41 related articles for article (PubMed ID: 20083291)
1. A novel power spectrum calculation method using phase-compensation and weighted averaging for the estimation of ultrasound attenuation.
Heo SW; Kim H
Ultrasonics; 2010 May; 50(6):592-9. PubMed ID: 20083291
[TBL] [Abstract][Full Text] [Related]
2. Improving the statistics of quantitative ultrasound techniques with deformation compounding: an experimental study.
Herd MT; Hall TJ; Jiang J; Zagzebski JA
Ultrasound Med Biol; 2011 Dec; 37(12):2066-74. PubMed ID: 22033132
[TBL] [Abstract][Full Text] [Related]
3. Time domain attenuation estimation method from ultrasonic backscattered signals.
Ghoshal G; Oelze ML
J Acoust Soc Am; 2012 Jul; 132(1):533-43. PubMed ID: 22779499
[TBL] [Abstract][Full Text] [Related]
4. Lower Bound on Estimation Variance of the Ultrasonic Attenuation Coefficient Using the Spectral-Difference Reference-phantom Method.
Samimi K; Varghese T
Ultrason Imaging; 2017 May; 39(3):151-171. PubMed ID: 28425388
[TBL] [Abstract][Full Text] [Related]
5. Noise Suppression for Ultrasound Attenuation Coefficient Estimation Based on Spectrum Normalization.
Gong P; Song P; Huang C; Lok UW; Tang S; Zhou C; Yang L; Watt KD; Callstrom M; Chen S
IEEE Trans Ultrason Ferroelectr Freq Control; 2021 Aug; 68(8):2667-2674. PubMed ID: 33877970
[TBL] [Abstract][Full Text] [Related]
6. Regularized Estimation of Effective Scatterer Size and Acoustic Concentration Quantitative Ultrasound Parameters Using Dynamic Programming
Jafarpisheh N; Rosado-Mendez IM; Hall TJ; Rivaz H
Annu Int Conf IEEE Eng Med Biol Soc; 2020 Jul; 2020():13-16. PubMed ID: 33017919
[TBL] [Abstract][Full Text] [Related]
7. Fine-tuning the H-scan for discriminating changes in tissue scatterers.
Parker KJ; Baek J
Biomed Phys Eng Express; 2020 May; 6(4):045012. PubMed ID: 33444273
[TBL] [Abstract][Full Text] [Related]
8. Spectral-based Quantitative Ultrasound Imaging Processing Techniques: Comparisons of RF Versus IQ Approaches.
Liu M; Kou Z; Zhao Y; Wiskin JW; Czarnota GJ; Oelze ML
Ultrason Imaging; 2024 Mar; 46(2):75-89. PubMed ID: 38318705
[TBL] [Abstract][Full Text] [Related]
9. Mean scatterer spacing estimation in normal and thermally coagulated ex vivo bovine liver.
Rubert N; Varghese T
Ultrason Imaging; 2014 Apr; 36(2):79-97. PubMed ID: 24554290
[TBL] [Abstract][Full Text] [Related]
10. Homodyned K-Distribution Parameter Estimation in Quantitative Ultrasound: Autoencoder and Bayesian Neural Network Approaches.
Tehrani AKZ; Cloutier G; Tang A; Rosado-Mendez IM; Rivaz H
IEEE Trans Ultrason Ferroelectr Freq Control; 2024 Mar; 71(3):354-365. PubMed ID: 38252581
[TBL] [Abstract][Full Text] [Related]
11. Optimization of the algorithms for estimating the ultrasonic attenuation along the propagation path.
Labyed Y; Bigelow TA
Ultrasonics; 2012 Aug; 52(6):720-9. PubMed ID: 22424697
[TBL] [Abstract][Full Text] [Related]
12. Fast linear least-squares method for ultrasound attenuation and backscatter estimation.
Birdi J; Muraleedharan A; D'hooge J; Bertrand A
Ultrasonics; 2021 Sep; 116():106503. PubMed ID: 34171752
[TBL] [Abstract][Full Text] [Related]
13. Innovative aberration correction in ultrasound diagnostics with direct phase estimation for enhanced image quality.
Leonov D; Kulberg N; Yakovleva T; Solovyova P; Costa-Júnior JFS; Saikia MJ
Phys Eng Sci Med; 2023 Dec; 46(4):1765-1778. PubMed ID: 37796368
[TBL] [Abstract][Full Text] [Related]
14. ESTIMATION METHOD OF THE HOMODYNED K-DISTRIBUTION BASED ON THE MEAN INTENSITY AND TWO LOG-MOMENTS.
Destrempes F; Porée J; Cloutier G
SIAM J Imaging Sci; 2013 Aug; 6(3):1499-1530. PubMed ID: 24795788
[TBL] [Abstract][Full Text] [Related]
15. Signal Subspace Smoothing Technique for Time Delay Estimation Using MUSIC Algorithm.
Sun M; Wang Y; Le Bastard C; Pan J; Ding Y
Sensors (Basel); 2017 Dec; 17(12):. PubMed ID: 29232868
[TBL] [Abstract][Full Text] [Related]
16. Physics-Inspired Regularized Pulse-Echo Quantitative Ultrasound: Efficient Optimization With ADMM.
Jafarpisheh N; Castaneda-Martinez L; Whitson H; Rosado-Mendez IM; Rivaz H
IEEE Trans Ultrason Ferroelectr Freq Control; 2023 Nov; 70(11):1428-1441. PubMed ID: 37782586
[TBL] [Abstract][Full Text] [Related]
17. H-scan analysis of thyroid lesions.
Ge GR; Laimes R; Pinto J; Guerrero J; Chavez H; Salazar C; Lavarello RJ; Parker KJ
J Med Imaging (Bellingham); 2018 Jan; 5(1):013505. PubMed ID: 29430475
[TBL] [Abstract][Full Text] [Related]
18. Correction: Investigation of a method to estimate the average speed of sound using phase variances of element signals for ultrasound compound imaging.
Nagaoka R; Omura M; Hasegawa H
J Med Ultrason (2001); 2024 Apr; ():. PubMed ID: 38568293
[No Abstract] [Full Text] [Related]
19. Task-oriented comparison of power spectral density estimation methods for quantifying acoustic attenuation in diagnostic ultrasound using a reference phantom method.
Rosado-Mendez IM; Nam K; Hall TJ; Zagzebski JA
Ultrason Imaging; 2013 Jul; 35(3):214-34. PubMed ID: 23858055
[TBL] [Abstract][Full Text] [Related]
20.
; ; . PubMed ID:
[No Abstract] [Full Text] [Related]
[Next] [New Search]