104 related articles for article (PubMed ID: 20085570)
21. Arteriovenous fistulas aggravate the hemodynamic effect of vein bypass stenoses: an in vitro study.
Nielsen TG; Djurhuus C; Pedersen EM; Laustsen J; Hasenkam JM; Schroeder TV
J Vasc Surg; 1996 Dec; 24(6):1043-9. PubMed ID: 8976359
[TBL] [Abstract][Full Text] [Related]
22. Hemodynamic impact of vein graft stenoses and their prediction in the vascular laboratory.
Belkin M; Schwartz LB; Donaldson MC; Mannick JA; Whittemore AD
J Vasc Surg; 1997 Jun; 25(6):1016-21; discussion 1022. PubMed ID: 9201162
[TBL] [Abstract][Full Text] [Related]
23. The native arteriovenous fistula in 2007. Surveillance and monitoring.
Besarab A; Asif A; Roy-Chaudhury P; Spergel LM; Ravani P
J Nephrol; 2007; 20(6):656-67. PubMed ID: 18046667
[TBL] [Abstract][Full Text] [Related]
24. Influence of luminal diameters on flow surveillance of hemodialysis grafts: insights from a mathematical model.
White JJ; Ram SJ; Jones SA; Schwab SJ; Paulson WD
Clin J Am Soc Nephrol; 2006 Sep; 1(5):972-8. PubMed ID: 17699315
[TBL] [Abstract][Full Text] [Related]
25. Intimal hyperplasia and hemodynamic factors in arterial bypass and arteriovenous grafts: a review.
Haruguchi H; Teraoka S
J Artif Organs; 2003; 6(4):227-35. PubMed ID: 14691664
[TBL] [Abstract][Full Text] [Related]
26. A large-scale study of the upper arm basilic transposition for hemodialysis.
Glass C; Porter J; Singh M; Gillespie D; Young K; Illig K
Ann Vasc Surg; 2010 Jan; 24(1):85-91. PubMed ID: 19631499
[TBL] [Abstract][Full Text] [Related]
27. Inflow stenoses in dysfunctional hemodialysis access fistulae and grafts.
Duijm LE; Liem YS; van der Rijt RH; Nobrega FJ; van den Bosch HC; Douwes-Draaijer P; Cuypers PW; Tielbeek AV
Am J Kidney Dis; 2006 Jul; 48(1):98-105. PubMed ID: 16797391
[TBL] [Abstract][Full Text] [Related]
28. Validation of computational fluid dynamics-based analysis to evaluate hemodynamic significance of access stenosis.
Hoganson DM; Hinkel CJ; Chen X; Agarwal RK; Shenoy S
J Vasc Access; 2014; 15(5):409-14. PubMed ID: 24811588
[TBL] [Abstract][Full Text] [Related]
29. Bedside screening for fistula stenosis should be tailored to the site of the arteriovenous anastomosis.
Tessitore N; Bedogna V; Lipari G; Melilli E; Mantovani W; Baggio E; Lupo A; Mansueto G; Poli A
Clin J Am Soc Nephrol; 2011 May; 6(5):1073-80. PubMed ID: 21441125
[TBL] [Abstract][Full Text] [Related]
30. Dysfunction Screening in Experimental Arteriovenous Grafts for Hemodialysis Using Fractional-Order Extractor and Color Relation Analysis.
Wu MJ; Chen WL; Kan CD; Yu FM; Wang SC; Lin HH; Lin CH
Cardiovasc Eng Technol; 2015 Dec; 6(4):463-73. PubMed ID: 26577479
[TBL] [Abstract][Full Text] [Related]
31. Extracorporeal pressure monitoring and the detection of vascular access stenosis.
Kleinekofort W; Kraemer M; Rode C; Wizemann V
Int J Artif Organs; 2002 Jan; 25(1):45-50. PubMed ID: 11853071
[TBL] [Abstract][Full Text] [Related]
32. The StenTec gauge for measuring static intra-access pressure ratio (P(Ia Ratio) ) of fistulas and grafts.
Ash SR; Dhamija R; Zaroura MY; Hentschel DM
Semin Dial; 2012 Jul; 25(4):474-81. PubMed ID: 22356546
[TBL] [Abstract][Full Text] [Related]
33. A method for monitoring vascular access function during hemodialysis.
Ciandrini A; Lodi CA; Galato R; Miscia MC; Fattori MS; Cavalcanti S
Kidney Int; 2009 Mar; 75(5):550-7. PubMed ID: 19052534
[TBL] [Abstract][Full Text] [Related]
34. The key role of color Doppler ultrasound in the work-up of hemodialysis vascular access.
Lomonte C; Meola M; Petrucci I; Casucci F; Basile C
Semin Dial; 2015; 28(2):211-5. PubMed ID: 25264303
[TBL] [Abstract][Full Text] [Related]
35. Hemodynamic impact of anastomosis size and angle in side-to-end arteriovenous fistulae: a computer analysis.
Van Canneyt K; Pourchez T; Eloot S; Guillame C; Bonnet A; Segers P; Verdonck P
J Vasc Access; 2010; 11(1):52-8. PubMed ID: 20119922
[TBL] [Abstract][Full Text] [Related]
36. Experimental analysis of the hemodynamics in punctured vascular access grafts.
Van Tricht I; De Wachter D; Tordoir J; Vanhercke D; Verdonck P
ASAIO J; 2005; 51(4):352-9. PubMed ID: 16156298
[TBL] [Abstract][Full Text] [Related]
37. New predictive marker for hemodialysis vascular access dysfunction.
Kim JD; Bae JI; Won JH; Lee JH; Oh CK; Jung H; Lee HY
Semin Dial; 2014; 27(1):61-7. PubMed ID: 24028825
[TBL] [Abstract][Full Text] [Related]
38. The flow field near a venous needle in hemodialysis: a computational study.
Fulker D; Kang M; Simmons A; Barber T
Hemodial Int; 2013 Oct; 17(4):602-11. PubMed ID: 23448433
[TBL] [Abstract][Full Text] [Related]
39. New hemodynamic test for assessment of failing hemodialysis grafts: the saline infusion test.
Werdick GM; Kruse JR; Cragg AH
J Vasc Interv Radiol; 2000 Feb; 11(2 Pt 1):171-5. PubMed ID: 10716386
[TBL] [Abstract][Full Text] [Related]
40. Mathematical model for pressure losses in the hemodialysis graft vascular circuit.
Jones SA; Jin S; Kantak A; Bell DA; Paulson WD
J Biomech Eng; 2005 Feb; 127(1):60-6. PubMed ID: 15868789
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]