Y; Tanigawa N
Surgery; 2011 Mar; 149(3):438-44. PubMed ID: 20083286
[TBL] [Abstract][Full Text] [Related]
2. Liver resection using a soft-coagulation system without the Pringle maneuver.
Okamoto K; Koyama I; Toshimitsu Y; Aikawa M; Okada K; Ueno Y; Miyazawa M
Hepatogastroenterology; 2012 May; 59(115):875-7. PubMed ID: 22024227
[TBL] [Abstract][Full Text] [Related]
3. Impact of the VIO system in hepatic resection for patients with hepatocellular carcinoma.
Itoh S; Fukuzawa K; Shitomi Y; Okamoto M; Kinoshita T; Taketomi A; Shirabe K; Wakasugi K; Maehara Y
Surg Today; 2012 Dec; 42(12):1176-82. PubMed ID: 22993104
[TBL] [Abstract][Full Text] [Related]
4. Tissue preserving hepatectomy by a vessel sealing device.
Tepetes K; Christodoulidis G; Spyridakis EM; Chatzitheofilou C
J Surg Oncol; 2008 Feb; 97(2):165-8. PubMed ID: 17786962
[TBL] [Abstract][Full Text] [Related]
5. The vessel sealing system (LigaSure) in hepatic resection: a randomized controlled trial.
Ikeda M; Hasegawa K; Sano K; Imamura H; Beck Y; Sugawara Y; Kokudo N; Makuuchi M
Ann Surg; 2009 Aug; 250(2):199-203. PubMed ID: 19638927
[TBL] [Abstract][Full Text] [Related]
6. Cavitron Ultrasonic Surgical Aspirator (CUSA) in liver resection.
Fasulo F; Giori A; Fissi S; Bozzetti F; Doci R; Gennari L
Int Surg; 1992; 77(1):64-6. PubMed ID: 1577582
[TBL] [Abstract][Full Text] [Related]
7. Bipolar vessel sealing system vs. clamp crushing technique for liver parenchyma transection.
Garancini M; Gianotti L; Mattavelli I; Romano F; Degrate L; Caprotti R; Nespoli A; Uggeri F
Hepatogastroenterology; 2011; 58(105):127-32. PubMed ID: 21510299
[TBL] [Abstract][Full Text] [Related]
8. Gyrus PlasmaKinetic bipolar coagulation device for liver resection.
Tan J; Hunt A; Wijesuriya R; Delriviere L; Mitchell A
ANZ J Surg; 2010 Mar; 80(3):182-5. PubMed ID: 20575923
[TBL] [Abstract][Full Text] [Related]
9. Efficacy of SOFT COAG for intraoperative bleeding in thoracic surgery.
Sakuragi T; Ohma H; Ohteki H
Interact Cardiovasc Thorac Surg; 2009 Nov; 9(5):767-8. PubMed ID: 19713242
[TBL] [Abstract][Full Text] [Related]
10. Usefulness of the combination procedure of crash clamping and vessel sealing for hepatic resection.
Nanashima A; Tobinaga S; Abo T; Nonaka T; Sawai T; Nagayasu T
J Surg Oncol; 2010 Aug; 102(2):179-83. PubMed ID: 20648591
[TBL] [Abstract][Full Text] [Related]
11. Two-surgeon technique for liver transection using precoagulation by a soft-coagulation system and ultrasonic dissection.
Yamada N; Amano R; Kimura K; Murata A; Yashiro M; Tanaka S; Wakasa K; Hirakawa K
Hepatogastroenterology; 2015; 62(138):389-92. PubMed ID: 25916069
[TBL] [Abstract][Full Text] [Related]
12. Usefulness of LigaSure for liver resection: analysis by randomized clinical trial.
Saiura A; Yamamoto J; Koga R; Sakamoto Y; Kokudo N; Seki M; Yamaguchi T; Yamaguchi T; Muto T; Makuuchi M
Am J Surg; 2006 Jul; 192(1):41-5. PubMed ID: 16769273
[TBL] [Abstract][Full Text] [Related]
13. Significance of a soft-coagulation system with monopolar electrode for hepatectomy: A retrospective two-institution study by propensity analysis.
Hamada T; Nanashima A; Yano K; Sumida Y; Hiyoshi M; Imamura N; Tobinaga S; Tsuchimochi Y; Takeno S; Fujii Y; Nagayasu T
Int J Surg; 2017 Sep; 45():149-155. PubMed ID: 28774659
[TBL] [Abstract][Full Text] [Related]
14. [Liver resection with the water jet: conventional and laparoscopic surgery].
Rau HG; Meyer G; Jauch KW; Cohnert TU; Buttler E; Schildberg FW
Chirurg; 1996 May; 67(5):546-51. PubMed ID: 8777886
[TBL] [Abstract][Full Text] [Related]
15. No silver bullet in liver transection: what has 35 years of new technology added to liver surgery?
Chapman WC
Ann Surg; 2009 Aug; 250(2):204-5. PubMed ID: 19638900
[No Abstract] [Full Text] [Related]
16. Randomized clinical trial of radiofrequency-assisted versus clamp-crushing liver resection.
Lupo L; Gallerani A; Panzera P; Tandoi F; Di Palma G; Memeo V
Br J Surg; 2007 Mar; 94(3):287-91. PubMed ID: 17318804
[TBL] [Abstract][Full Text] [Related]
17. The superficial precoagulation, sealing, and transection method: a "bloodless" and "ecofriendly" laparoscopic liver transection technique.
Itano O; Ikoma N; Takei H; Oshima G; Kitagawa Y
Surg Laparosc Endosc Percutan Tech; 2015 Feb; 25(1):e33-e36. PubMed ID: 24752166
[TBL] [Abstract][Full Text] [Related]
18. [Radio-frequency ablation appliance in resection of the liver].
Fedorov VD; Vishnevskiĭ VA; Kubyshkin VA; Korniak BS; Ikramov RZ; Gavrilin AV; Shchegolev AI; Sergeeva ON; Ionkin DA; Tarasiuk TI
Khirurgiia (Mosk); 2004; (5):21-5. PubMed ID: 15159755
[TBL] [Abstract][Full Text] [Related]
19. A new single-instrument technique for parenchyma division and hemostasis in liver resection: a clinical feasibility study.
Burdío F; Grande L; Berjano E; Martinez-Serrano M; Poves I; Burdío JM; Navarro A; Güemes A
Am J Surg; 2010 Dec; 200(6):e75-80. PubMed ID: 20864082
[TBL] [Abstract][Full Text] [Related]
20. Use of an electrothermal bipolar vessel sealing device during recipient hepatectomy for liver transplantation.
Houben P; Büchler MW; Schemmer P
J Am Coll Surg; 2014 Nov; 219(5):e59-63. PubMed ID: 25260682
[No Abstract] [Full Text] [Related]
[Next] [New Search]